Anterior deltoid muscle tension quantified with shear wave ultrasound elastography correlates with pain level after reverse shoulder arthroplasty

被引:4
|
作者
Schmalzl, Jonas [1 ,6 ]
Fenwick, Annabel [1 ,2 ]
Reichel, Thomas [3 ]
Schmitz, Benedikt [1 ]
Jordan, Martin [1 ]
Meffert, Rainer [1 ]
Plumhoff, Piet [4 ]
Boehm, Dirk [5 ]
Gilbert, Fabian [1 ]
机构
[1] Univ Hosp Wuerzburg, Dept Trauma Hand Plast & Reconstruct Surg, Oberduerrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Augsburg, Dept Trauma Orthoped Hand & Plast Surg, Stenglinstr 2, D-86156 Augsburg, Germany
[3] Univ Wurzburg, Orthoped Surg, Konig Ludwig Haus,Brettreichstr 11, D-97074 Wurzburg, Germany
[4] Hoechberg Orthopaeden, Hauptstr 78, D-97204 Hoechberg, Germany
[5] Ortho Mainfranken Wuerzburg, Bismarckstr 16, D-97080 Wurzburg, Germany
[6] Univ Hosp Wuerzburg, Dept Traumatol Hand Plast & Reconstruct Surg, Josef Schneider Str 2, D-97080 Wurzburg, Germany
关键词
Shear wave elastography; Strain elastography; Shoulder; Deltoid muscle; Reverse shoulder arthroplasty; pain; QUANTITATIVE ASSESSMENT; ELASTICITY;
D O I
10.1007/s00590-021-02987-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionReverse shoulder arthroplasty (RSA) leads to medialization and distalization of the centre of rotation of the shoulder joint resulting in lengthening of the deltoid muscle. Shear wave ultrasound elastography (SWE) is a reliable method for quantifying tissue stiffness. The purpose of this study was to analyse if deltoid muscle tension after RSA correlates with the patients' pain level. We hypothesized that higher deltoid muscle tension would be associated with increased pain. Material and methodsEighteen patients treated with RSA were included. Constant score (CS) and pain level on the visual analogue scale (VAS) were analysed and SWE was performed on both shoulders. All three regions of the deltoid muscle were examined in resting position and under standardized isometric loading. ResultsAverage patient age was 76 (range 64-84) years and average follow-up was 15 months (range 4-48). The average CS was 66 points (range 35-89) and the average pain level on the VAS was 1.8 (range 0.5-4.7). SWE revealed statistically significant higher muscle tension in the anterior and middle deltoid muscle region in patients after RSA compared to the contralateral non-operated side. There was a statistically significant correlation between pain level and anterior deltoid muscle tension. ConclusionSWE revealed increased tension in the anterior and middle portion of the deltoid muscle after RSA in a clinical setting. Increased tension of the anterior deltoid muscle portion significantly correlated with an increased pain level. SWE is a powerful, cost-effective, quick, dynamic, non-invasive, and radiation-free imaging technique to evaluate tissue elasticity in the shoulder with a wide range of applications. Level of evidenceDiagnostic study, Level III.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 34 条
  • [21] Preoperative deltoid assessment by contrast-enhanced ultrasound (CEUS) as predictor for shoulder function after reverse shoulder arthroplasty: a prospective pilot study
    Christian Fischer
    Sophie Flammer
    Hans-Ulrich Kauczor
    Felix Zeifang
    Gerhard Schmidmaier
    Pierre Kunz
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1001 - 1012
  • [22] Preoperative deltoid assessment by contrast-enhanced ultrasound (CEUS) as predictor for shoulder function after reverse shoulder arthroplasty: a prospective pilot study
    Fischer, Christian
    Flammer, Sophie
    Kauczor, Hans-Ulrich
    Zeifang, Felix
    Schmidmaier, Gerhard
    Kunz, Pierre
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (08) : 1001 - 1012
  • [23] Which patient level factors predict persistent pain after reverse total shoulder arthroplasty?
    Brune, Daniela
    George, Steven Z.
    Edwards, Robert R.
    Moroder, Philipp
    Scheibel, Markus
    Lazaridou, Asimina
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [24] Ultrasound of the Biceps Muscle in Idiopathic Parkinson's Disease with Deep Brain Stimulation: Rigidity Can Be Quantified by Shear Wave Elastography
    Oppold, Julia
    Breu, Maria-Sophie
    Gharabaghi, Alireza
    Grimm, Alexander
    Del Grosso, Nicholas A. A.
    Hormozi, Mohammad
    Kleiser, Benedict
    Klocke, Philipp
    Kronlage, Cornelius
    Weiss, Daniel
    Marquetand, Justus
    DIAGNOSTICS, 2023, 13 (02)
  • [25] Effects of neuromuscular electrical muscle stimulation on the deltoid for shoulder function restoration after reverse total shoulder arthroplasty in the early recovery period: a prospective randomized study
    Jae-Hoo Lee
    Yong-Min Chun
    Doo-Sup Kim
    Doo-Hyung Lee
    Sang-Jin Shin
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3037 - 3046
  • [26] Effects of neuromuscular electrical muscle stimulation on the deltoid for shoulder function restoration after reverse total shoulder arthroplasty in the early recovery period: a prospective randomized study
    Lee, Jae-Hoo
    Chun, Yong-Min
    Kim, Doo-Sup
    Lee, Doo-Hyung
    Shin, Sang-Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3037 - 3046
  • [27] Muscle hardness of the triceps brachii before and after a resistance exercise session: a shear wave ultrasound elastography study
    Akagi, Ryota
    Tanaka, Jun
    Shikiba, Tomofumi
    Takahashi, Hideyuki
    ACTA RADIOLOGICA, 2015, 56 (12) : 1487 - 1493
  • [28] Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration
    Gilbert, Fabian
    Klein, Detlef
    Weng, Andreas Max
    Koestler, Herbert
    Schmitz, Benedikt
    Schmalzl, Jonas
    Boehm, Dirk
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [29] Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration
    Fabian Gilbert
    Detlef Klein
    Andreas Max Weng
    Herbert Köstler
    Benedikt Schmitz
    Jonas Schmalzl
    Dirk Böhm
    BMC Musculoskeletal Disorders, 18
  • [30] Functional outcome and CEUS-assessed deltoid muscle vitality after fracture-specific versus standard prosthetic design in reverse shoulder arthroplasty for trauma
    Doll, Julian
    Neide, Arndt
    Mick, Paul
    Brunnemer, Ulf
    Schmidmaier, Gerhard
    Fischer, Christian
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (03) : 489 - 499