A Partial-Volume Correction for Quantitative Spectral X-Ray Radiography

被引:2
|
作者
Gillis, Wesley Collins [1 ]
Gilbert, Andrew James [2 ]
Pazdernik, Karl [2 ]
Erickson, Anna [1 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Nucl & Radiol Engn & Med Phys Programs, Atlanta, GA 30332 USA
[2] Pacific Northwest Natl Lab, Richland, WA 99352 USA
关键词
Detectors; Radiography; Attenuation; X-ray imaging; Prediction algorithms; Uranium; Material discrimination; nonlinear least-squares; partial-volume effect; spectral X-ray radiography; PIXEL READOUT CHIP; DETECTOR ARRAYS; WORKING;
D O I
10.1109/TNS.2020.3028009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The technique of spectral radiography has been shown to accurately discriminate a material's elemental composition by using known X-ray physics. In previous work, we presented a system for determining the total compositional mass of UO2 powder. This is achieved with a state-of-the-art pixelated spectrometer and a high-fidelity physical model. Similar to other radiographs, the system suffers from partial-volume attenuation where the sample projection onto a pixel is only a fraction of the pixel area, leaving the rest unattenuated. This study updates the physical model to account for fractional area which challenges the existing algorithm. We present how this update is made and explore approaches to stabilize the algorithm through parameter scaling, constrained optimization, and hyperparameter selection. We applied the updated algorithm to calculate the total uranium and oxygen mass of UO2 powder simulations. The average relative error on total uranium mass was reduced from 1.4% to 0.068% and on total oxygen mass from 122.2% to 4.2%.
引用
收藏
页码:2321 / 2328
页数:8
相关论文
共 50 条
  • [21] Partial-Volume Effect Correction Improves Quantitative Analysis of 18F-Florbetaben β-Amyloid PET Scans
    Rullmann, Michael
    Dukart, Juergen
    Hoffmann, Karl-Titus
    Luthardt, Julia
    Tiepolt, Solveig
    Patt, Marianne
    Gertz, Hermann-Josef
    Schroeter, Matthias L.
    Seiby, John
    Schulz-Schaeffer, Walter J.
    Sabri, Osama
    Barthel, Henryk
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 198 - 203
  • [22] Evaluation of partial coherence correction in X-ray ptychography
    Burdet, Nicolas
    Shi, Xiaowen
    Parks, Daniel
    Clark, Jesse N.
    Huang, Xiaojing
    Kevan, Stephen D.
    Robinson, Ian K.
    OPTICS EXPRESS, 2015, 23 (05): : 5452 - 5467
  • [23] CORRECTION OF PARTIAL-VOLUME EFFECTS IN PHASE-CONTRAST FLOW MEASUREMENTS
    TANG, C
    BLATTER, DD
    PARKER, DL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 175 - 180
  • [24] QUANTITATIVE X-RAY SPECTRAL MICROANALYSIS OF NONCONDUCTING SUBSTANCES
    KUPRIYANOVA, TA
    SYSOEVA, LN
    INDUSTRIAL LABORATORY, 1980, 46 (02): : 132 - 136
  • [25] QUANTITATIVE METHODS OF LOCAL X-RAY SPECTRAL ANALYSIS
    RYDNIK, VI
    BOROVSKI.IB
    INDUSTRIAL LABORATORY, 1967, 33 (08): : 1126 - &
  • [26] DEVELOPMENT OF THEORY OF QUANTITATIVE X-RAY SPECTRAL MICROANALYSIS
    V.P.Afonin
    电子显微学报, 1991, (02) : 188 - 189
  • [27] QUANTITATIVE X-RAY SPECTRAL MICROANALYSIS (REPORT 2)
    ILIN, NP
    LOSEVA, LE
    INDUSTRIAL LABORATORY, 1967, 33 (08): : 1122 - &
  • [28] X-RAY RADIOGRAPHY OF COAL
    VINOPAL, R
    JOURNAL OF SEDIMENTARY PETROLOGY, 1979, 49 (02): : 483 - 486
  • [29] Quantitative x-ray radiography using grating interferometry: a feasibility study
    Wang, Zhentian
    Stampanoni, Marco
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6815 - 6826
  • [30] Preliminary Study of Quantitative X-ray Spectral Imaging with Spectral Deconvolution
    Wang, Sen
    Zhang, Li
    Xu, Xiaofei
    Wu, Dufan
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,