Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length

被引:66
|
作者
Chen, Mei-Ju [1 ,2 ]
Liu, Yin-Tzu [1 ]
Tsai, Chia-Chen [2 ,3 ]
Chen, Yen-Cheng [2 ]
Chou, Ching-Kuang [1 ,2 ]
Lee, Shu-Mei [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Ophthalmol, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[3] Cheng Hsin Gen Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; axial length; central corneal thickness; corneal curvature; refractive error; INTRAOCULAR-PRESSURE; GLAUCOMA; CHINESE; MYOPIA;
D O I
10.1016/S1726-4901(09)70038-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To determine the relationship between central corneal thickness (CCT), refractive error, corneal curvature, anterior chamber depth and axial length in normal Taiwanese Chinese adults. Methods: Five hundred normal Taiwanese Chinese patients aged 40-80 years were recruited for the study. Measurement procedures included CCT, refractive error, corneal curvature, anterior chamber depth and axial length. Exclusion criteria were previous ocular surgery, glaucoma, trauma history, external eye disease, and previous contact lens use. The relationships among parameters were tested using Pearson's correlation and linear regression analysis. Results: The median CCT was 555 +/- 27 mu m for males and 553 +/- 30 mu m for females. Eyes with more myopic refractive error tended to have greater axial length (r= -0.645, p < 0.001). Eyes with axial elongation tended to have flatter cornea (r= -0.502, p < 0.001) and deeper anterior chamber (r= 0.651, p < 0.001). There were no significant correlations between the CCT and refractive error (r=-0.034, p=0.445), corneal curvature (r=0.013, p=0.770), anterior chamber depth (r=0.023, p=0.614) and axial length (r=-0.053, p=0.223). Conclusion: CCT was not associated with refractive error, corneal curvature, anterior chamber depth and axial length. CCT is an independent factor unrelated to other ocular parameters. [J Chin Med Assoc 2009;72(3):133-137]
引用
收藏
页码:133 / 137
页数:5
相关论文
共 50 条
  • [21] Comparison of central corneal thickness, corneal curvature and axial length values in pseudoexfoliation cases with or without cataract
    Okumus, Seydi
    Tatar, M. Gurkan
    Gungor, Kivanc
    Bekir, Necdet
    EUROPEAN JOURNAL OF THERAPEUTICS, 2011, 17 (03): : 137 - 140
  • [22] The comparative study of two recently developed A-scan devices:: determination of central corneal thickness, anterior chamber depth and axial length
    Sohajda, Zoltan
    Papp, Julia
    Berta, Andras
    Modis, Laszlo
    ACTA OPHTHALMOLOGICA, 2008, 86 (01) : 45 - 48
  • [23] Heritability Analysis of Spherical Equivalent, Axial Length, Corneal Curvature, and Anterior Chamber Depth in the Beaver Dam Eye Study
    Klein, Alison P.
    Suktitipat, Bhoom
    Duggal, Priya
    Lee, Kristine E.
    Klein, Ronald
    Bailey-Wilson, Joan E.
    Klein, Barbara E. K.
    ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (05) : 649 - 655
  • [24] Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known Biometer
    Shajari, Mehdi
    Cremonese, Carla
    Petermann, Kerstin
    Singh, Pankaj
    Mueller, Michael
    Kohnen, Thomas
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 178 : 58 - 64
  • [25] AXIAL LENGTH, CORNEAL CURVATURE AND THEIR ASSOCIATION WITH THE REFRACTIVE STATUS OF THE EYE
    Karunakar, B.
    Rajlingam
    Reddy, Lokabi
    Murthy, Srinivas
    Srikanth
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (10): : 422 - 426
  • [26] Relationship between central corneal thickness and refractive error in Caucasian and African American glaucoma patients
    Radcliffe, NM
    Stein, J
    Farris, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [27] The relationship between the sagitta of the anterior corneal surface and refractive error of the eye
    Garner, LF
    Owens, H
    OPTOMETRY AND VISION SCIENCE, 2004, 81 (08) : 636 - 639
  • [28] Central corneal thickness, axial length, anterior chamber and optic disc structure in patients with central and branch retinal vein occlusion
    Vural, Gozde Sahin
    Karahan, Eyyup
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 1077 - 1083
  • [29] Comparison of Central Corneal Thickness and Anterior Chamber Depth measured by Three Different Devices
    Shin, Minchul
    Chung, Se Yoon
    Lee, Hyo Kyung
    Hwang, Ho Sik
    Han, Kyung Eun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [30] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576