Effects of hemolysis and lipemia interference on kaolin-activated thromboelastography, and comparison with conventional coagulation tests

被引:12
|
作者
Tang, Ning [1 ]
Jin, Xi [1 ]
Sun, Ziyong [1 ]
Jian, Cui [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Clin Lab, Wuhan, Hubei, Peoples R China
来源
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION | 2017年 / 77卷 / 02期
关键词
Coagulation test; hemolysis; lipemia; quality management; thromboelastography; FACTOR-VII; BLOOD; SPECIFICATIONS; QUALITY; PLASMA;
D O I
10.1080/00365513.2016.1271906
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The effects of hemolysis and lipemia on thromboelastography (TEG) analysis have been scarcely evaluated in human samples, and neglected in clinical practice. We aimed to investigate the effects of in vitro mechanical hemolysis and lipemia on TEG analysis and conventional coagulation tests. Twenty-four healthy volunteers were enrolled in the study. Besides the controls, three groups with slight, moderate and severe mechanical hemolysis were constituted according to free hemoglobin (Hb) concentrations of 0.5-1.0, 2.0-6.0 and 7.0-13.0g/L, respectively; and three groups with mild, moderate and high lipemia were established according to triglyceride concentrations of approximate to 6.0, approximate to 12.0, and approximate to 18.0mmol/L, respectively. Four TEG parameters, reaction time (R), coagulation time (K), angle (), and maximum amplitude (MA), were measured alongside conventional plasma tests including prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FIB) by mechanical method, and platelet count by optical method. Results showed that the median R and MA values at moderate and severe hemolysis and K at severe hemolysis exceeded respective reference intervals, and were considered unacceptable. Median values of TEG parameters in lipemic samples were all within reference intervals. Bias values of conventional plasma tests PT, APTT and FIB in hemolyzed or lipemic samples were all lower than the Clinical Laboratory Improvement Amendments (CLIA) allowable limits. Bias values of platelet count at moderate to severe hemolysis and lipemia exceeded the CLIA allowable limits. In conclusion, the detection of TEG was in general more affected by mechanical hemolysis than plasma coagulation tests. Pre-analytical variables should be taken into account when unexpected TEG results are obtained.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 50 条
  • [41] Clinical evaluation of hypercoagulability in advanced malignant tumors using thromboelastography and conventional coagulation tests
    Yang, Jinzhu
    Shen, Lei
    MEDICINE, 2025, 104 (06)
  • [42] Obstetric Hemorrhage and Coagulation: An Update. Thromboelastography, Thromboelastometry, and Conventional Coagulation Tests in the Diagnosis and Prediction of Postpartum Hemorrhage
    de Lange, Natascha M.
    Lance, Marcus D.
    de Groot, Renee
    Beckers, Erik A. M.
    Henskens, Yvonne M.
    Scheepers, Hubertina C. J.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2012, 67 (07) : 426 - 435
  • [43] Comparison between thromboelastography and conventional coagulation assays in patients with deep vein thrombosis
    Mao, Chaoqin
    Xiong, Yueshan
    Fan, Cheng
    CLINICA CHIMICA ACTA, 2021, 520 : 208 - 213
  • [44] Effects of Hemolysis on Routine Coagulation Tests when Tested on an Optical Coagulation Analyzer
    Yang, Hao
    Zhao, Yijia
    Guo, Siqi
    He, Jiajing
    Peng, Luyun
    Wang, Yuefang
    Zhang, Ge
    Jiang, Yongmei
    CLINICAL LABORATORY, 2023, 69 (08) : 1601 - 1606
  • [45] Thromboelastography in mild, chronic liver disease: challenging conventional coagulation tests preceding liver biopsy
    Veronese, L. R.
    Miller, M.
    Spearman, W. C.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2018, 24 (05) : 135 - 139
  • [46] Correlation of early rotation thromboelastography parameters with conventional coagulation tests in patients undergoing liver transplantation
    Guerrero, M.
    Garcia, A.
    Garcia, M.
    Elices, R.
    Martinez, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 107 - 107
  • [47] Effects of recombinant activated factor VII on coagulation measured by thromboelastography in liver transplantation
    Hendriks, HGD
    Meijer, K
    de Wolf, JTM
    Porte, RJ
    Klompmaker, IJ
    Lip, H
    Slooff, MJH
    van der Meer, J
    BLOOD COAGULATION & FIBRINOLYSIS, 2002, 13 (04) : 309 - 313
  • [48] Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients
    Liu, Chen
    Guan, Zhao
    Xu, Qinzhu
    Zhao, Lei
    Song, Ying
    Wang, Hui
    MEDICINE, 2016, 95 (24)
  • [49] A retrospective comparison of thromboelastography and conventional coagulation parameters for periprosthetic joint infection diagnosis and reimplantation timing
    Qiao, Li
    Sun, Shui
    CLINICA CHIMICA ACTA, 2021, 519 : 118 - 125
  • [50] Comparison of conventional tests with thromboelastography (TEG) in assessing bleeding risk in decompensated cirrhosis patients
    Xavier, Edward
    Park, Sang-Hoon
    Patrie, James
    Hespenheide, Elizabeth E.
    Northup, Patrick G.
    Al-Osaimi, Abdullah M.
    Macik, Gail
    Manuel, Gary L.
    Mintz, Paul
    Caldwell, Stephen H.
    May, Daniel S.
    Park, Choong-Kee
    HEPATOLOGY, 2007, 46 (04) : 588A - 588A