Testing of the analytical anisotropic algorithm for photon dose calculation

被引:212
|
作者
Van Esch, Ann
Tillikainen, Laura
Pyykkonen, Jukka
Tenhunen, Mikko
Helminen, Hannu
Siljamaki, Sami
Alakuijala, Jyrki
Paiusco, Marta
Iori, Mauro
Huyskens, Dominique P.
机构
[1] Varian Med Syst, Helsinki, Finland
[2] Helsinki Univ Hosp, Helsinki, Finland
[3] Varian Med Syst, Helsinki, Finland
[4] San Maria Nuova Hosp, Reggio Emilia, Italy
关键词
D O I
10.1118/1.2358333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the super-position of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of MonteCarlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimization algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below d(max). The electron contamination model was found to be suboptimal to model the dose around d(max,) especially for physical wedges at smaller source to phantom distances. For the asymmetric field verification, absolute dose difference of up to 4% were observed for the most extreme asymmetries. Compared to the SPB, the penumbra modeling is considerably improved (1%, 1 mm). At the interface between solid water and cork, profiles show a better agreement with AAA. Depth dose curves in the cork are substantially better with AAA than with SPB. Improvements are more pronounced for 18 MV than for 6,MV. Point dose measurements in the thoracic phantom are mostly within 5%. In general, we can conclude that, compared to SPB, AAA improves the accuracy of dose calculations. Particular progress was made with respect to the penumbra and low dose regions. In heterogeneous materials, improvements are substantial and more pronounced for high (18 MV) than for low (6 MV) energies. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4130 / 4148
页数:19
相关论文
共 50 条
  • [11] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414
  • [12] On the clinical and dosimetric accuracy of Anisotropic Analytical Algorithm photon dose calculation in the case of lung inhomogeneities for IMRT treatment
    Khodri, M.
    Plattard, D.
    Martin, H.
    Tete, I.
    Remmi, N.
    Schmitt, T.
    Delaroche, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S716 - S716
  • [13] On the clinical and dosimetric accuracy of anisotropic analytical algorithm photon dose calculation in the case of lung inhomogeneities for IMRT treatment
    Khodri, M.
    Plattard, D.
    Martin, H.
    Tete, I.
    Remini, N.
    Delaroche, G.
    Schmitt, T.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S194 - S194
  • [14] Evaluation of an Analytical Anisotropic Dose Calculation Algorithm in a Heterogeneous Medium Using In Vivo Dosimetry for High-Energy Photon Beams
    Berkani, Yasmina
    Khelifi, Rachid
    Iranian Journal of Medical Physics, 2022, 19 (01): : 22 - 30
  • [15] On the Clinical and Dosimetric Accuracy of Recently Released Advanced Dose Calculation Algorithm and Analytical Anisotropic Algorithm (AAA) Photon Dose Calculation Algorithms for SBRT Lung Treatment With Volumetric Modulated Arc Therapy (VMAT)
    Khodri, M.
    Largeron, G.
    Nguyen, D.
    Lorchel, F.
    Passerat, V.
    Pouchard, I.
    Barbet, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S825 - S825
  • [16] Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA)
    Rana, S.
    Rogers, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3827 - 3827
  • [17] Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm
    Newhauser, Wayne
    Fontenot, Jonas
    Zheng, Yuanshui
    Polf, Jerimy
    Titt, Uwe
    Koch, Nicholas
    Zhang, Xiaodong
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4569 - 4584
  • [18] Testing the Limitations of a Photon Dose Algorithm in Commissioning
    Xue, J.
    Choi, M.
    Park, J.
    LaCouture, T.
    Ibbott, G.
    MEDICAL PHYSICS, 2015, 42 (06) : 3503 - 3503
  • [19] ANISOTROPIC ANALYTICAL ALGORITHM DOSIMETRIC TESTS FOR 15 MY PHOTON BEAM
    Oliveira e Silva, L. F.
    Batista, D.
    Santos Fortes, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S481 - S481
  • [20] Validation of ClearCalc Photon Secondary Check Dose Calculation Algorithm
    Wong, J.
    Lei, Y.
    Wisnoskie, S.
    Granatowicz, A.
    Wang, S.
    Besemer, A.
    Hyun, M.
    Zhou, S.
    Enke, C.
    Fan, Q.
    MEDICAL PHYSICS, 2021, 48 (06)