Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator

被引:3
|
作者
Rajasekar, D [1 ]
Datta, NR [1 ]
Das, KJM [1 ]
Ayyagari, S [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Radiotherapy, Lucknow, Uttar Pradesh, India
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 18期
关键词
D O I
10.1088/0031-9155/47/18/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies-6, 9, 12, 15 and 20 MeV-and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5 x 5 to 15 x 15 cm(2) for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation coefficients between the calculated and the measured values. The correlation coefficient was best with the linear-quadratic equation followed by the effective SSD method and the virtual source method. The output correction based on the linear-quadratic equation showed the best estimate of electron beam output at extended SSDs with an accuracy well within +/-1%. The rapid reduction of dose due to the applicator-scattered component at d(max) point with an extended SSD was significant for the 5 x 5 cm(2) applicator and lower energies.
引用
收藏
页码:3301 / 3311
页数:11
相关论文
共 50 条
  • [31] HIGH-CURRENT ELECTRON BEAM IN A LINEAR INDUCTION ACCELERATOR
    VAKHRUSH.YP
    KUZNETSO.VS
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 14 (03): : 374 - &
  • [32] Steering an intense relativistic electron beam in a linear induction accelerator
    Ekdahl, Carl
    Allison, P.
    Coleman, J. E.
    Kaupilla, T.
    McCuistian, B. T.
    Moir, D. C.
    Schulze, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [33] SYSTEM FOR MEASURING ELECTRON BEAM ENERGY SPECTRUM AT A LINEAR ACCELERATOR
    KARAS, VL
    MAKHNENK.LA
    SKUBKO, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (03): : 540 - +
  • [34] DESIGN OF A NONLAMINAR ELECTRON BEAM IN A LINEAR INDUCTION ACCELERATOR.
    Merkulov, L.A.
    Soviet journal of communications technology & electronics, 1986, 3 l (09): : 9 - 15
  • [35] LINEAR ELECTRON-ACCELERATOR WITH 2-COMPONENT BEAM
    GRIZHKO, VM
    GRISHAEV, IA
    FURSOV, GL
    ZHURNAL TEKHNICHESKOI FIZIKI, 1979, 49 (02): : 350 - 351
  • [36] Routine Linear Accelerator Electron Beam QA Using EPIDs
    Wang, Y.
    Norrlinger, B.
    Smale, J.
    Islam, M.
    MEDICAL PHYSICS, 2008, 35 (06) : 2775 - +
  • [37] A Novel Compact and Portable Linear Accelerator Electron Beam System
    Miller, R. Bruce
    Trujillo, Henry
    Johnson, Richard W.
    Andreev, Andrey D.
    Smith, Don
    Lopez, Alberto
    Lockwood, Nathaniel P.
    Enderich, Daniel A.
    Harris, John R.
    Schaub, Samuel C.
    Lambrecht, Michael R.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (04) : 1085 - 1091
  • [38] ELECTRON BEAM SHAPING IN A LINEAR TRAVELING-WAVE ACCELERATOR
    OSTROVSK.EK
    MAKAROV, AF
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1969, 13 (09): : 1244 - &
  • [39] REGULATING AND MEASURING CURRENT OF PULSED BEAM OF LINEAR ELECTRON ACCELERATOR
    KOZLOV, YD
    MATYUKOV, MD
    SEKACHEV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (04): : 898 - &
  • [40] THE CALCULATION OF NONLAMINAR ELECTRON-BEAM IN LINEAR INDUCTION ACCELERATOR
    MERKULOV, LA
    RADIOTEKHNIKA I ELEKTRONIKA, 1986, 31 (04): : 792 - 799