Sensitive Faraday rotation measurement with auto-balanced photodetection

被引:23
|
作者
Chang, Chia-Yu [1 ]
Wang, Likarn [1 ]
Shy, Jow-Tsong [1 ,2 ]
Lin, Chu-En [3 ]
Chou, Chien [3 ,4 ,5 ]
机构
[1] Natl Tsing Hua Univ, Inst Photon Technol, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Phys, Hsinchu, Taiwan
[3] Natl Cent Univ, Dept Opt & Photon, Jhongli, Taiwan
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
[5] Natl Yang Ming Univ, Inst Biophoton, Taipei 112, Taiwan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2011年 / 82卷 / 06期
关键词
D O I
10.1063/1.3602927
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A magneto-optic polarimetry based on auto-balanced photodetection is investigated. In this experiment, a commercial auto-balanced photoreceiver is adopted to measure the Faraday rotation of air. With a proper setup to utilize its noise cancellation capability, the measurement can be flexible and sensitive. The angular sensitivity is 2.99x10(-8) rad Hz(-1/2), which is about 2.7 times the shot noise limit. The measured Verdet constant of air is +1.39x10(-9) rad G(-1) cm(-1) at 634.8 nm. Significantly we applied a small AC current to induce the magnetic field, so there was no heating in the coil. In addition, a double current modulation scheme was used to demonstrate that there was no zero drift and amplifier instability in the measurement. The possibility of improvement of the angular sensitivity and the potential applications are also discussed. (C) 2011 American Institute of Physics. [doi:10.1063/1.3602927]
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Cavity-enhanced Faraday rotation measurement with auto-balanced photodetection
    Chang, Chia-Yu
    Shy, Jow-Tsong
    APPLIED OPTICS, 2015, 54 (28) : 8526 - 8530
  • [2] Auto-balanced common shock claim models
    Taylor, Greg
    Vu, Phuong Anh
    ANNALS OF ACTUARIAL SCIENCE, 2023, 17 (03) : 580 - 605
  • [3] Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance
    Setiadi, Rahmondia N.
    Schilling, Meinhard
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (05)
  • [4] A Smart Auto-Balanced System for Incubation Process
    Juel, Md. Tarikul Islam
    Ahmed, Md. Sajid
    2019 1ST INTERNATIONAL CONFERENCE ON ROBOTICS, ELECTRICAL AND SIGNAL PROCESSING TECHNIQUES (ICREST), 2019, : 558 - 563
  • [5] Faraday Rotation Spectroscopic Sensing of Oxygen using Static Magnetic Fields and Balanced Photodetection
    So, Stephen G.
    Jeng, Evan
    Wysocki, Gerard
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [6] Auto-Balanced Filter Pruning for Efficient Convolutional Neural Networks
    Ding, Xiaohan
    Ding, Guiguang
    Han, Jungong
    Tang, Sheng
    THIRTY-SECOND AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE / THIRTIETH INNOVATIVE APPLICATIONS OF ARTIFICIAL INTELLIGENCE CONFERENCE / EIGHTH AAAI SYMPOSIUM ON EDUCATIONAL ADVANCES IN ARTIFICIAL INTELLIGENCE, 2018, : 6797 - 6804
  • [7] Scanning magneto-optical Kerr microscope with auto-balanced detection scheme
    Halahovets, Y.
    Siffalovic, P.
    Jergel, M.
    Senderak, R.
    Majkova, E.
    Luby, S.
    Kostic, I.
    Szymanski, B.
    Stobiecki, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08):
  • [8] Performance Analysis of Input Voltage Auto-Balanced LLC Converter with Resonant Switched Capacitor
    Luo, Qingjing
    Zong, Sheng
    Luo, Haoze
    Zhao, Yi
    Li, Wuhua
    He, Xiangning
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1 - 5
  • [9] MEASUREMENT OF FARADAY-ROTATION IN IHX
    JARBOE, TR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (10): : 1320 - 1320
  • [10] Measurement of Faraday rotation using phase-sensitive low-coherence interferometry
    Al-Qaisi, Muhammad K.
    Wang, Hui
    Akkin, Taner