An Evaluation of an Aftermarket Local Exhaust Ventilation Device for Suppressing Respirable Dust and Respirable Crystalline Silica Dust from Powered Saws

被引:8
|
作者
Garcia, Alberto [1 ]
Jones, Erica [1 ]
Echt, Alan S. [1 ]
Hall, Ronald M. [1 ]
机构
[1] NIOSH, DART, Cincinnati, OH 45226 USA
关键词
D O I
10.1080/15459624.2014.955182
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric-powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits (OELs). Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who only lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m(3)) with a geometric mean of 0.38 mg/m(3) for roofers and from 0.45 to 3.82 mg/m(3) with a geometric mean of 1.84 mg/m(3) for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m(3) with a geometric mean of 0.09 mg/m(3) for roofers, and from 0.13 to 1.21 mg/m(3) with a geometric mean of 0.48 mg/m(3) for cutters/roofers. As with respirable dust, the respirable silica exposures for cutters/roofers were higher than the exposures for roofers.
引用
收藏
页码:D200 / D207
页数:8
相关论文
共 50 条
  • [31] QUANTITATIVE-DETERMINATION OF CRYSTALLINE SILICA IN RESPIRABLE-SIZE DUST SAMPLES BY INFRARED SPECTROPHOTOMETRY
    FOSTER, RD
    WALKER, RF
    ANALYST, 1984, 109 (09) : 1117 - 1127
  • [32] Surveillance of respirable crystalline silica dust using OSHA compliance data (1979-1995)
    Linch, KD
    Miller, WE
    Althouse, RB
    Groce, DW
    Hale, JM
    AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1998, 34 (06) : 547 - 558
  • [33] Characterizing and Comparing Emissions of Dust, Respirable Crystalline Silica, and Volatile Organic Compounds from Natural and Artificial Stones
    Hall, Samantha
    Stacey, Peter
    Pengelly, Ian
    Stagg, Stephen
    Saunders, John
    Hambling, Susan
    ANNALS OF WORK EXPOSURES AND HEALTH, 2022, 66 (02) : 139 - 149
  • [34] The Evaluation and Quantification of Respirable Coal and Silica Dust Concentrations: A Task-based Approach
    Grove, T.
    Van Dyk, T.
    Franken, A.
    Du Plessis, J.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2014, 11 (06) : 406 - 414
  • [35] Laboratory Evaluation to Reduce Respirable Crystalline Silica Dust When Cutting Concrete Roofing Tiles Using a Masonry Saw
    Carlo, Rebecca V.
    Sheehy, John
    Feng, H. Amy
    Sieber, William K.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (04) : 245 - 251
  • [36] Exposure-Response Association between Cumulative Exposure to Respirable Crystalline Silica Dust and Lung Cancer
    Morfeld, Peter
    ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2013, 63 (06): : 342 - 346
  • [37] Analysis of the Silica Percent in Airborne Respirable Mine Dust Samples From US Operations
    Cauda, Emanuele
    Joy, Gerald
    Miller, Arthur
    Mischler, Steven
    SILICA AND ASSOCIATED RESPIRABLE MINERAL PARTICLES, 2014, 1565 : 12 - 27
  • [38] RADIOLOGICAL REVIEW OF QUEENSLAND MINERS WITH PNEUMOCONIOSIS FOLLOWING OCCUPATIONAL EXPOSURE TO COAL DUST WITH OR WITHOUT RESPIRABLE CRYSTALLINE SILICA
    Newbigin, K.
    Parsons, R.
    McBean, R.
    Discroll, T.
    RESPIROLOGY, 2019, 24 : 58 - 58
  • [39] Benefits and limitations of field-based monitoring approaches for respirable dust and crystalline silica applied in a sandstone quarry
    Cauda, Emanuele
    Dolan, Eric
    Cecala, Andrew
    Louk, Kyle
    Yekich, Milan
    Chubb, Lauren
    Lingenfelter, Andrew
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2022, 19 (12) : 730 - 741
  • [40] Unique water spray system improves exhaust face ventilation and reduces exposure to respirable dust on continuous miners in laboratory tests
    Page, Steven J.
    Mal, Thomas
    Volkwein, Jon C.
    Journal of the Mine Ventilation Society of South Africa, 1994, 47 (10) : 196 - 205