Preprocedural ECG-Gated Computed Tomography for Prevention of Complications during Lead Extraction

被引:29
|
作者
Lewis, Robert K. [1 ]
Pokorney, Sean D. [1 ]
Greenfield, Ruth Ann [1 ]
Hranitzky, Patrick M. [2 ]
Hegland, Donald D. [1 ]
Schroder, Jacob N. [3 ]
Lin, Shu S. [3 ]
Milano, Carmelo [3 ]
Daubert, James P. [1 ]
Smith, Peter K. [3 ]
Hurwitz, Lynne M. [4 ]
Piccini, Jonathan P. [1 ]
机构
[1] Duke Univ, Med Ctr, Duke Heart Ctr, Cardiac Electrophysiol Sect, Durham, NC 27710 USA
[2] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[3] Duke Univ, Med Ctr, Duke Heart Ctr, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
来源
关键词
cardiac electronic implantable device; lead extraction; computed tomography; ICD; pacemaker; UNITED-STATES; LASER SHEATH; EXPERIENCE;
D O I
10.1111/pace.12485
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPreprocedural multidetector computed tomography (MDCT) may identify patients at risk for mechanical complications during lead extraction. MethodsTo describe the use and feasibility of computed tomography scanning for preprocedural planning of lead extraction, we conducted a retrospective study of high-risk patients, who underwent electrocardiogram (ECG)-gated MDCT before planned lead extraction between January 1, 2012, and March 30, 2013. ResultsAmong 30 patients the mean age was 63 15 years, 60% were male, and 20% had prior sternotomy. Most devices were left sided (93%) and 24 had implantable defibrillators (80%). Indications for extraction included lead malfunction (n = 15; 50%), class I lead advisories (n = 11; 37%), and infection (n = 10; 33%). Overall, there were 65 leads extracted (mean 2.1 leads per patient). One extraction procedure was deferred due to MDCT evidence of significant myocardial perforation with the lead tip > 1 cm beyond the epicardium (n = 1, 3%). MDCT suggestion of lead adherence to central venous structures (n = 13, 43%) was associated with significantly longer laser times (88 +/- 71 seconds vs 30 +/- 37 seconds, P = 0.02) and larger sheath size (14.9 +/- 1.3 vs 13.5 +/- 1.2 French, P = 0.02). MDCT evidence of central venous occlusion or stenosis was not associated with increased laser times. Excluding the patient with MDCT evidence of significant perforation, clinical success was achieved in all patients (n = 29/29). ConclusionsECG-gated MDCT scanning before lead extraction may facilitate the identification of significant perforation and patients at high risk for mechanical complication.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 50 条
  • [21] Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography
    de Heer, Linda M.
    Budde, Ricardo P. J.
    Mali, Willem P. Th. M.
    de Vos, Alexander M.
    van Herwerden, Lex A.
    Kluin, Jolanda
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08): : 1195 - 1204
  • [22] ECG-gated computed tomography to assess pulmonary capillary wedge pressure in pulmonary hypertension
    Nancy Sauvage
    Emilie Reymond
    Adrien Jankowski
    Marion Prieur
    Christophe Pison
    Hélène Bouvaist
    Gilbert R. Ferretti
    European Radiology, 2013, 23 : 2658 - 2665
  • [23] Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography
    Linda M. de Heer
    Ricardo P. J. Budde
    Willem P. Th. M. Mali
    Alexander M. de Vos
    Lex A. van Herwerden
    Jolanda Kluin
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1195 - 1204
  • [24] Pacing and Implantable Cardioverter Defibrillator Lead Perforation As Assessed by Multiplanar Reformatted ECG-Gated Cardiac Computed Tomography and Clinical Correlates
    Pang, Benjamin J.
    Lui, Elaine H.
    Joshi, Subodh B.
    Tacey, Mark A.
    Alison, Jeff
    Seneviratne, Sujith K.
    Cameron, James D.
    Mond, Harry G.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (05): : 537 - 545
  • [25] Multi-Modal Imaging Evaluation of the Aortic Root: ECG-gated and Non-ECG-Gated Computed Tomography versus Echocardiography
    Balesh, Elie
    Bhatt, Paras
    Choi, Perry
    Mojibian, Hamid R.
    CIRCULATION, 2012, 126 (21)
  • [26] IMPROVED ECG-GATED CARDIAC COMPUTERIZED-TOMOGRAPHY
    GARDEN, KL
    BATES, RHT
    NEW ZEALAND MEDICAL JOURNAL, 1983, 96 (729) : 257 - 257
  • [27] ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis
    Erika Fagman
    Sossio Perrotta
    Odd Bech-Hanssen
    Agneta Flinck
    Carl Lamm
    Lars Olaison
    Gunnar Svensson
    European Radiology, 2012, 22 : 2407 - 2414
  • [28] Synthetic ECG-Gated Cardiac Computed Tomography for In Vivo Imaging of the Temporary Total Artificial Heart
    Winkler, Michael A.
    von Herrmann, Paul F.
    Brooks, Michael A.
    Hoopes, Charles W.
    Attili, Anil
    Sorrell, Vincent L.
    CIRCULATION, 2013, 127 (01) : E4 - E5
  • [29] AUTOMATED AGATSTON SCORE COMPUTATION IN A LARGE DATASET OF NON ECG-GATED CHEST COMPUTED TOMOGRAPHY
    Gonzalez, German
    Washko, George R.
    Estepar, Raul San Jose
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 53 - 57
  • [30] Unusual cause of myocardial ischemia noninvasively assessed with ECG-gated computed tomography coronary angiography
    Pugliese, F
    Meijboom, WB
    Cademartiri, F
    Krestin, GP
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (05) : 840 - 840