Improving the Signal-to-Noise Ratio of Underground Nuclear Magnetic, Resonance Data Based on the Nearby Reference Noise Cancellation Method

被引:5
|
作者
Zhang, Jian [2 ]
Du, Guanfeng [2 ]
Lin, Jun [2 ]
Yi, Xiaofeng [2 ]
Jiang, Chuandong [1 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130061, Jilin, Peoples R China
[2] Jilin Univ, Key Lab Geophys Explorat Equipment, Minist Educ China, Changchun 130061, Jilin, Peoples R China
基金
美国国家科学基金会;
关键词
Nuclear magnetic resonance; signal-to-noise ratio; reference noise cancellation; nearby reference coil; PRINCIPLES; HARMONICS; REMOVAL; TIME;
D O I
10.1109/ACCESS.2019.2920845
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Surface and underground nuclear magnetic resonance (UNMR) method has the advantage of direct and quantitative detection of groundwater and has been widely used in water resource survey and advance detection of water sources causing disaster in underground space. However, the UNMR signal is extremely weak in tunnels or mines. The signal-to-noise ratio (SNR) of received data at one single record is even less than -20 dB because of the strong environmental noise. A nearby reference noise cancellation (NRNC) method is proposed in this study to improve SNR. The method calculates the transfer function between the reference coil and the detection coil by using the second half of the received data to determine the noise estimation in the first half of the detection coil. The non-linear fitting method is used to estimate and remove the UNMR signal in the noise estimation and avoid the loss of the UNMR signal in the detection coil. We compare the nearby reference coil layouts of coaxial, non-separation tri-axial, and separation tri-axial types, as well as the NRNC results of the number and distance of different reference coils, through a large number of experiments. The non-separation tri-axial reference coil is optimal. The experimental results show that the SNR can be increased significantly by 18.1 dB, and the uncertainty in UNMR signal parameter estimation is evidently decreased. We prove that the NRNC algorithm is superior to the existing remote reference noise cancellation and power frequency modeling algorithms, and discuss that the improvement in SNR will be beneficial to improve the accuracy of inversion results.
引用
收藏
页码:75265 / 75275
页数:11
相关论文
共 50 条
  • [21] Improving signal-to-noise ratio in ultrasonic testing
    Krivosheev, I. A.
    Ignat'eva, M. I.
    Shamurina, A. I.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2016, 52 (06) : 310 - 314
  • [22] INFRASONIC ARRAY FOR IMPROVING SIGNAL-TO-NOISE RATIO
    谢金来
    王俊生
    Chinese Journal of Acoustics, 1986, (03) : 271 - 279
  • [23] EXPRESSION FOR SIGNAL-TO-NOISE RATIO IN NUCLEAR MAGNETIC RESONANCE DETECTION USING PHASE SENSITIVE DETECTOR
    MURTHY, SV
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1962, B 21 (07): : 333 - &
  • [24] SIGNAL-TO-NOISE RATIO IN ACCUMULATION OF FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE SPECTRA
    KIMBER, BJ
    ROTH, K
    FEENEY, J
    ANALYTICAL CHEMISTRY, 1981, 53 (07) : 1026 - 1030
  • [25] Boosting magnetic resonance imaging signal-to-noise ratio using magnetic metamaterials
    Duan, Guangwu
    Zhao, Xiaoguang
    Anderson, Stephan William
    Zhang, Xin
    COMMUNICATIONS PHYSICS, 2019, 2 (1)
  • [26] Boosting magnetic resonance imaging signal-to-noise ratio using magnetic metamaterials
    Guangwu Duan
    Xiaoguang Zhao
    Stephan William Anderson
    Xin Zhang
    Communications Physics, 2
  • [27] Denoising magnetic resonance spectroscopy (MRS) data using stacked autoencoder for improving signal-to-noise ratio and speed of MRS
    Wang, Jing
    Ji, Bing
    Lei, Yang
    Liu, Tian
    Mao, Hui
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2023, 50 (12) : 7955 - 7966
  • [28] Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images
    K. S. Sim
    M. A. Lai
    C. P. Tso
    C. C. Teo
    Journal of Medical Systems, 2011, 35 : 39 - 48
  • [29] AN UNBIASED SIGNAL-TO-NOISE RATIO MEASURE FOR MAGNETIC-RESONANCE IMAGES
    MCGIBNEY, G
    SMITH, MR
    MEDICAL PHYSICS, 1993, 20 (04) : 1077 - 1078
  • [30] Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images
    Sim, K. S.
    Lai, M. A.
    Tso, C. P.
    Teo, C. C.