Efficacy of non-breath-hold magnetic resonance cholangiography at midfield strength

被引:0
|
作者
Govil, S [1 ]
Justus, A
Korah, I
Cherian, R
Chacko, A
机构
[1] Christian Med Coll & Hosp, Dept Radiol, Vellore 632004, Tamil Nadu, India
[2] Christian Med Coll & Hosp, Dept Gastroenterol, Vellore 632004, Tamil Nadu, India
关键词
magnetic resonance cholangiography; magnetic resonance cholangio-pancreatography;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The efficacy of non-breath-hold magnetic resonance (MR) cholangiography at mid-field strength (0.5 Tesla) was evaluated for delineating biliary anatomy and the cause and extent of biliary obstruction. We performed 65 MR cholangiograms on a mid-held 0.5 Tesla MR unit and correlated them with contrast cholangiography and/or surgery. MR cholangiography was found to be both sensitive and specific in the detection of biliary obstruction and in the definition of its cause (sensitivity 98%, specificity 100%, positive predictive value 100%, negative predictive value 85.7%, accuracy 98%), MR cholangiography accurately predicted the level of obstruction in 94 per cent of strictures. Normal caliber intra-hepatic biliary radicles were visualised in only 6 percent of the MR cholangiograms. In contrast, 94 per cent of dilated intrahepatic. biliary radicles were demonstrated. The confluence, and right and left hepatic ducts were visualized in 98 percent; the gall bladder in 65 percent; the cystic duct in 45 percent and the cystic duct insertion in 25 per cent. The extrahepatic bile duct was seen In 82.7 percent. A normal caliber pancreatic duct was seen in 18 percent while a dilated pancreatic duct was seen in 86 percent. The pancreatico-biliary junction was visualised in 7 percent. Non-breath-hold MR cholangiography at mid-field strength is a highly accurate method of evaluating the cause and level of biliary obstruction, comparable to high-field MR cholangiography. The spatial resolution however is inadequate for the detection of variations in biliary or pancreatic ductal anatomy when the ducts are of normal caliber.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF A NON-BREATH-HOLD MR CHOLANGIOGRAPHY TECHNIQUE
    MACAULAY, SE
    SCHULTE, SJ
    SEKIJIMA, JH
    OBREGON, RG
    SIMON, HE
    ROHRMANN, CA
    FREENY, PC
    SCHMIEDL, UP
    RADIOLOGY, 1995, 196 (01) : 227 - 232
  • [2] Non-breath-hold lung magnetic resonance imaging with real-time navigation
    Schmidt, MA
    Yang, GZ
    Keegan, J
    Jhooti, P
    Gatehouse, PD
    Carr, DH
    Hansell, DM
    Firmin, DN
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1997, 5 (02) : 123 - 128
  • [3] Non-breath-hold lung magnetic resonance imaging with real-time navigation
    M. A. Schmidt
    G. Z. Yang
    J. Keegan
    P. Jhooti
    P D. Gatehouse
    D. H. Carr
    D. M. Hansell
    D. N. Firmin
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1997, 5 : 123 - 128
  • [4] Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold
    Michael A. Bolen
    Randolph M. Setser
    Ruvin S. Gabriel
    Rahul D. Renapurkar
    Yasmeen Tandon
    Michael L. Lieber
    Milind Y. Desai
    Scott D. Flamm
    The International Journal of Cardiovascular Imaging, 2013, 29 : 113 - 120
  • [5] Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold
    Bolen, Michael A.
    Setser, Randolph M.
    Gabriel, Ruvin S.
    Renapurkar, Rahul D.
    Tandon, Yasmeen
    Lieber, Michael L.
    Desai, Milind Y.
    Flamm, Scott D.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 113 - 120
  • [6] Usefulness of non-breath-hold one shot magnetic resonance cholangiopancreatography for the evaluation of choledochal cyst in children
    不详
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 41 (04): : 551 - 552
  • [7] Diagnostic efficacy of non-breath hold magnetic resonance cholangiopancreatography
    Kuo, YT
    Jaw, TS
    Wang, CK
    Lee, LW
    Shen, PC
    Liu, GC
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1999, 98 (02) : 97 - 103
  • [8] Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system
    Goo, Eun-Hoe
    Kim, Sun-Ju
    Dong, Kyung-Rae
    Kim, Kwang-Choul
    Chung, Woon-Kwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (05) : 863 - 867
  • [9] Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system
    Eun-Hoe Goo
    Sun-Ju Kim
    Kyung-Rae Dong
    Kwang-Choul Kim
    Woon-Kwan Chung
    Journal of the Korean Physical Society, 2016, 69 : 863 - 867
  • [10] Evaluation of arch vessels: Breath-hold versus non-breath-hold techniques
    Krinsky, G
    RADIOLOGY, 2004, 232 (01) : 303 - 304