Assessment of Intra- and Inter-observer Measurement Variability in a Radiographic Metacarpophalangeal Joint Osteophytosis Scoring System for the Horse

被引:3
|
作者
Lacitignola, Luca [1 ]
Imperante, Annarita [2 ]
Staffieri, Francesco [1 ]
De Siena, Rocco
De Luca, Pasquale
Muci, Arianna
Crovace, Antonio [1 ]
机构
[1] Univ Bari Aldo Moro, Dipartimento Emergenza & Trapianti Organi DETO, Sez Clin Vet & PA, Sp Casamassima Km 3 Valenzano, I-70010 Bari, Italy
[2] Univ Bari Aldo Moro, Trapianti Tessuti & Organi & Terapie Cellulari, Dipartimento Emergenza & Trapianti Organi DETO, I-70010 Bari, Italy
关键词
horse; metacarpophalangeal joint; radiographs; osteoarthritis; osteophytosis;
D O I
10.3390/vetsci7020039
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The study evaluated the intra- and inter-observer measurement variability of an osteophytosis metacarpophalangeal joint scoring system. Ten (n = 10) dorso/palmar, latero/medial, and oblique views of equine metacarpophalangeal joints affected by osteoarthritis were examined. Nine assessment points were graded (scale: 0-3) twice by five veterinary students (inexperienced group, I) and four equine veterinary surgeons (expert group, E). The grades for each of the nine factors were summed to obtain the osteophytosis score. The variability between the two measurements was -2.04 +/- 3.5, 95% CI -3.04 to -1.03 for the I group. For the E group, they were 0 +/- 1.43, 95% CI -0.45 to 0.45. In the evaluation of the same radiographs, the I group had a coefficient of variability (CV) of 37.29%. The correlation was r = 0.90%. The CV between groups was 28.85%. The mean difference between the two observations was -0.03 +/- 0.29 in the E group and 0.22 +/- 0.77 in the I group. The I group showed a greater CV when the score was low (r = -0.78) compared to the E group, where the CV was independent of severity of osteophytosis (r = -0.47). The osteophytosis scoring system is an easily applicable and feasible system to be used by observers with different levels of experience, but inexpert observers may need additional training or may need to be helped by reference images. These data are validated by the low inter- and intra-observer measurement variability results in the E group. Therefore, the scoring system proposed seems to be a repeatable instrument applicable to the radiographic score of the severity of metacarpophalangeal joint osteoarthritis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of Intra- and Inter-observer Measurement Variability of a Radiographic Stifle Osteoarthritis Scoring System in Dogs
    Wessely, Marlis
    Bruehschwein, Andreas
    Schnabl-Feichter, Eva
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (06) : 377 - 384
  • [2] INTRA- AND INTER-OBSERVER VARIATIONS IN ASSESSMENT OF EMPHYSEMA
    THURLBEC.WM
    HOROWITZ, I
    SIEMIATY.J
    DUNNILL, MS
    MAISEL, JC
    PRATT, P
    RYDER, R
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1969, 18 (04): : 646 - &
  • [3] Assessment of inter-observer and intra-observer variability in the measurement of QT dispersion
    Bhullar, HK
    Chia, P
    Ong, K
    Ng, WL
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 297 - 300
  • [4] Intra- and inter-observer variability of functional MR urography (fMRU) assessment in children
    Dmitry Khrichenko
    David Saul
    Melkamu Adeb
    Camilo Jaimes
    Khalil N. Betts
    Stephanie M. Barron
    J. Christopher Edgar
    Sarah M. Lambert
    Pasquale Casale
    Kassa Darge
    Pediatric Radiology, 2016, 46 : 666 - 673
  • [5] Intra- and inter-observer variability of functional MR urography (fMRU) assessment in children
    Khrichenko, Dmitry
    Saul, David
    Adeb, Melkamu
    Jaimes, Camilo
    Betts, Khalil N.
    Barron, Stephanie M.
    Edgar, J. Christopher
    Lambert, Sarah M.
    Casale, Pasquale
    Darge, Kassa
    PEDIATRIC RADIOLOGY, 2016, 46 (05) : 666 - 673
  • [6] MEASUREMENT OF LIVER AND SPLEEN STIFFNESS BY ARFI ELASTOGRAPHY: INTRA- AND INTER-OBSERVER VARIABILITY AND PREDICTORS OF VARIABILITY
    Balakrishnan, M.
    Souza, F.
    Munoz, C.
    Augustin, S.
    Loo, N.
    Deng, Y.
    Ciarleglio, M.
    Garcia-Tsao, G.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S412 - S413
  • [7] Measurement of Liver and Spleen Stiffness by ARFI Elastography: Intra- and Inter-Observer Variability and Predictors of Variability
    Balakrishnan, Maya
    Souza, Fernanda F.
    Munoz, Carolina
    Augustin, Salvador
    Loo, Nicole M.
    Deng, Yanhong
    Garcia-Tsao, Guadalupe
    Ciarleglio, Maria
    GASTROENTEROLOGY, 2014, 146 (05) : S934 - S934
  • [8] Intra- and inter-observer reproducibility in the measurement of central corneal thickness
    Albe, E
    Miglior, S
    Guareschi, M
    Mandelli, G
    Gomarasca, S
    Orzalesi, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U512 - U512
  • [9] Intra and inter-observer variability in the scoring of micronuclei in binucleated human lymphocytes
    Patino-Garcia, B.
    Varga, D.
    Hoehne, M.
    Michel, I.
    Kreienberg, R.
    Jainta, S.
    Maier, C.
    Vogel, W.
    CHROMOSOME RESEARCH, 2005, 13 : 116 - 116
  • [10] MR evaluation of epidural fibrosis: Proposed grading system with intra- and inter-observer variability
    Ross, JS
    Obuchowski, N
    Modic, MT
    NEUROLOGICAL RESEARCH, 1999, 21 : S23 - S26