Study of a solvent extraction type of absorption heat pump

被引:1
|
作者
Cheng, CS [1 ]
机构
[1] Lunghwa Inst Technol, Dept Chem Engn, Tao Yuan 330, Taiwan
关键词
D O I
10.1016/S0196-8904(99)00113-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
The coefficient of performance for the cooling cycle COPc and for the heating cycle COPh of a traditional absorption heat pump (AHP), defined as COPc = \ Q(E)/(Q(G) + W)\ and COPh = \(Q(A) + Q(C))/(Q(G) + W)\, usually has a value less than 0.80 for a cooling system and less than 1.80 for a heating system. This paper proposes a new type of absorption heat pump that employs a second liquid to extract the refrigerant from the dilute absorbent solution in the absorber (EXAHP system). The proposed system achieves COPc and COPh values that exceed those values in a tradition absorption heat pump. The calculated COPc and COPh values reach as high as 1.6 and 2.3, respectively which are approximately 100% and 50% higher than those of the conventional systems. Using LiBr/H2O/acetophenone as an example, this paper presents the concept design and operation analysis of the proposed plant. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:727 / 736
页数:10
相关论文
共 50 条
  • [21] Design of Absorption-Heat-Pump Heat Exchangers
    Garimella, Srinivas
    Coleman, John W.
    Wicht, Andreas
    JOURNAL OF ENHANCED HEAT TRANSFER, 2017, 24 (1-6) : 211 - 229
  • [22] UPGRADING HEAT BY A REVERSED ABSORPTION HEAT-PUMP
    KIATSIRIROAT, T
    BHATTACHARYA, SC
    WIBULSWAS, P
    APPLIED ENERGY, 1986, 25 (03) : 175 - 186
  • [23] Study of an advanced absorption heat pump using untapped energy resources
    Okamoto, Hiroaki
    Dang, Chaobin
    Hihara, Eiji
    Ichikawa, Toru
    Oka, Masahiro
    Kojima, Hiroshi
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 315 - +
  • [24] Performance analysis of a plate type heat exchanger used as absorber in a combined compression/absorption heat pump
    Nordtvedt, SR
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 235 - 239
  • [25] SIMULATION OF THE PERFORMANCE CHARACTERISTICS OF THE ABSORPTION-TYPE HEAT PUMP FOR TEMPERATURE BOOSTING OF WASTE HEAT.
    Kashiwagi, Takao
    Itoh, Shinji
    Kurosaki, Yasuo
    Katoh, Toshiharu
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1986, 52 (474): : 795 - 800
  • [26] MODULAR ABSORPTION HEAT-PUMP WITH THERMAL SOLUTION PUMP
    KNOCHE, KF
    STRAUSS, R
    LANG, R
    CHEMIE INGENIEUR TECHNIK, 1992, 64 (04) : 351 - 352
  • [27] Thermodynamic Optimization Characteristics of a Type I Absorption Heat Pump within Finite Time
    Zhao, Xiling
    Li, Yan
    Fu, Lin
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4250 - 4253
  • [28] Experimental study and analysis on double effect absorption heat pump for efficient waste heat recovery
    Xu, Zhenyuan
    Mao, Hongcai
    Liu, Dianshou
    Wang, Ruzhu
    CHINESE SCIENCE BULLETIN-CHINESE, 2020, 65 (16): : 1618 - 1626
  • [29] Thermodynamic Performance Study of CaCl2 Absorption Heat Pump Heat Storage System
    Chen, Jinsen
    Liu, Jiping
    Zhao, Yongliang
    Zhang, Lanjie
    Zhang, Shunqi
    Yan, Junjie
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (11): : 3069 - 3075
  • [30] HEAT-PUMP ASSISTED DISTILLATION .5. A FEASIBILITY STUDY ON ABSORPTION HEAT-PUMP ASSISTED DISTILLATION SYSTEMS
    EISA, MAR
    BEST, R
    DIGGORY, PJ
    HOLLAND, FA
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1987, 11 (02) : 179 - 191