Measurement of parameters of tracks in CR-39 detector from replicas

被引:12
|
作者
Yu, KN [1 ]
Ng, FMF [1 ]
Ho, JPY [1 ]
Yip, CWY [1 ]
Nikezic, D [1 ]
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1093/rpd/nch367
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In determining the etched track rate in solid-state nuclear track detectors, track lengths should be determined accurately. A method based on surface profilometry is proposed to determine the track lengths in CR-39 detectors through measurements of their replicas. Tracks from alpha particles with an incident energy of 4 MeV have been chosen to demonstrate the method. After irradiation and chemical etching, resin replicas were made from the tracks, of which the heights were measured by the Form Talysurf PGI Profilometer. The results showed that the surface of the replicas were smooth and the heights of the replicas were uniform, so the replicating fluid should have filled the tracks completely and the replicas truly reflected the dimensions of the tracks. The heights of the replicas were conveniently determined from the lateral view of the replicas generated by the Form Talysurf PGI Profilometer.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 50 条
  • [11] Field measurement of radon exhalation rate from the soil by CR-39 detector
    A. Vasidov
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 919 - 923
  • [12] Studies on the nuclear tracks in CR-39 plastics
    Yamauchi, T
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 73 - 81
  • [13] Annealing of fission fragment tracks in CR-39 nuclear track detector - Phenomenological model
    Rana, Mukhtar Ahmed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 40 - 44
  • [14] RADIOGRAPHIC CHARACTERISTICS OF CR-39 DETECTOR
    ILIC, R
    NAJZER, M
    PODGORNIK, A
    HUMAR, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 351 - 351
  • [15] V-function to investigate tracks of the alpha particle irradiated CR-39 detector
    Al-Jubbori, Mushtaq Abed
    RADIATION MEASUREMENTS, 2020, 136 (136)
  • [16] MEASUREMENT OF THE ETCH CHARACTERISTICS OF PROTON TRACKS IN CR-39 AND THE IMPLICATIONS FOR NEUTRON DOSIMETRY
    HARVEY, JR
    RAMLI, AG
    WEEKS, AR
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 307 - 311
  • [17] APPLICATION OF CR-39 TRACK DETECTOR TO NEUTRON-SPECTRUM MEASUREMENT
    ODA, K
    ENCHO, H
    YONEDA, H
    MIYAKE, H
    URABE, I
    KOBAYASHI, K
    KIMURA, I
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1991, 28 (07) : 608 - 617
  • [18] Digital image analysis of the etched α-tracks in CR-39
    Simakin, I. S.
    Vlasova, I. E.
    Kalmykov, S. N.
    RADIATION MEASUREMENTS, 2013, 50 : 212 - 217
  • [19] Analysis of latent tracks for MeV protons in CR-39
    Kar, S.
    Borghesi, M.
    Romagnani, L.
    Takahashi, S.
    Zayats, A.
    Malka, V.
    Fritzler, S.
    Schiavi, A.
    JOURNAL OF APPLIED PHYSICS, 2007, 101 (04)