Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults

被引:9
|
作者
Cho, Yeon Jin [1 ]
Kim, Woo Sun [1 ,2 ,3 ]
Choi, Young Hun [1 ]
Lee, Seul Bi [1 ]
Lee, SeungHyun [1 ]
Cheon, Jung-Eun [1 ,2 ,3 ]
Paek, MunYoung [4 ]
Woo, SeungTae [5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, 103 Daehak Ro, Seoul 03080, South Korea
[4] Siemens Healthcare Ltd, 23 Chungjeong Ro, Seoul 03737, South Korea
[5] Radiol Bayer Korea Ltd, 23 Boramae Ro, Seoul 07071, South Korea
关键词
INVERSION-RECOVERY MOLLI; HEPATIC-FIBROSIS; RELAXATION-TIME; MR RELAXOMETRY; CIRRHOSIS;
D O I
10.1038/s41598-020-74717-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated the feasibility of free-breathing modified Look-Locker inversion recovery (MOLLI) sequence for measuring hepatic T1 values in children and young adults. To investigate the accuracy and the reproducibility of the T1 maps, a phantom study was performed with 12 different gadoterate meglumine concentrations and the T1 relaxation times of phantoms measured with the MOLLI sequence were compared against those measured with three different sequences: spin-echo inversion recovery, variable flip angle (VFA), and VFA with B1 correction. To evaluate the feasibility of freebreathing MOLLI sequence, hepatic T1 relaxation times obtained by free-breathing and breath-hold technique in twenty patients were compared. The phantom study revealed the excellent accuracy and reproducibility of MOLLI. In twenty patients, the mean value of hepatic T1 values obtained by free-breathing (606.7 +/- 64.5 ms) and breath-hold (609.8 +/- 64.0 ms) techniques showed no significant difference (p > 0.05). The Bland-Altman plot between the free-breathing and breath-hold revealed that the mean difference of T1 values was - 3.0 ms (- 0.5%). Therefore, T1 relaxation times obtained by MOLLI were comparable to the values obtained using the standard inversion recovery method. The hepatic T1 relaxation times measured by MOLLI technique with free-breathing were comparable to those obtained with breath-hold in children and young adults.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Zhenfeng Lyu
    Sha Hua
    Jian Xu
    Yiwen Shen
    Rui Guo
    Peng Hu
    Haikun Qi
    Journal of Cardiovascular Magnetic Resonance, 25
  • [42] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Lyu, Zhenfeng
    Hua, Sha
    Xu, Jian
    Shen, Yiwen
    Guo, Rui
    Hu, Peng
    Qi, Haikun
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [43] Effect of changes to Modified Look-Locker Inversion (MOLLI) sequence on T1 Mapping at 3.0 Tesla in healthy volunteers
    Adam K McDiarmid
    David M Higgins
    David P Ripley
    Akhlaque Uddin
    Ananth Kidambi
    Peter P Swoboda
    Tarique A Musa
    Bara Erhayiem
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [44] Characterization of Benign Myocarditis Using Quantitative Delayed-Enhancement Imaging Based on Molli T1 Mapping
    Toussaint, Marcel
    Gilles, Raymond J.
    Azzabou, Noura
    Marty, Benjamin
    Vignaud, Alexandre
    Greiser, Andreas
    Carlier, Pierre G.
    MEDICINE, 2015, 94 (43)
  • [45] Systolic MOLLI T1 mapping with heart rate depends pulse sequence sampling scheme is feasible in patients with atrial fibrillation
    Xiaohai Ma
    Lei Zhao
    Tianjing Zhang
    Jing An
    Andreas Greiser
    Zhanming Fan
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [46] Potential of Liver T1 Mapping for the Detection of Fontan-associated Liver Disease in Adults
    Shiina, Yumi
    Inai, Kei
    Ohashi, Ryoko
    Nagao, Michinobu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (03) : 295 - 302
  • [47] Comparison of myocardial T1 mapping during breath-holding and free-breathing
    Oka, Hideharu
    Nakau, Kouichi
    Nakagawa, Sadahiro
    Kobayashi, Yuki
    Imanishi, Rina
    Iwata, Kunihiro
    Azuma, Hiroshi
    CARDIOLOGY IN THE YOUNG, 2022, 32 (06) : 925 - 929
  • [48] Integrated motion correction and dictionary learning for free-breathing myocardial T1 mapping
    Zhu, Yanjie
    Kang, Jinkyu
    Duan, Chong
    Nezafat, Maryam
    Neisius, Ulf
    Jang, Jihye
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2644 - 2654
  • [49] 3D saturation recovery imaging for free breathing myocardial T1 mapping
    Markus Henningsson
    Rene M Botnar
    Tobias Voigt
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [50] Systolic MOLLI T1 mapping with heart-rate-dependent pulse sequence sampling scheme is feasible in patients with atrial fibrillation
    Zhao, Lei
    Li, Songnan
    Ma, Xiaohai
    Greiser, Andreas
    Zhang, Tianjing
    An, Jing
    Bai, Rong
    Dong, Jianzeng
    Fan, Zhanming
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18