Investigation of a high-resolution detector for wholebody PET imaging

被引:0
|
作者
Surti, Suleman [1 ]
Kuhn, Austin [1 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Increased focus towards improved detector spatial resolution in PET (for whole-body as well as small animal imaging) has led to the use of smaller crystals in some form of light sharing detector design. We have performed simulations for a generic whole-body scanner with varying crystals sizes in order to better understand the limitations in achieving good uniform spatial resolution using discrete crystal based detectors in a whole-body scanner. These results show that using small 2-mm crystals leads to a noticeable improvement in the reconstructed spatial resolution of whole-body scanners due to better sampling in the sinogram. Over the years we have investigated using large continuous detectors with Anger positioning, cutting slots in continuous detectors to produce semi-continuous detectors, and more recently pixelated Anger-logic detectors. Our aim is to develop a new detector concept that incorporates high detector sampling with very good intrinsic spatial resolution to produce high resolution reconstructed images. In this work we investigate three different techniques for achieving our goals: Using regions-of-interest (ROI) which are half the crystal size in the crystal identification map. Dual layers of 4x4x.15-mm3 offset crystals. Large continuous Crystals with 3D positioning of interaction (313 crystals) using maximum likelihood positioning algorithm. Our results show a reasonable improvement in spatial resolution (1-mm at center) using smaller ROI's and a similar improvement in off-center positions using the offset crystals. A more noticeable improvement is observed with the 3D crystal detector where the resolution seems to be intrinsically limited by the physics of positron annihilation and amount of Compton scatter in the crystal.
引用
收藏
页码:1601 / 1605
页数:5
相关论文
共 50 条
  • [21] High-resolution ultrasonic imaging using an etalon detector array
    Huang, Sheng-Wen
    Hou, Yang
    Ashkenazi, Shai
    O'Donnell, Matthew
    APPLIED PHYSICS LETTERS, 2008, 93 (11)
  • [22] Detector Characterization of a High-Resolution Ring for PET Imaging of Mice Heads With Sub-200-ps TOF
    Valladares, Celia
    Barrio, John
    Cucarella, Neus
    Freire, Marta
    Vidal, Luis F.
    Benlloch, Jose M.
    Gonzalez, Antonio J.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (08) : 876 - 885
  • [23] Design study of a detector insert for high resolution clinical PET imaging
    Tai, YC
    Laforest, R
    Ruangma, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1714 - 1717
  • [24] HIGH-RESOLUTION TOPOGRAPHY DETECTOR
    CHIKAWA, J
    SATO, F
    FUJIMOTO, I
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C403 - C403
  • [25] A HIGH-RESOLUTION MUON DETECTOR
    ADEVA, B
    AGUILARBENITEZ, M
    ALCARAZ, J
    ALOISIO, A
    ALVIGGI, MG
    ANTREASYAN, D
    BECKER, U
    BERDUGO, J
    BOBBINK, GJ
    BRAMBILLA, E
    BRANSON, JD
    BUJAK, A
    BURGOS, C
    BURGER, JD
    CARLINO, G
    CERRADA, M
    CHANG, YH
    CHIEFARI, G
    COLINO, N
    DRAGO, E
    DUINKER, P
    DURAN, I
    ERNE, F
    FABBRETTI, R
    FABRE, M
    GAU, SS
    GETTNER, M
    GONZALEZ, E
    VANDERGRAAF, H
    GUESEWELL, D
    GUTAY, LG
    HARTJES, FG
    HU, G
    INNOCENTE, V
    JIN, BN
    KONIG, AC
    KUMMAR, KS
    LANZANO, S
    LEGOFF, JM
    LEIJTENS, X
    LI, L
    MANA, C
    MAO, YF
    MARTINEZLASO, L
    MASSARO, GGG
    MCBRIDE, P
    MCMAHON, T
    MEROLA, L
    ONVLEE, H
    PATERNOSTER, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (1-2): : 109 - 124
  • [26] A new PET detector concept for compact preclinical high-resolution hybrid MR-PET
    Berneking, Arne
    Gola, Alberto
    Ferri, Alessandro
    Finster, Felix
    Rucatti, Daniele
    Paternoster, Giovanni
    Shah, N. Jon
    Piemonte, Claudio
    Lerche, Christoph
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 44 - 52
  • [27] A NEW DUAL CRYSTAL DEPTH SENSITIVE DETECTOR FOR HIGH-RESOLUTION PET CAMERAS
    LECOMTE, R
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 974 - 974
  • [28] OBJECT AND DETECTOR SCATTER FUNCTION DEPENDENCE ON ENERGY AND POSITION IN HIGH-RESOLUTION PET
    BENTOURKIA, M
    MSAKI, P
    CADORETTE, J
    LECOMTE, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1162 - 1167
  • [29] Development of a LGSO detector using a tapered fiber for a high-resolution animal PET
    Yamamoto, S
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1611 - 1614
  • [30] High-resolution image reconstruction for PET using estimated detector response functions
    Tohme, Michel S.
    Qi, Jinyi