Monte Carlo systems used for treatment planning and dose verification

被引:4
|
作者
Brualla, Lorenzo [1 ]
Rodriguez, Miguel [2 ]
Lallena, Antonio M. [3 ]
机构
[1] Univ Klinikum Essen, NCTeam, Strahlenklin, Hufelandstr 55, D-45122 Essen, Germany
[2] Ctr Med Paitilla, Calle 53 & Ave, Balboa, Panama
[3] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
关键词
Photons; Electrons; Software; Algorithms; Radiation; VARIANCE-REDUCTION TECHNIQUES; ELECTRON-BEAM; PHASE-SPACE; MODULATED ELECTRON; CALCULATION TOOL; SOURCE MODEL; SIMULATION; PHOTON; RADIOTHERAPY; TRANSPORT;
D O I
10.1007/s00066-016-1075-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
General-purpose radiation transport Monte Carlo codes have been used for estimation of the absorbed dose distribution in external photon and electron beam radiotherapy patients since several decades. Results obtained with these codes are usually more accurate than those provided by treatment planning systems based on non-stochastic methods. Traditionally, absorbed dose computations based on general-purpose Monte Carlo codes have been used only for research, owing to the difficulties associated with setting up a simulation and the long computation time required. To take advantage of radiation transport Monte Carlo codes applied to routine clinical practice, researchers and private companies have developed treatment planning and dose verification systems that are partly or fully based on fast Monte Carlo algorithms. This review presents a comprehensive list of the currently existing Monte Carlo systems that can be used to calculate or verify an external photon and electron beam radiotherapy treatment plan. Particular attention is given to those systems that are distributed, either freely or commercially, and that do not require programming tasks from the end user. These systems are compared in terms of features and the simulation time required to compute a set of benchmark calculations.
引用
收藏
页码:243 / 259
页数:17
相关论文
共 50 条
  • [11] Verification of a Monte Carlo-based treatment planning toot
    Chow, J.
    Leung, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S92 - S92
  • [12] Experimental verification of the Monte Carlo proton dose calculation algorithm VMCpro for the treatment planning of ocular tumors
    Fippel, M
    Soukup, M
    Weber, A
    Heufelder, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S64 - S65
  • [13] Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code
    Boiset, Gisell Ruiz
    Batista, Delano V. S.
    Cardoso, Simone Coutinho
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 1 - 10
  • [14] Verification for dose estimation performance of a Monte-Carlo based treatment planning system in University of Tsukuba
    Kumada, Hiroaki
    Takada, Kenta
    Aihara, Teruhito
    Matsumura, Akira
    Sakurai, Hideyuki
    Sakae, Takeji
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [15] A Monte Carlo evaluation of dose distribution of commercial treatment planning systems in heterogeneous media
    Hasani, Mohsen
    Mohammadi, Kheirollah
    Ghorbani, Mahdi
    Gholami, Soraya
    Knaup, Courtney
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 : S127 - S134
  • [16] THE USED OF COMPUTED TOMOGRAPHY IMAGES FOR MONTE CARLO TREATMENT PLANNING
    Bazalova, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S50 - S50
  • [17] Monte Carlo Dose Calculation for Clinical IMRT Treatment Planning
    Siebers, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [18] A Monte Carlo dose calculation tool for radiotherapy treatment planning
    Ma, CM
    Li, JS
    Pawlicki, T
    Jiang, SB
    Deng, J
    Lee, MC
    Koumrian, T
    Luxton, M
    Brain, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1671 - 1689
  • [19] Monte Carlo tool for combined photon and proton treatment planning verification
    Seco, J.
    Jiang, H.
    Herrup, D.
    Kooy, H.
    Paganetti, H.
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [20] Implementation of Monte Carlo Dose Calculation for CyberKnife treatment planning
    Ma, C-M
    Li, J. S.
    Deng, J.
    Fan, J.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102