Effect of Sensor-Augmented Pump Treatment Versus Multiple Daily Injections on Albuminuria: A 1-Year Randomized Study

被引:12
|
作者
Rosenlund, Signe [1 ,2 ]
Hansen, Tine Willum [1 ]
Rossing, Peter [1 ,3 ,4 ]
Andersen, Steen [2 ]
机构
[1] Steno Diabet Ctr, DK-2820 Gentofte, Denmark
[2] Nordsjaellands Hosp, DK-3400 Hillerod, Denmark
[3] Aarhus Univ, DK-8000 Aarhus C, Denmark
[4] Univ Copenhagen, DK-2200 Copenhagen N, Denmark
来源
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM | 2015年 / 100卷 / 11期
关键词
SUBCUTANEOUS INSULIN INFUSION; STRICT METABOLIC-CONTROL; GLYCEMIC VARIABILITY; FOLLOW-UP; MICROVASCULAR COMPLICATIONS; DIABETIC-NEPHROPATHY; SEVERE HYPOGLYCEMIA; KIDNEY-FUNCTION; GLUCOSE; PROGRESSION;
D O I
10.1210/jc.2015-2839
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: The effect of glycemic control on persisting albuminuria remains unclear. Insulin delivery and glucose variability may be important. Objective: This study aimed to investigate the effect of 1-year treatment with sensor-augmented insulin pump (SAP) or multiple daily injections (MDIs) on albuminuria. Design, Patients, and Methods: This was a randomized controlled open-label parallel trial composed of 60 patients with type 1 diabetes with a history of albuminuria and on stable reninangiotensin system inhibition, were randomly assigned to SAP or MDI. Urine albumin creatinine ratio (UACR) was measured in three urine samples at all visits. Glucose variability and glomerular filtration rate (Cr-51-EDTA-GFR) were measured at beginning and study end. Using linear mixed model, change in UACR between groups was analyzed as intention to treat. Main Outcome Measure: Change in UACR was measured. Results: Fifty-five patients (SAP, n = 26; MDI, n = 29) completed the study. Diabetes duration (mean +/- SD, 33 +/- 12 y), UACR (geometric mean, 99 mg/g; interquartile range, 37-233 mg/g), Cr-51-EDTA-GFR (94 +/- 22 mL/min/1.73m(2)), glycosylated hemoglobin (HbA(1c)) (9.0 +/- 1.1%), glucose variability (calculated as SD), 4.0 +/- 1.0 mmol/l; no-group differences (P > .06 for all). After 1 year, change in UACR was mean, -13%; 95% confidence interval, -39 to 22 with SAP vs mean, 30%; 95% CI, -12 to 92% on MDI treatment (unadjusted P = .051; adjusted for HbA(1c), P = .04). HbA(1c) decreased 1.3 +/- 1.0 vs 0.6 +/- 1.0% (P = .013), glucose variability decreased 0.9 +/- 1.1 vs 0.3 +/- 1.0 mmol/L (P = .04), and 51Cr-EDTA-GFR declined 5.6 +/- 9.6 vs 3.4 +/- 13 mL/min/1.73m(2) (P = .50) with SAP vs MDI treatment. There were no changes in blood pressure (P >= .27). Conclusion: SAP treatment reduced UACR in a randomized controlled trial in type 1 diabetes patients with a history of albuminuria on stable renin-angiotensin system inhibition. Significance was reached after adjustment. SAP treatment reduced HbA(1c) and glucose variability (calculated as SD).
引用
收藏
页码:4181 / 4188
页数:8
相关论文
共 50 条
  • [21] Experiences in Sensor-Augmented Pump Therapy in Families with two Children with Type 1 diabetes: A Qualitative Study
    Bomba, Franziska
    Mueller-Godeffroy, Esther
    von Sengbusch, Simone
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2018, 126 (03) : 162 - 167
  • [22] Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study
    Slover, Robert H.
    Welsh, John B.
    Criego, Amy
    Weinzimer, Stuart A.
    Willi, Steven M.
    Wood, Michael A.
    Tamborlane, William V.
    PEDIATRIC DIABETES, 2012, 13 (01) : 6 - 11
  • [23] Cost-effectiveness of sensor-augmented pump therapy versus standard insulin pump therapy in patients with type 1 diabetes in Denmark
    Roze, S.
    de Portu, S.
    Smith-Palmer, J.
    Delbaere, A.
    Valentine, W.
    Ridderstrale, M.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2017, 128 : 6 - 14
  • [24] PROLOG: A RANDOMIZED CLINICAL TRIAL TO ASSESS THE EFFICACY OF PREDICTIVE LOW GLUCOSE SUSPEND VERSUS SENSOR-AUGMENTED PUMP THERAPY IN THE MANAGEMENT OF TYPE 1 DIABETES
    Buckingham, B.
    Pinsker, J.
    Forlenza, G.
    Cengiz, E.
    Pettus, J.
    Swanson, V.
    Li, Z.
    Lum, J.
    Kollman, C.
    Beck, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A12 - A12
  • [25] Closed-Loop Insulin Delivery Versus Sensor-Augmented Pump Therapy in Older Adults With Type 1 Diabetes (ORACL): A Randomized, Crossover Trial
    McAuley, Sybil A. A.
    Trawley, Steven
    Vogrin, Sara
    Ward, Glenn M. M.
    Fourlanos, Spiros
    Grills, Charlotte A. A.
    Lee, Melissa H. H.
    Alipoor, Andisheh Mohammad
    O'Neal, David N. N.
    O'Regan, Niamh A. A.
    Sundararajan, Vijaya
    Colman, Peter G. G.
    MacIsaac, Richard J. J.
    DIABETES CARE, 2022, 45 (02) : 381 - 390
  • [26] Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes (The STAR 3 Study)
    Gimenez Alvarez, M.
    AVANCES EN DIABETOLOGIA, 2010, 26 (05): : 383 - 384
  • [27] GLYCAEMIC VARIABILITY AND TIME IN RANGE IN TYPE 1 DIABETES PATIENTS ON REAL TIME CONTINUOUS GLUCOSE MONITORING AND INSULIN INJECTIONS VERSUS SENSOR-AUGMENTED INSULIN PUMP THERAPY
    Beato-Vibora, P.
    Lazaro-Martin, L.
    Gallego-Gamero, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A93 - A93
  • [28] USE OF SENSOR-AUGMENTED INSULIN PUMP THERAPY: INCLUSION CRITERIA AND RESULTS AFTER 1 YEAR OF FOLLOW-UP
    Pazos-Couselo, M.
    Maria, G. R.
    Gude, F.
    Casanueva, F.
    Garcia-Lopez, J. M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A77 - A78
  • [29] Improved glucose control with sensor-augmented pump therapy in youth with type 1 diabetes and elevated HbA1c levels on multiple daily injection therapy in the STAR 3 Study
    Tamborlane, W. V.
    Slover, R.
    Criego, A.
    Daniels, M.
    Foster, C. M.
    McEvoy, R. C.
    Orlowski, C.
    Weinzimer, S.
    White, N.
    Willi, S. M.
    DIABETOLOGIA, 2010, 53
  • [30] Long-Term Effects of Sensor-Augmented Pump Therapy in Type 1 Diabetes: A 3-Year Follow-Up Study
    Schmidt, Signe
    Norgaard, Kirsten
    DIABETES, 2012, 61 : A3 - A3