RADON CONCENTRATIONS IN MULTI-STORY BUILDINGS IN MONTENEGRO

被引:4
|
作者
Vukotic, Perko [1 ]
Zekic, Ranko [2 ]
Antovic, Nevenka M. [3 ]
Andjelic, Tomislav [2 ]
机构
[1] Montenegrin Acad Sci & Arts, Podgorica, Montenegro
[2] Ctr Ecotoxicol Res, Podgorica, Montenegro
[3] Univ Montenegro, Fac Nat Sci & Math, Podgorica, Montenegro
来源
关键词
multi-story building; year-long radon measurement; change of radon concentration with floor level;
D O I
10.2298/NTRP181108020V
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Change of radon concentrations in dwellings with floor level was studied in six multi-story buildings, in four towns of Montenegro with different climate conditions. The annual average radon activity concentrations in 35 dwellings are found to be very low, mostly at a level of 20-30 Bqm(-3). Absorbed gamma dose rates in these dwellings are in the range of 14-58 nGyh(-1). The low radon concentrations are a consequence of a good tightness of the structures in contact with the ground and a small contribution of building materials to radon indoors. A clear general trend of changes in radon concentrations with floor level is not observed. In most of the dwellings on different floors in the multi-story building radon concentration varies very little, mostly within measurement error. A small decrease in radon concentration is noted between the two or three floors closest to the ground, but only in some of the buildings. Therefore, a decrease of indoor radon concentration with floor level cannot be considered as a general characteristic of multi-story buildings. Although the seasonal radon variations have not been in the focus of this study, it was found that the average radon activity concentrations in dwellings of the multi-story buildings are higher in warmer than in cooler half-year period, what is contrary to the general rule for homes in the world and in Montenegro as well.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 50 条
  • [21] Seismic Loads on Two- and Multi-Story Buildings.
    Rosman, Riko
    Beton- und Stahlbetonbau, 1984, 79 (08) : 201 - 208
  • [22] Earthquake evacuation simulation of multi-story buildings during earthquakes
    He, Jun
    EARTHQUAKE SPECTRA, 2021, 37 (01) : 95 - 113
  • [23] Optimum relief force of oil dampers in multi-story buildings
    Tsuji, Masaaki
    Tanaka, Hidetoshi
    Yoshitomi, Shinta
    Takewaki, Izuru
    Journal of Structural and Construction Engineering, 2012, 77 (678): : 1237 - 1246
  • [24] An efficient modeling technique for floor vibration in multi-story buildings
    Lee, DG
    Ahn, SK
    Kim, J
    STRUCTURAL ENGINEERING AND MECHANICS, 2000, 10 (06) : 603 - 619
  • [25] Injection Grouting Preserves Foundation Integrity of Multi-Story Buildings
    Babcock, Britt N.
    GROUTING 2017: CASE HISTORIES, 2017, (287): : 175 - 183
  • [26] Introduction of an Innovative Cladding Panel System for Multi-Story Buildings
    Maneetes, Hathairat
    Memari, Ali M.
    BUILDINGS, 2014, 4 (03) : 418 - 436
  • [27] Omnidirectional liquid column vibration absorbers for multi-story buildings
    Mehrkian, Behnam
    Altay, Okyay
    JOURNAL OF BUILDING ENGINEERING, 2022, 62
  • [28] Practical Implementation of Structural Health Monitoring in Multi-Story Buildings
    Sivasuriyan, Arvindan
    Vijayan, Dhanasingh Sivalinga
    Gorski, Wojciech
    Wodzynski, Lukasz
    Vaverkova, Magdalena Daria
    Koda, Eugeniusz
    BUILDINGS, 2021, 11 (06)
  • [29] Multi-Story Volumetric Blocks Buildings with Lower Frame Floors
    Teshev, Ilia
    Bespayev, Aliy
    Zhambakina, Zauresh
    Tamov, Murat
    Altigenov, Ulan
    Zhussupov, Timur
    Tolegenova, Aigerim
    BUILDINGS, 2024, 14 (06)
  • [30] Identification and analysis of construction workspace conflicts in multi-story buildings
    Weizhuo, Lu
    Yaowu, Wang
    PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON CONSTRUCTION & REAL ESTATE MANAGEMENT, VOLS 1 AND 2, 2007, : 6 - 10