Wear, oxidation and mechanical properties of a sequentially irradiated and annealed UHMWPE in total joint replacement

被引:70
|
作者
Wang, A.
Zeng, H.
Yau, S-S
Essner, A.
Manely, M.
Dumbleton, J.
机构
[1] Stryker Orthopaed, Mahwah, NJ 07430 USA
[2] Bioengn Consultant, Ridgewood, NJ 07450 USA
[3] Consultancy Med Devices, Ridgewood, NJ 07450 USA
关键词
D O I
10.1088/0022-3727/39/15/S12
中图分类号
O59 [应用物理学];
学科分类号
摘要
Ultra high molecular weight polyethylene (UHMWPE) has been used as a bearing surface in joint replacement prostheses for over 40 years. Recently, highly crosslinked UHMWPE (HXPE) materials were introduced based on the finding that crosslinking reduces wear. These first generation HXPE materials were produced by irradiation followed by heating below the melting temperature (annealing) or above the melting temperature (remelting). Both classes of HXPE material have demonstrated greatly reduced wear. However, remelted HXPE materials have reduced fatigue strength while annealed HXPE materials may oxidize when exposed to oxygen. A second generation HXPE material was produced using a sequential irradiation and annealing process (SXL). SXL materials have crosslinking levels equivalent to those of first generation HXPE materials, have fatigue and mechanical strength characteristics of first generation annealed HXPE material and have an oxidation resistance equivalent to that of virgin (unprocessed) UHMWPE. This combination of properties makes SXL HXPE a preferred material for bearing surfaces of joint prostheses.
引用
收藏
页码:3213 / 3219
页数:7
相关论文
共 50 条
  • [41] Effect of γ-ray irradiation on the oxidation of UHMWPE used in total joint arthroplasty.
    Tasy, R
    Lin, CW
    Won, WM
    Laiw, HH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U463 - U464
  • [42] Investigation of an Approach to Balance Wear Resistance and Mechanical Properties of Crosslinked UHMWPE
    Schwartz, Christian J.
    Bahadur, Shyam
    TRIBOLOGY LETTERS, 2009, 34 (02) : 125 - 131
  • [43] Investigation of an Approach to Balance Wear Resistance and Mechanical Properties of Crosslinked UHMWPE
    Christian J. Schwartz
    Shyam Bahadur
    Tribology Letters, 2009, 34 : 125 - 131
  • [44] European Database of Explanted UHMWPE Liners from Total Joint Replacements: Correlations among Polymer Modifications, Structure, Oxidation, Mechanical Properties and Lifetime In Vivo
    Slouf, Miroslav
    Gajdosova, Veronika
    Dybal, Jiri
    Sticha, Roman
    Fulin, Petr
    Pokorny, David
    Mateo, Jesus
    Jose Panisello, Juan
    Canales, Vicente
    Medel, Francisco
    Bistolfi, Alessandro
    Bracco, Pierangiola
    POLYMERS, 2023, 15 (03)
  • [45] The Risk of Total Joint Replacement Infectious Complications in Relation to the UHMWPE Particle Adhesion Area
    Fulin, P.
    Slouf, M.
    Krejcikova, S.
    Hromadkova, J.
    Jahoda, D.
    Pokorny, D.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2019, 86 (06) : 397 - 402
  • [46] Long-term wear failure analysis of uhmwpe acetabular cup in total hip replacement
    Shahemi, N.
    Liza, S.
    Abbas, A. A.
    Merican, A. M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 87 : 1 - 9
  • [47] A study of the wear resistance of three types of clinically applied UHMWPE for total replacement hip prostheses
    Barbour, PSM
    Stone, MH
    Fisher, J
    BIOMATERIALS, 1999, 20 (22) : 2101 - 2106
  • [48] Effects of gamma irradiation and accelerated aging on wear properties of UHMWPE artificial joint
    Kaneeda, T
    Utsumi, M
    Watanabe, E
    PROCEEDINGS OF THE FOURTEENTH ANNUAL MEETING OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1999, : 167 - 170
  • [49] Oxidation, Damage Mechanisms, and Reasons for Revision of Sequentially Annealed Highly Crosslinked Polyethylene in Total Knee Arthroplasty
    MacDonald, Daniel W.
    Higgs, Genymphas B.
    Chen, Antonia F.
    Malkani, Arthur L.
    Mont, Michael A.
    Kurtz, Steven M.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1235 - 1241
  • [50] Restricting the ageing degradation of the mechanical properties of gamma irradiated UHMWPE using MWCNTs
    Sreekanth, P. S. Rama
    Kanagaraj, S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 21 : 57 - 66