A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics

被引:9
|
作者
Farago, Paul [1 ]
Grama, Lacrimioara [1 ]
Farago, Monica-Adriana [2 ]
Hintea, Sorin [1 ]
机构
[1] Tech Univ Cluj Napoca, Fac Telecommun & Informat Technol, Bases Elect Dept, Elect, Cluj Napoca 400114, Romania
[2] Univ Oradea, Fac Med & Pharm, Psychoneurosci & Rehabil Dept, Oradea 410087, Romania
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
关键词
EMG; resistive pressure sensor; footprint; center of pressure progression line; microcontroller; smart-shoe; cross-correlation; gait analysis; gait physiology; gait biomechanics; GASTROCNEMIUS; BALANCE; SOLEUS; KINEMATICS; PARAMETERS; MUSCLES; MODELS; OXFORD; FORCE;
D O I
10.3390/app11010268
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application: A wearable monitoring system for the assessment of walking physiology. Walking is the most basic form of human activity for achieving mobility. As an essential function of the human body, the examination of walking is directed towards the assessment of body mechanics in posture and during movement. This work proposes a wearable smart system for the monitoring and objective evaluation of foot biomechanics during gait. The proposed solution assumes the cross-correlation of the plantar pressure with lower-limb muscular activity, throughout the stance phase of walking. Plantar pressure is acquired with an array of resistive pressure sensors deployed onto a shoe insole along the center of gravity progression line. Lower-limb muscular activity is determined from the electromyogram of the tibialis anterior and gastrocnemius lower limb muscles respectively. Under this scenario, physiological gait assumes the interdependency of plantar pressure on the heel area with activation of the tibialis anterior, as well as plantar pressure on the metatarsal arch/toe area with activation of the gastrocnemius. As such, assessment of gait physiology is performed by comparison of a gait map, formulated based on the footprint-lower-limb muscle cross-correlation results, to a reference gait template. A laboratory proof of concept validates the proposed solution in a test scenario which assumes a normal walking and two pathological walking patterns.
引用
收藏
页码:1 / 29
页数:31
相关论文
共 50 条
  • [41] Total ankle arthroplasty and ankle arthrodesis affect the biomechanics of the inner foot differently
    Wang, Yan
    Wong, Duo Wai-Chi
    Tan, Qitao
    Li, Zengyong
    Zhang, Ming
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [42] Clinical validation of a system for the analysis of pediatric foot and ankle kinematics during gait
    Sampath, G
    Abu-Faraj, ZO
    Smith, PA
    Harris, GF
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2418 - 2421
  • [43] Total ankle arthroplasty and ankle arthrodesis affect the biomechanics of the inner foot differently
    Yan Wang
    Duo Wai-chi Wong
    Qitao Tan
    Zengyong Li
    Ming Zhang
    Scientific Reports, 9
  • [44] Wearable Gait Logging System Attached on Ankles to Estimate Foot Steps and Trajectories
    Kato, Yoshihiro
    Nagano, Hikaru
    Konyo, Masashi
    Tadokoro, Satoshi
    2017 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2017, : 294 - 299
  • [45] Relationships among subjective patient-reported outcome, quality of life, and objective gait characteristics using wearable foot inertial-sensor assessment in foot–ankle patients
    Chayanin Angthong
    Andrea Veljkovic
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 683 - 687
  • [46] Effects of the ankle angle of an ankle foot orthosis on foot pressure during the gait in healthy adults
    Chang, Jong-Sung
    Lee, Hae-Yong
    Kim, Myoung-Kwon
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (04) : 1033 - 1035
  • [47] Assessment of the Suitability of the Motorized Ankle-Foot Orthosis as a Diagnostic and Rehabilitation Tool for Gait
    Asin, Guillermo
    Barroso, Filipe A.
    Moreno, Juan C.
    Pons, Jose L.
    NEUROTECHNIX: PROCEEDINGS OF THE INTERNATIONAL CONGRESS ON NEUROTECHNOLOGY, ELECTRONICS AND INFORMATICS, 2013, : 161 - 166
  • [48] A wearable pneumatic-piezoelectric system for quantitative assessment of skeletomuscular biomechanics
    Gao, Dace
    Lee, Jin Pyo
    Chen, Jian
    Tay, Lei Shan
    Xin, Yangyang
    Parida, Kaushik
    Tan, Matthew Wei Ming
    Huang, Peiwen
    Kong, Keng He
    Lee, Pooi See
    DEVICE, 2024, 2 (03):
  • [49] An Easy Wearable Gait Assessment System for Assessing Stroke Patients
    Tseng, Mu-Hsun
    Chen, Tain-Song
    Chang, Ya-Ting
    2020 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2020), 2021, : 209 - 211
  • [50] Wearable System for Gait Assessment during Physical Rehabilitation Process
    Postolache, Octavian
    Girao, Pedro Silva
    Pereira, Jose M. D.
    Postolache, Gabriela
    2015 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2015, : 321 - 326