Preprocedural ECG-Gated Computed Tomography for Prevention of Complications during Lead Extraction

被引:29
|
作者
Lewis, Robert K. [1 ]
Pokorney, Sean D. [1 ]
Greenfield, Ruth Ann [1 ]
Hranitzky, Patrick M. [2 ]
Hegland, Donald D. [1 ]
Schroder, Jacob N. [3 ]
Lin, Shu S. [3 ]
Milano, Carmelo [3 ]
Daubert, James P. [1 ]
Smith, Peter K. [3 ]
Hurwitz, Lynne M. [4 ]
Piccini, Jonathan P. [1 ]
机构
[1] Duke Univ, Med Ctr, Duke Heart Ctr, Cardiac Electrophysiol Sect, Durham, NC 27710 USA
[2] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[3] Duke Univ, Med Ctr, Duke Heart Ctr, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
来源
关键词
cardiac electronic implantable device; lead extraction; computed tomography; ICD; pacemaker; UNITED-STATES; LASER SHEATH; EXPERIENCE;
D O I
10.1111/pace.12485
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPreprocedural multidetector computed tomography (MDCT) may identify patients at risk for mechanical complications during lead extraction. MethodsTo describe the use and feasibility of computed tomography scanning for preprocedural planning of lead extraction, we conducted a retrospective study of high-risk patients, who underwent electrocardiogram (ECG)-gated MDCT before planned lead extraction between January 1, 2012, and March 30, 2013. ResultsAmong 30 patients the mean age was 63 15 years, 60% were male, and 20% had prior sternotomy. Most devices were left sided (93%) and 24 had implantable defibrillators (80%). Indications for extraction included lead malfunction (n = 15; 50%), class I lead advisories (n = 11; 37%), and infection (n = 10; 33%). Overall, there were 65 leads extracted (mean 2.1 leads per patient). One extraction procedure was deferred due to MDCT evidence of significant myocardial perforation with the lead tip > 1 cm beyond the epicardium (n = 1, 3%). MDCT suggestion of lead adherence to central venous structures (n = 13, 43%) was associated with significantly longer laser times (88 +/- 71 seconds vs 30 +/- 37 seconds, P = 0.02) and larger sheath size (14.9 +/- 1.3 vs 13.5 +/- 1.2 French, P = 0.02). MDCT evidence of central venous occlusion or stenosis was not associated with increased laser times. Excluding the patient with MDCT evidence of significant perforation, clinical success was achieved in all patients (n = 29/29). ConclusionsECG-gated MDCT scanning before lead extraction may facilitate the identification of significant perforation and patients at high risk for mechanical complication.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 50 条
  • [1] Comparison of a High-Pitch Non-ECG-Gated and a Prospective ECG-Gated Protocol for Preprocedural Computed Tomography Imaging Before TAVI/TAVR
    Shnayien, Seyd
    Beetz, Nick Lasse
    Bressem, Keno Kyrill
    Hamm, Bernd
    Niehues, Stefan Markus
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (02): : 139 - 147
  • [2] Complications of pulmonary vein isolation by catheter ablation evaluated by ECG-gated multislice computed tomography
    Nobusada Funabashi
    Masayori Yonezawa
    Yoshito Iesaka
    Hideo Umekita
    Noriyuki Yanagawa
    Yasunori Matsumoto
    Katsuya Yoshida
    Issei Komuro
    Heart and Vessels, 2003, 18 : 220 - 223
  • [3] Complications of pulmonary vein isolation by catheter ablation evaluated by ECG-gated multislice computed tomography
    Funabashi, N
    Yonezawa, M
    Iesaka, Y
    Umekita, H
    Yanagawa, N
    Matsumoto, Y
    Yoshida, K
    Komuro, I
    HEART AND VESSELS, 2003, 18 (04) : 220 - 223
  • [4] COMPUTED-TOMOGRAPHY OF THE HEART - ECG-GATED AND CONTINUOUS SCANS
    LACKNER, K
    THURN, P
    RADIOLOGY, 1981, 140 (02) : 413 - 420
  • [5] A PHANTOM FOR TESTING ECG-GATED COMPUTED-TOMOGRAPHY OF THE HEART
    GODWIN, JD
    JOHNSON, GA
    FRAM, EK
    INVESTIGATIVE RADIOLOGY, 1984, 19 (04) : 279 - 283
  • [6] Dynamic Changes in the Aorta During the Cardiac Cycle Analyzed by ECG-Gated Computed Tomography
    Zhu, Wenying
    Wang, Yingliang
    Chen, Yang
    Liu, Jiacheng
    Zhou, Chen
    Shi, Qin
    Huang, Songjiang
    Yang, Chongtu
    Li, Tongqiang
    Xiong, Bin
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [7] An unexpected cause of angina detected by ECG-gated cardiac computed tomography
    Ilias, M
    Mahr, C
    Salanitri, J
    Edelman, R
    Hamilton, A
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02): : 287 - 293
  • [8] ECG-GATED EMISSION COMPUTED-TOMOGRAPHY OF THE CARDIAC BLOOD POOL
    MOORE, ML
    MURPHY, PH
    BURDINE, JA
    RADIOLOGY, 1980, 134 (01) : 233 - 235
  • [9] ECG-gated multidetector computed tomography for the assessment of the postoperative ascending aorta
    Runza, G.
    Fattouch, K.
    Cademartiri, F.
    La Fata, A.
    Damiani, L.
    La Grutta, L.
    Tedeschi, C.
    Basile, A.
    Mollet, N. R.
    Bartolotta, T. V.
    Pisani, G.
    Ruvolo, G.
    Midiri, M.
    Lagalla, R.
    RADIOLOGIA MEDICA, 2009, 114 (05): : 705 - 717
  • [10] ECG-gated multislice computed tomography to assess right ventricular function
    Simon, Marc A.
    Deible, Christopher
    Rajagopalan, Navin
    Madan, Shobhit
    Goitein, Orly
    Lopez-Candales, Angel
    Mathier, Michael
    Lacomis, Joan
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S19 - S20