Fiber-optic pH sensor based on poly(o-methoxyaniline)

被引:0
|
作者
Sotomayor, MDT [1 ]
DePaoli, MA [1 ]
deOliveira, WA [1 ]
机构
[1] UNIV ESTADUAL CAMPINAS,INST QUIM,BR-13081970 CAMPINAS,SP,BRAZIL
关键词
pH determination; poly(o-methoxyaniline); fiber-optic chemical sensors; optode;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the development of optical sensors for the measurement of pH. They work by measuring the diffuse reflectance of a conductive polymer, in the visible range of the spectrum. The pH sensitive material was poly(o-methoxyaniline) doped by p-toluene sulfonic acid (PoAnis/TSA), which was immobilized either on or within a polymeric structure. Two optodes were constructed. The first was assembled using a bifurcated bundle of borosilicate optical fibers. The sensing phase was a polymeric composite made of PoAnis/TSA and cellulose acetate, and was fixed at the common end of the bifurcate bundle. This optode allowed measurements in the pH range from 4.9 to 10.5 with a precision of +/-0.01 pH. The response time for 90% change was 5.0 min for a full pH variation from acid to basic, and 22 min for the reversal change. The sensor response depends on the ionic strength of the solution and on the supporting electrolyte used to adjust the ionic strength. The second optode was built using two cables of optical fibers, each one having a single plastic fiber with 1.0 mm diameter. The two cables were fixed in a Perspex block, together with the pH sensitive layer. The sensing phase of this optode consisted of a film of PoAnis/TSA adsorbed on polyethylene. This optode yielded measurements in a working range from pH 2.0-10.0 and with relatively faster response time for 90% change for a variation from basic to acid (5.0 min). It was verified that pH sensors based on poly(o-methoxyaniline) offer a wide dynamic range but suffer from long response times and interferences from both cations and anions. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 50 条
  • [31] Extrinsic Fiber-Optic Sensor for Detection of Saliva pH
    Vlastimil Matějec
    Ivo Barton
    Marie Pospisilova
    Lenka Traplova
    Chemistry Africa, 2019, 2 : 301 - 307
  • [32] Extrinsic Fiber-Optic Sensor for Detection of Saliva pH
    Matejec, Vlastimil
    Barton, Ivo
    Pospisilova, Marie
    Traplova, Lenka
    CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2019, 2 (02): : 301 - 307
  • [33] Physicochemical and catalytic properties of palladium supported on poly(o-methoxyaniline)
    Drelinkiewicz, A
    Hasik, M
    Sobczak, JW
    Sobczak, E
    Bemasik, A
    Bielanska, E
    MATERIALS RESEARCH BULLETIN, 2005, 40 (05) : 869 - 889
  • [34] The Effects of Dopant Acids on Structure and Properties of Poly(o-methoxyaniline)
    Wang, Xiao
    Ray, Sudip
    Gizdavic-Nikolaidis, Marija
    Easteal, Allan J.
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2012, 50 (02) : 353 - 361
  • [35] Fiber-optic sensor for continuous monitoring of fermentation pH
    Agayn, Venetka I.
    Walt, David R.
    Bio/Technology, 1993, 11 (06):
  • [36] Corrosion inhibition of polyaniline and poly (o-methoxyaniline) on stainless steels
    Kilmartin, PA
    Trier, L
    Wright, GA
    SYNTHETIC METALS, 2002, 131 (1-3) : 99 - 109
  • [37] POLY(O-METHOXYANILINE) MODIFIED ELECTRODE FOR DETECTION OF LITHIUM IONS
    Lindino, Cleber Antonio
    Casagrande, Marcella
    Peiter, Andreia
    Ribeiro, Caroline
    QUIMICA NOVA, 2012, 35 (03): : 449 - 453
  • [38] Structure and properties of poly(o-methoxyaniline)-clay nanocomposite materials
    Yeh, JM
    Chin, CP
    JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 88 (04) : 1072 - 1080
  • [39] Poly(O-methoxyaniline) thin films:: Cyclic voltammetry study
    Patil, S
    More, MA
    Patil, PP
    JOURNAL OF APPLIED POLYMER SCIENCE, 1999, 74 (13) : 3009 - 3015
  • [40] Adsorption of poly(o-methoxyaniline) in layer-by-layer films
    Raposo, M
    Oliveira, ON
    LANGMUIR, 2002, 18 (18) : 6866 - 6874