Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator

被引:3
|
作者
Rajasekar, D [1 ]
Datta, NR [1 ]
Das, KJM [1 ]
Ayyagari, S [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Radiotherapy, Lucknow, Uttar Pradesh, India
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 18期
关键词
D O I
10.1088/0031-9155/47/18/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies-6, 9, 12, 15 and 20 MeV-and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5 x 5 to 15 x 15 cm(2) for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation coefficients between the calculated and the measured values. The correlation coefficient was best with the linear-quadratic equation followed by the effective SSD method and the virtual source method. The output correction based on the linear-quadratic equation showed the best estimate of electron beam output at extended SSDs with an accuracy well within +/-1%. The rapid reduction of dose due to the applicator-scattered component at d(max) point with an extended SSD was significant for the 5 x 5 cm(2) applicator and lower energies.
引用
收藏
页码:3301 / 3311
页数:11
相关论文
共 50 条
  • [1] Monte Carlo calculations of electron beam output factors for a medical linear accelerator
    Kapur, A
    Ma, CM
    Mok, EC
    Findley, DO
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12): : 3479 - 3494
  • [2] PARAMETERIZATION OF THE ELECTRON-BEAM OUTPUT FACTORS OF A 25 MEV LINEAR-ACCELERATOR
    MCPARLAND, BJ
    MEDICAL PHYSICS, 1987, 14 (03) : 474 - 474
  • [3] A PARAMETERIZATION OF THE ELECTRON-BEAM OUTPUT FACTORS OF A 25-MEV LINEAR-ACCELERATOR
    MCPARLAND, BJ
    MEDICAL PHYSICS, 1987, 14 (04) : 665 - 669
  • [4] DETERMINATION OF ELECTRON-BEAM OUTPUT FACTORS FOR A 20-MEV LINEAR-ACCELERATOR
    MILLS, MD
    HOGSTROM, KR
    FIELDS, RS
    MEDICAL PHYSICS, 1985, 12 (04) : 473 - 476
  • [5] Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter
    Czarnecki, D.
    von Voigts-Rhetz, P.
    Poppe, B.
    Zink, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3652 - 3652
  • [6] ANALYSIS OF LATERAL INSTABILITY OF A BEAM IN LINEAR ELECTRON-ACCELERATOR
    MONDRUS, IN
    SHENDEROVICH, AM
    ZHURNAL TEKHNICHESKOI FIZIKI, 1990, 60 (08): : 164 - 172
  • [7] A simple empirical algorithm for electron output calculation for small fields and extended SSDs
    Burmeister, J
    Peng, W
    MEDICAL PHYSICS, 2003, 30 (06) : 1519 - 1519
  • [8] IORT Novac7: A new linear accelerator for electron beam therapy
    Fantini, M
    Santoni, F
    Soriani, A
    Creton, G
    Benassi, M
    Begnozzi, L
    INTRAOPERATIVE RADIATION THERAPY IN THE TREATMENT OF CANCER, 1997, 31 : 54 - 59
  • [9] OPTICAL CHARACTERISTICS OF BEAM OF A LINEAR ELECTRON ACCELERATOR
    DEMYANEN.GK
    RYABKA, PM
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1970, 14 (12): : 1622 - &
  • [10] RADIAL BEAM CONFINEMENT IN A LINEAR ELECTRON ACCELERATOR
    DEMYANENKO, GK
    KOLESNIK.LY
    MIROSHNI.II
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1968, 12 (07): : 883 - +