Comparability of three-dimensional optic disc imaging with different techniques - A study with confocal scanning laser tomography and raster tomography

被引:1
|
作者
Gundersen, KG [1 ]
Heijl, A [1 ]
Bengtsson, B [1 ]
机构
[1] Malmo Univ Hosp, Dept Ophthalmol, S-20502 Malmo, Sweden
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2000年 / 78卷 / 01期
关键词
optic disc topography; scanning laser tomography; raster tomography; glaucoma diagnosis;
D O I
10.1034/j.1600-0420.2000.078001009.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We wanted to compare optic nerve head topography measurements and discrimination between normal and glaucomatous eyes with two entirely different three-dimensional optic disc imaging techniques, confocal scanning laser tomography (Heidelberg Retina Tomograph, Heidelberg Engineering) and raster tomography (Glaucoma-Scope, Ophthalmic Imaging Systems). Methods: Both eyes of 225 normal subjects and 229 eyes of 166 patients with glaucoma at different stages were imaged with the Heidelberg Retina Tomograph and the Glaucoma-Scope. Optics discs were analysed in 15 degrees sectors around the circumference. Depth measurements were calibrated on objects with known dimensions. Results: We observed no significant differences in absolute measurements of maximum cup depth and cup area between the two instruments. We observed small differences in absolute measurements of disc anti rim area between the two instruments. Discrimination between normal and glaucomatous eyes was close to identical for the two instruments. Both instruments had the same ability to distinguish glaucomatous regional alterations of optic nerve head topography from normal disc configuration. Conclusion: Both instruments while using entirely different principles for three-dimensional optic disc imaging gave very similar results. This correspondence of results implies that the same optic disc parameters can be analysed, and the results interpreted similarly for both methods, and probably with other three-dimensional imaging instruments. It may also indicate that results of studies with one of the instruments have general validity.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 50 条
  • [41] A comparison of optic disc area measured by confocal scanning laser tomography versus Bruch’s membrane opening area measured using optical coherence tomography
    Ioana Maria Cazana
    Daniel Böhringer
    Thomas Reinhard
    Charlotte Evers
    Diana Engesser
    Alexandra Anton
    Jan Lübke
    BMC Ophthalmology, 21
  • [42] A comparison of optic disc area measured by confocal scanning laser tomography versus Bruch's membrane opening area measured using optical coherence tomography
    Cazana, Ioana Maria
    Boehringer, Daniel
    Reinhard, Thomas
    Evers, Charlotte
    Engesser, Diana
    Anton, Alexandra
    Luebke, Jan
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [43] Better assessment of scanning laser tomography through three-dimensional spatial presentation.
    Müller-Richter, UD
    Ruprecht, KW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S18 - S18
  • [44] Computed tomography scanning for three-dimensional imaging and complexity analysis of developing root systems
    Lontoc-Roy, M
    Dutilleul, P
    Prasher, SO
    Han, LW
    Smith, DL
    CANADIAN JOURNAL OF BOTANY-REVUE CANADIENNE DE BOTANIQUE, 2005, 83 (11): : 1434 - 1442
  • [45] Scanning precession electron tomography for three-dimensional nanoscale orientation imaging and crystallographic analysis
    Alexander S. Eggeman
    Robert Krakow
    Paul A. Midgley
    Nature Communications, 6
  • [46] Scanning precession electron tomography for three-dimensional nanoscale orientation imaging and crystallographic analysis
    Eggeman, Alexander S.
    Krakow, Robert
    Midgley, Paul A.
    NATURE COMMUNICATIONS, 2015, 6
  • [47] Line-field confocal optical coherence tomography compared with confocal laser scanning microscopy: A pilot study on three different age groups
    Bellemere, G.
    Boyer, G.
    De Belilovsky, C.
    Pinto, P.
    Barut, A.
    Pedrazzani, M.
    Tavernier, C.
    Baudouin, C.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2023, 143 (05) : S136 - S136
  • [48] Line-Field Confocal Optical Coherence Tomography compared with Confocal Laser Scanning Microscopy: a pilot study on three different age groups
    Boyer, G.
    De Belilosky, C.
    Pinto, P.
    Barut, A.
    Pedrazzani, M.
    Tavernier, C.
    Bellemere, G.
    Baudouin, C.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2022, 142 (12) : S218 - S218
  • [49] Optic nerve head morphometry in healthy adults using confocal laser scanning tomography
    Hermann, MM
    Theofylaktopoulos, I
    Bangard, N
    Jonescu-Cuypers, C
    Coburger, S
    Diestelhorst, M
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (06) : 761 - 765
  • [50] Optic nerve head screening with confocal laser scanning tomography in healthy adults.
    Hermann, MM
    Theofylaktopoulos, I
    Jonescu-Cuypers, CP
    Bangard, N
    Diestelhorst, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S18 - S18