A new calibration method for measuring acoustic transfer matrixes with flow and application to an automotive compressor

被引:0
|
作者
Rousseleta, Benoit [1 ]
Gibiat, Vincent [1 ]
Guilain, Stephane [2 ]
Lefebvre, Alain [2 ]
机构
[1] Univ Toulouse 3, Lab PHASE, F-31062 Toulouse 9, France
[2] Renault SAS, Powertrain Engn Div, FR CTL L16 1 29, F-91510 Lardy, France
关键词
PARAMETERS; IMPEDANCE;
D O I
10.1016/j.jsv.2014.06.042
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new method for measuring acoustic transfer matrixes with flow has been developed. It is based on two-load technique. Great improvements were obtained on specific calibration of the connections. We present here the calibration principles and validation. Measurements of basic resonating systems, first without flow then with flow up to Mach 0.2 clearly validated the accuracy of the technique, even under extreme flow conditions. This technique was developed to allow the determination of the acoustic behavior of an automotive engine intake line, comprising a compressor. Measurements of the transfer matrix of an automotive compressor are presented without flow then under realistic engine conditions. The results obtained are compared to those of a basic acoustic model of the compressor. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6370 / 6380
页数:11
相关论文
共 50 条
  • [41] Transfer element method with application to acoustic design of aeroengine nacelle
    Wang Xiaoyu
    Sun Xiaofeng
    Chinese Journal of Aeronautics, 2015, 28 (02) : 327 - 345
  • [42] A new method for measuring γ-ray energy at the internal calibration of a radioactive source
    Morozov, VA
    Zlokazov, VB
    Kalinin, AI
    Kalinnikov, VG
    Lebedev, NA
    Morozova, NV
    Churin, IN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2000, 43 (03) : 300 - 305
  • [43] A new method for measuring γ-ray energy at the internal calibration of a radioactive source
    V. A. Morozov
    V. B. Zlokazov
    A. I. Kalinin
    V. G. Kalinnikov
    N. A. Lebedev
    N. V. Morozova
    I. N. Churin
    Instruments and Experimental Techniques, 2000, 43 : 300 - 305
  • [44] A New NIR Calibration Transfer Method Based on Parameter Correction
    Hu Yun
    Li Bo-yan
    Zhang Jin
    Peng Qian-rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (06) : 1804 - 1808
  • [45] A new calibration transfer method based on target factor analysis
    Wang, YB
    Yuan, HF
    Lu, WZ
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (03) : 398 - 401
  • [46] A NEW METHOD OF MEASURING CORONARY BLOOD FLOW IN MAN
    BING, RJ
    COWAN, C
    BOTTCHER, D
    CORSINI, G
    DANIELS, CG
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 205 (05): : 277 - &
  • [47] New non-invasive flow measuring method
    Zhu, Hailin
    Zou, Jing
    Gao, Lanqing
    Zhang, Wenming
    Jixie Gongyishi/Machinery Manufacturing Engineer, (12): : 421 - 424
  • [48] NEW METHOD OF MEASURING AIR-FLOW IN DUCTWORK
    不详
    REFRIGERATION AND AIR CONDITIONING, 1976, 79 (943): : 32 - &
  • [49] A New Vibration Test Method for Automotive and Consumer Electronic Devices: Calibration and Fatigue Test
    Xie, Dongji
    Zhang, Andy
    Kelly, Brian
    Lee, Jeffrey
    Roucou, Romuald
    Shi, Xue
    Doranga, Sushil
    Khaldarov, Valeriy
    Hai, Joe
    2023 IEEE 73RD ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE, ECTC, 2023, : 289 - 296
  • [50] Application of the front tracking method in micro flow measuring devices
    Batista E.
    Sousa J.A.
    Álvares M.
    Afonso J.
    Martins R.F.
    Measurement: Sensors, 2022, 23