Design and implemention of a multi-functional X-ray Computed Tomography system

被引:0
|
作者
Li, Lei [1 ]
Xi, Xiaoqi [1 ]
Han, Yu [1 ]
Yan, Bin [1 ]
Zhang, Xiang [1 ]
Deng, Lin [1 ]
Chen, Siyu [1 ]
Jin, Zhao [1 ]
Li, Zengguang [1 ]
机构
[1] Natl Digital Switching Syst Engn & Technol Res Ct, Zhengzhou 450000, Peoples R China
关键词
nondestructive testing; three-dimensional; computed tomography; engine block;
D O I
10.1117/12.2202998
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A powerful volume X-ray tomography system has been designed and constructed to provide an universal tool for the three-dimensional nondestructive testing and investigation of industrial components, automotive, electronics, aerospace components, new materials, etc. The combined system is equipped with two commercial X-ray sources, sharing one flat panel detector of 400mmx400mm. The standard focus 450kV high-energy x-ray source is optimized for complex and high density components such as castings, engine blocks and turbine blades. And the microfocus 225kV x-ray source is to meet the demands of micro-resolution characterization applications. Thus the system's penetration capability allows to scan large objects up to 200mm thick dense materials, and the resolution capability can meet the demands of 20 mu m microstructure inspection. A high precision 6-axis manipulator system is fitted, capable of offset scanning mode in large field of view requirements. All the components are housed in a room with barium sulphate cement. On the other hand, the presented system expands the scope of applications such as dual energy research and testing. In this paper, the design and implemention of the flexible system is described, as well as the preliminary tomographic imaging results of an automobile engine block.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [42] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [43] Image Analysis in X-ray Computed Tomography
    Seletchi, Emilia Dana
    Sutac, Victor
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING: VIRTUAL LEARNING - VIRTUAL REALITY: MODELS & METHODOLOGIES, TECHNOLOGIES, SOFTWARE SOLUTIONS, 2006, : 187 - +
  • [44] Ptychographic X-ray computed tomography at the nanoscale
    Dierolf, Martin
    Menzel, Andreas
    Thibault, Pierre
    Schneider, Philipp
    Kewish, Cameron M.
    Wepf, Roger
    Bunk, Oliver
    Pfeiffer, Franz
    NATURE, 2010, 467 (7314) : 436 - U82
  • [45] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    JOURNAL OF IMAGING, 2022, 8 (05)
  • [46] Signal statistics of x-ray computed tomography
    Whiting, BR
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 53 - 60
  • [47] NOISE LIMITATIONS IN X-RAY COMPUTED TOMOGRAPHY
    TRETIAK, OJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 477 - 480
  • [48] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    Nature, 2010, 467 : 436 - 439
  • [49] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [50] X-ray computed tomography of polymer composites
    Garcea, S. C.
    Wang, Y.
    Withers, P. J.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 156 : 305 - 319