The impact of hydrogel lens settling on the thickness of the tears and contact lens

被引:34
|
作者
Nichols, JJ [1 ]
King-Smith, PE [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43218 USA
关键词
D O I
10.1167/iovs.04-0149
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the effect of contact lens insertion on the thickness on the prelens tear film (PLTF), the contact lens, and the postlens tear film (PoLTF). METHODS. Twelve contact lens wearers (mean age, 32.7 years; four males) inserted etafilcon A hydrogel lenses (power: -2.00 D, base curve: 8.3 mm) in both eyes immediately before testing. Previously described interference techniques, based on oscillations in reflectance spectra, were used to measure the thickness of the PLTF, contact lens, and PoLTF. The thickness of the layers is derived from the frequency of the oscillations. Spectra were captured 1 minute after lens insertion and every minute thereafter for 30 minutes. Least squares regression fits were used to determine the relation between thickness of each layer and time. RESULTS. The combined data from all subjects for PLTF thickness were fit with an exponential decay plus a constant thickness; the initial thickness was 4.5 micrometers, the time constant was 7.1 minutes (P < 0.001), and final thickness was 2.5 micrometers. The apparent thickness of the contact lens declined linearly at an average rate of 0.051 micrometers/minute (P < 0.001). The PoLTF thickness remained constant at 2.5 micrometers (P = 0.46). CONCLUSIONS. For most subjects, the PLTF thinned significantly over the course of the first 30 minutes of lens wear. The apparent thinning of the contact lens may be caused by a real thinning of the lens, but also may have a contribution from improved centration over the 30-minute period. The PoLTF remained relatively stable during this period.
引用
收藏
页码:2549 / 2554
页数:6
相关论文
共 50 条
  • [41] Phospholipids and their degrading enzyme in the tears of soft contact lens wearers
    Yamada, Masakazu
    Mochizuki, Hiroshi
    Kawashima, Motoko
    Hata, Seiichiro
    CORNEA, 2006, 25 (10) : S68 - S72
  • [42] Elemental Composition at Silicone Hydrogel Contact Lens Surfaces
    Rex, Jessica
    Knowles, Timothy
    Zhao, Xueying
    Lemp, Jessie
    Maissa, Cecile
    Perry, Scott S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S221 - S226
  • [43] Applanation tonometry in silicone hydrogel contact lens wearers
    Allen, RJ
    De Wit, D
    Saleh, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U576 - U576
  • [44] Plasmonic contact lens materials for glucose sensing in human tears
    Lee, Won-Chul
    Koh, Eun Hye
    Kim, Dong-Ho
    Park, Sung-Gyu
    Jung, Ho Sang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 344
  • [45] THE SPECTRAL TRANSMITTANCE OF HYDROGEL CONTACT-LENS FILTERS
    ABADI, RV
    DAVIES, IP
    PAPAS, E
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1989, 9 (04) : 360 - 367
  • [46] Contact Lens-Induced Discomfort and Protein Changes in Tears
    Masoudi, Simin
    Stapleton, Fiona Jane
    Willcox, Mark Duncan Perry
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) : 955 - 962
  • [47] VEGF levels in the tears of soft contact lens wearers.
    Magone, T
    Strauss, EC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U579 - U579
  • [48] Interleukin-6 levels in tears of contact lens wearers
    Schultz, CL
    Kunert, KS
    JOURNAL OF INTERFERON AND CYTOKINE RESEARCH, 2000, 20 (03): : 309 - 310
  • [49] OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
    Garcia-Lazaro, Santiago
    Madrid-Costa, David
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (01) : 62 - 69
  • [50] Antifouling Studies of Lehfilcon A Silicone Hydrogel Contact Lens
    Liang, Shuang
    Shows, Amanda
    Dunbar, Daniel
    Sharma, Vinay
    Shi, Charlie Xinfeng
    Wu, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)