Numerical and Structural Genomic Aberrations Are Reliably Detectable in Tissue Microarrays of Formalin-Fixed Paraffin-Embedded Tumor Samples by Fluorescence In-Situ Hybridization

被引:17
|
作者
Horn, Heike [1 ,2 ]
Bausinger, Julia [1 ,2 ]
Staiger, Annette M. [1 ,2 ]
Sohn, Maximilian [1 ,2 ]
Schmelter, Christopher [3 ]
Gruber, Kim [1 ,2 ]
Kalla, Claudia [1 ,2 ]
Ott, M. Michaela [4 ]
Rosenwald, Andreas [3 ]
Ott, German [1 ,2 ]
机构
[1] Robert Bosch Krankenhaus, Dept Clin Pathol, Stuttgart, Germany
[2] Dr Margarete Fischer Bosch Inst Clin Pharmacol, Stuttgart, Germany
[3] Univ Wurzburg, Inst Pathol, Wurzburg, Germany
[4] Caritas Hosp, Inst Pathol, Bad Mergentheim, Germany
来源
PLOS ONE | 2014年 / 9卷 / 04期
关键词
MANTLE CELL LYMPHOMA; AMPLIFICATIONS; ABNORMALITIES; DELETIONS;
D O I
10.1371/journal.pone.0095047
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Few data are available regarding the reliability of fluorescence in-situ hybridization (FISH), especially for chromosomal deletions, in high-throughput settings using tissue microarrays (TMAs). We performed a comprehensive FISH study for the detection of chromosomal translocations and deletions in formalin-fixed and paraffin-embedded (FFPE) tumor specimens arranged in TMA format. We analyzed 46 B-cell lymphoma (B-NHL) specimens with known karyotypes for translocations of IGH-, BCL2-, BCL6- and MYC-genes. Locus-specific DNA probes were used for the detection of deletions in chromosome bands 6q21 and 9p21 in 62 follicular lymphomas (FL) and six malignant mesothelioma (MM) samples, respectively. To test for aberrant signals generated by truncation of nuclei following sectioning of FFPE tissue samples, cell line dilutions with 9p21-deletions were embedded into paraffin blocks. The overall TMA hybridization efficiency was 94%. FISH results regarding translocations matched karyotyping data in 93%. As for chromosomal deletions, sectioning artefacts occurred in 17% to 25% of cells, suggesting that the proportion of cells showing deletions should exceed 25% to be reliably detectable. In conclusion, FISH represents a robust tool for the detection of structural as well as numerical aberrations in FFPE tissue samples in a TMA-based high-throughput setting, when rigorous cut-off values and appropriate controls are maintained, and, of note, was superior to quantitative PCR approaches.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] High-resolution analysis of paraffin-embedded and formalin-fixed prostate tumors using comparative genomic hybridization to genomic microarrays
    Paris, PL
    Albertson, DG
    Alers, JC
    Andaya, A
    Carroll, P
    Fridlyand, J
    Jain, AN
    Kamkar, S
    Kowbel, D
    Krijtenburg, PJ
    Pinkel, D
    Schröder, FH
    Vissers, KJ
    Watson, VJE
    Wildhagen, MF
    Collins, C
    van Dekken, H
    AMERICAN JOURNAL OF PATHOLOGY, 2003, 162 (03): : 763 - 770
  • [22] Array-Comparative Genomic Hybridization Detection of Previously Undetected Genomic Aberrations in Formalin-Fixed Paraffin-Embedded Myeloid Sarcoma
    Mirza, M. K.
    Sukhanova, M.
    Reddy, P.
    Joseph, L.
    Raca, G.
    MODERN PATHOLOGY, 2013, 26 : 498A - 498A
  • [23] Array-Comparative Genomic Hybridization Detection of Previously Undetected Genomic Aberrations in Formalin-Fixed Paraffin-Embedded Myeloid Sarcoma
    Mirza, M. K.
    Sukhanova, M.
    Reddy, P.
    Joseph, L.
    Raca, G.
    LABORATORY INVESTIGATION, 2013, 93 : 498A - 498A
  • [24] Genomic DNA extraction methods using formalin-fixed paraffin-embedded tissue
    Potluri, Keerti
    Mahas, Ahmed
    Kent, Michael N.
    Naik, Sameep
    Markey, Michael
    ANALYTICAL BIOCHEMISTRY, 2015, 486 : 17 - 23
  • [25] Multimodal analysis of formalin-fixed and paraffin-embedded tissue by MALDI imaging and fluorescence in situ hybridization for combined genetic and metabolic analysis
    Huber, Katharina
    Kunzke, Thomas
    Buck, Achim
    Langer, Rupert
    Luber, Birgit
    Feuchtinger, Annette
    Walch, Axel
    LABORATORY INVESTIGATION, 2019, 99 (10) : 1535 - 1546
  • [26] ValidatiValidation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples
    Lagheden, Camilla
    Eklund, Carina
    Kleppe, Sara Nordqvist
    Unger, Elizabeth R.
    Dillner, Joakim
    Sundstrom, Karin
    JOURNAL OF CLINICAL VIROLOGY, 2016, 80 : 36 - 39
  • [27] Molecular identification of fungi in formalin-fixed and paraffin-embedded skin tissue samples
    Futatsuya, Taketoshi
    Anzawa, Kazushi
    Mochizuki, Takashi
    Hatano, Yutaka
    JOURNAL OF DERMATOLOGY, 2019, 46 (02): : 171 - 172
  • [28] Amplification of c-erbB-2 in gastric cancer:: Detection in formalin-fixed, paraffin-embedded tissue by fluorescence in situ hybridization
    Ooi, A
    Kobayashi, M
    Mai, M
    Nakanishi, I
    LABORATORY INVESTIGATION, 1998, 78 (03) : 345 - 351
  • [29] Tissue subtraction DNA in situ hybridization (TSDISH): In situ detection of DNA abnormalities in formalin-fixed paraffin-embedded tissue sections by subtraction hybridization with whole genomic DNA
    Itakura, Y
    Sasano, H
    Mori, S
    Nagura, H
    Shimizu, S
    ANTICANCER RESEARCH, 1997, 17 (1A) : 121 - 128
  • [30] Bovine Babesiosis Diagnosed in Formalin-Fixed, Paraffin-Embedded Tissues by Using In Situ Hybridization
    Huelskoetter, Kirsten
    Pfankuche, Vanessa M.
    van Dyck, Lydia
    Hoeltershinken, Martin
    Springer, Andrea
    Lienhart, Fabienne
    Ermel, Sandra
    Rehage, Juergen
    Hoedemarker, Martina
    Strube, Christina
    Hirzmann, Joerg
    Bauer, Christian
    Baumgaertner, Wolfgang
    Lehmbecker, Annika
    Wohlsein, Peter
    VETERINARY PATHOLOGY, 2020, 57 (06) : 812 - 820