Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance

被引:3
|
作者
Setiadi, Rahmondia N. [1 ,2 ]
Schilling, Meinhard [1 ]
机构
[1] TU Braunschweig, Inst Elekt Messtech & Grundlagen Elektrotech, Hans Sommer Str 66, D-38106 Braunschweig, Germany
[2] Univ Riau, Fac Math & Nat Sci, Phys Study Program, Pekanbaru 28293, Indonesia
关键词
impedance measurement; inductance; auto-balanced circuit; fluxgate sensor; SENSORS;
D O I
10.1088/1361-6501/aaae97
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.
引用
收藏
页数:9
相关论文
共 38 条
  • [1] Sensitive Faraday rotation measurement with auto-balanced photodetection
    Chang, Chia-Yu
    Wang, Likarn
    Shy, Jow-Tsong
    Lin, Chu-En
    Chou, Chien
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (06):
  • [2] Cavity-enhanced Faraday rotation measurement with auto-balanced photodetection
    Chang, Chia-Yu
    Shy, Jow-Tsong
    APPLIED OPTICS, 2015, 54 (28) : 8526 - 8530
  • [3] Measurement of cerebral edema using an impedance analyzer circuit
    Harting, Matthew
    Smith, Carter
    Radhakrishnan, Ravi
    Dash, Pramod
    Gill, Bryesh
    Cox, Charles, Jr.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2007, 205 (03) : S35 - S35
  • [4] Measurement of intestinal edema using an impedance analyzer circuit
    Radhakrishnan, Ravi S.
    Shah, Kunal
    Xue, Hasen
    Moore-Olufemi, Stacey D.
    Moore, Frederick A.
    Weisbrodt, Norman W.
    Allen, Steven J.
    Gill, Brijesh
    Cox, Charles S., Jr.
    JOURNAL OF SURGICAL RESEARCH, 2007, 138 (01) : 106 - 110
  • [5] Measures of improving the precision of amplitude modulation measurement circuit of inductance sensor
    Zhao, W.Q.
    Tan, J.B.
    Liu, B.F.
    Yang, W.G.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2001, 22 (03):
  • [6] Biomaterial Impedance Analyzer Based on Digital Auto Balancing Bridge
    Li, Nan
    Wang, Yinan
    Nie, Hongshan
    Yu, Hongqi
    Xu, Hui
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1259 - 1262
  • [7] Minimally invasive measurement of intestinal edema using an impedance analyzer circuit
    Radhakrishnan, Ravi S.
    Shah, Kunal
    Xue, Hasen
    Moore, Frederick A.
    Weisbrodt, Norman W.
    Gill, Brijesh S.
    Cox, Charles S.
    GASTROENTEROLOGY, 2006, 130 (04) : A477 - A477
  • [8] Backside Thermal Fault Localization Using Laser Scanning Confocal Thermoreflectance Microscopy Based on Auto-Balanced Detection
    Kim, Dong Uk
    Kim, Jung Dae
    Han, Ilkyu
    Jeong, Chan Bae
    Lee, Kye-Sung
    Hur, Hwan
    Nam, Ki-Hwan
    Bae, Ji Yong
    Kim, I. Jong
    Chang, Ki Soo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) : 2914 - 2923
  • [9] A compact wideband precision impedance measurement system based on digital auto-balancing bridge
    Hu, Binxin
    Wang, Jinyu
    Song, Guangdong
    Zhang, Faxiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (05)
  • [10] Light-shift mitigation in a microcell-based atomic clock with symmetric auto-balanced Ramsey spectroscopy
    Hafiz, M. Abdel
    Carle, C.
    Passilly, N.
    Danet, J. M.
    Calosso, C. E.
    Boudot, R.
    APPLIED PHYSICS LETTERS, 2022, 120 (06)