Blood pool agent contrast-enhanced MRA: Level-set based artery-vein separation

被引:1
|
作者
van Bemmela, CM [1 ]
Spreeuwers, L [1 ]
Verdonck, B [1 ]
Viergever, MA [1 ]
Niessen, WJ [1 ]
机构
[1] Univ Utrecht, Med Ctr, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
blood pool agent; contrast-enhanced MRA; segmentation;
D O I
10.1117/12.467112
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood pool agents (BPAs) for contrast-enhanced magnetic resonance angiograpliy (CE-MRA) allow prolonged imaging times for higher contrast and resolution by imaging during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous arterial and venous enhancement hampers interpretation. It is shown that venous and arterial segmentation in this equilibrium phase can be achieved if the central arterial axis (CAA) and central venous axis (CVA) are known. Since the CAA cannot straightforwardly be obtained from the steady-state data, images acquired during the first pass of the contrast agent can be utilized to determine the CAA with minimal user initialization. Utilizing the CAA to provide a rough arterial segmentation, the CVA can subsequently be determined from the steady-state dataset. The final segmentations of the arteries and veins are achieved by simultaneously evolving two level-sets in the steady-state dataset starting from the CAA and CVA.
引用
收藏
页码:1464 / 1475
页数:12
相关论文
共 35 条
  • [21] Extended blood circulation of a macromolecular gadolinium-based T1 contrast agent for vascular dynamic contrast-enhanced magnetic resonance imaging
    Jenjob, Ratchapol
    Kun, Na
    Ghee, Jung Yeon
    Lee, Don Haeng
    Yang, Su-Geun
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2016, 12 (02) : 504 - 504
  • [22] PULMONARY BLOOD FLOW ANALYSIS BASED ON TWO INPUT MODEL WITH AORTA AND PULMONARY ARTERY CONTRIBUTI ON USING CONTRAST-ENHANCED MRI
    Ichikawa, M.
    Gotoh, T.
    Kagei, S.
    Iwasawa, T.
    Tsuzuki, M. S. G.
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 882 - 885
  • [23] A Computer-Aided Diagnosis System for Dynamic Contrast-Enhanced MR Images Based on Level Set Segmentation and ReliefF Feature Selection
    Pang, Zhiyong
    Zhu, Dongmei
    Chen, Dihu
    Li, Li
    Shao, Yuanzhi
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2015, 2015
  • [24] Contrast-enhanced magnetic resonance angiography - P792 blood pool agent versus Gd-DOTA in rabbits at 3.0 T versus 1.5 T
    Herborn, Christoph U.
    Watkins, David M.
    Baumann, Shannon
    Robert, Philippe
    Corot, Claire
    Runge, Val M.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (09) : 622 - 628
  • [25] High-resolution 3D volumetric contrast-enhanced MR angiography with a blood pool agent (ferumoxytol) for diagnostic evaluation of pediatric brain arteriovenous malformations
    Iv, Michael
    Choudhri, Omar
    Dodd, Robert L.
    Vasanawala, Shreyas S.
    Alley, Marcus T.
    Moseley, Michael
    Holdsworth, Samantha J.
    Grant, Gerald
    Cheshier, Samuel
    Yeom, Kristen W.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2018, 22 (03) : 251 - 260
  • [26] Effect of a galactose-based contrast agent on the blood flow velocity of the portal vein and the hepatic artery measured by means of Doppler ultrasound
    Schiedermaier, P
    Biecker, E
    Sauerbruch, T
    GASTROENTEROLOGY, 1999, 116 (04) : A926 - A926
  • [27] Contrast-enhanced MR angiography (MRA) with temporary occluded unilateral common carotid artery (CCA) manually to evaluate cerebral blood flow: Comparison with conventional balloon occluded test (BTO)
    Hori, M
    Aoki, S
    Okubo, T
    Araki, T
    Hirasawa, N
    Hayasaka, T
    RADIOLOGY, 2001, 221 : 440 - 441
  • [28] Dynamic contrast-enhanced QSM for perfusion imaging: a systematic comparison of ΔR2*- and QSM-based contrast agent concentration time curves in blood and tissue
    Emelie Lind
    Linda Knutsson
    Freddy Ståhlberg
    Ronnie Wirestam
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 663 - 676
  • [29] Dynamic contrast-enhanced QSM for perfusion imaging: a systematic comparison of ΔR2*- and QSM-based contrast agent concentration time curves in blood and tissue
    Lind, Emelie
    Knutsson, Linda
    Stahlberg, Freddy
    Wirestam, Ronnie
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (05) : 663 - 676
  • [30] Renal functional contrast-enhanced magnetic resonance imaging - Evaluation of a new rapid-clearance blood pool agent (P792) in Sprague-Dawley rats
    Mandry, D
    Pedersen, M
    Odille, F
    Robert, P
    Corot, C
    Felblinger, J
    Grenier, N
    Claudon, M
    INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 295 - 305