Efficacy of non-breath-hold magnetic resonance cholangiography at midfield strength

被引:0
|
作者
Govil, S [1 ]
Justus, A
Korah, I
Cherian, R
Chacko, A
机构
[1] Christian Med Coll & Hosp, Dept Radiol, Vellore 632004, Tamil Nadu, India
[2] Christian Med Coll & Hosp, Dept Gastroenterol, Vellore 632004, Tamil Nadu, India
关键词
magnetic resonance cholangiography; magnetic resonance cholangio-pancreatography;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The efficacy of non-breath-hold magnetic resonance (MR) cholangiography at mid-field strength (0.5 Tesla) was evaluated for delineating biliary anatomy and the cause and extent of biliary obstruction. We performed 65 MR cholangiograms on a mid-held 0.5 Tesla MR unit and correlated them with contrast cholangiography and/or surgery. MR cholangiography was found to be both sensitive and specific in the detection of biliary obstruction and in the definition of its cause (sensitivity 98%, specificity 100%, positive predictive value 100%, negative predictive value 85.7%, accuracy 98%), MR cholangiography accurately predicted the level of obstruction in 94 per cent of strictures. Normal caliber intra-hepatic biliary radicles were visualised in only 6 percent of the MR cholangiograms. In contrast, 94 per cent of dilated intrahepatic. biliary radicles were demonstrated. The confluence, and right and left hepatic ducts were visualized in 98 percent; the gall bladder in 65 percent; the cystic duct in 45 percent and the cystic duct insertion in 25 per cent. The extrahepatic bile duct was seen In 82.7 percent. A normal caliber pancreatic duct was seen in 18 percent while a dilated pancreatic duct was seen in 86 percent. The pancreatico-biliary junction was visualised in 7 percent. Non-breath-hold MR cholangiography at mid-field strength is a highly accurate method of evaluating the cause and level of biliary obstruction, comparable to high-field MR cholangiography. The spatial resolution however is inadequate for the detection of variations in biliary or pancreatic ductal anatomy when the ducts are of normal caliber.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [21] Multiplatform, Non-Breath-Hold Fast Scanning Protocols: Should We Stop Giving Breath-Hold Instructions for Routine Chest CT?
    Doda Khera, Ruhani
    Nitiwarangkul, Chayanin
    Singh, Ramandeep
    Homayounieh, Fatemeh
    Digumarthy, Subba R.
    Kalra, Mannudeep K.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2021, 72 (03): : 505 - 511
  • [22] INTER- AND INTRAFRACTION VARIABILITY IN LIVER POSITION IN NON-BREATH-HOLD STEREOTACTIC BODY RADIOTHERAPY
    Case, Robert B.
    Sonke, Jan-Jakob
    Moseley, Douglas J.
    Kim, John
    Brock, Kristy K.
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 302 - 308
  • [23] Comparison of single-breath-hold fast spin-echo sequences with routine non-breath-hold techniques: Application to MRI of renal masses
    Melki, PS
    Argaud, C
    Suminski, M
    Helenon, O
    Belin, X
    Millet, P
    Chretien, Y
    Zannoli, G
    Moreau, JF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 608 - 614
  • [24] Assessment of myocardial function with interactive non-breath-hold real-time MR imaging:: Comparison with echocardiography and breath-hold cine MR imaging
    Kühl, HP
    Spuentrup, E
    Wall, A
    Franke, A
    Schröder, J
    Heussen, N
    Hanrath, P
    Günther, RW
    Buecker, A
    RADIOLOGY, 2004, 231 (01) : 198 - 207
  • [25] Erythropoietic responses to a series of repeated maximal dynamic and static apnoeas in elite and non-breath-hold divers
    Elia, Antonis
    Barlow, Matthew J.
    Deighton, Kevin
    Wilson, Oliver J.
    O'Hara, John P.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (11-12) : 2557 - 2565
  • [26] Non-breath-hold gadolinium-enhanced MR angiography of the thoracoabdominal aorta: Experience in 18 children
    Lam, WWM
    Chan, JHM
    Hui, Y
    Chan, FL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 478 - 480
  • [27] Erythropoietic responses to a series of repeated maximal dynamic and static apnoeas in elite and non-breath-hold divers
    Antonis Elia
    Matthew J. Barlow
    Kevin Deighton
    Oliver J. Wilson
    John P. O’Hara
    European Journal of Applied Physiology, 2019, 119 : 2557 - 2565
  • [28] Efficacy of diagnosis of mechanical cholestasis by magnetic resonance cholangiography
    Urban, M
    Holzer, B
    Sebesta, C
    Schmid, L
    Schiessel, R
    Hruby, W
    Rosen, HR
    WORLD JOURNAL OF SURGERY, 2002, 26 (03) : 353 - 358
  • [29] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [30] Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT
    Suga, K.
    Yasuhiko, K.
    Iwanaga, H.
    Tokuda, O.
    Matsunaga, N.
    ACTA RADIOLOGICA, 2009, 50 (01) : 34 - 41