Comparison of the accuracy of different impression procedures in case of multiple and angulated implants Accuracy of impressions in multiple and angulated implants

被引:20
|
作者
Richi, M. Wafa [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin10, Ankara, Turkey
关键词
ARCH;
D O I
10.1186/s13005-020-00225-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. Methods: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl polysiloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. Results: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). Conclusions: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 412 - 415
  • [42] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S412 - S415
  • [43] The Effect of Implant Connection Length on the Dimensional Impression Accuracy of Inclined Implants
    Ehsani, Sara
    Siadat, Hakimeh
    Alikhasi, Marzieh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E315 - E320
  • [44] Effect of an auxiliary device on scanning accuracy for multiple implants: an in vitro comparative study
    Mingyue Lyu
    Dingyi Xu
    Yizhou Li
    Shiwen Zhang
    Heling Zhao
    Quan Yuan
    Head & Face Medicine, 21 (1)
  • [45] Comparison of the accuracy of impressions made of 2 implants with interfering axial convergence with CAD-CAM impression copings and the altered cast technique: An in vitro study
    Sadegholvad, Maryam
    Ansarifard, Elham
    Derafshi, Reza
    Dehno, Seyede Mina Salehi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 745.e1 - 745.e7
  • [46] In vitro comparison of the accuracy of four intraoral scanners and three conventional impression methods for two neighboring implants
    Roig, Elena
    Garza, Luis Carlos
    Alvarez-Maldonado, Natalia
    Maia, Paulo
    Costa, Santiago
    Roig, Miguel
    Espona, Jose
    PLOS ONE, 2020, 15 (02):
  • [47] Custom Copings for Accurate Impressions of Multiple Internal Connection Implants
    Ntounis, Athanasios
    Pelekanos, Stauros
    IMPLANT DENTISTRY, 2010, 19 (05) : 365 - 369
  • [48] A laboratory investigation of the accuracy of two impression techniques for single-tooth implants
    Daoudi, MF
    Setchell, DJ
    Searson, LJ
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (02) : 152 - 158
  • [49] Accuracy of Impression Techniques with Maxillary Angled Implants Using Trays and Multifunctional Guides
    de Souza Bezerra Araujo, Raphael Ferreira
    Oliveira, Lucas Portela
    Arioli Filho, Joao Neudenir
    Mollo Junior, Francisco de Assis
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 530 - 537
  • [50] Assessment of impression material accuracy in complete-arch restorations on four implants
    Baldissara, Paolo
    Koci, Brunilda
    Messias, Aion Mangino
    Meneghello, Roberto
    Ghelli, Francesco
    Gatto, Maria Rosaria
    Ciocca, Leonardo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 763 - 771