Electrospray ionization mass spectrometry and partial least squares discriminant analysis applied to the quality control of olive oil

被引:19
|
作者
Alves, Junia O. [1 ]
Botelho, Bruno G. [1 ]
Sena, Marcelo M. [1 ]
Augusti, Rodinei [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Quim, ICEx, BR-31270901 Belo Horizonte, MG, Brazil
来源
JOURNAL OF MASS SPECTROMETRY | 2013年 / 48卷 / 10期
关键词
olive oil authentication; extra virgin olive oil; ordinary olive oil; edible oils; adulteration; ESI-MS; PLS-DA; VEGETABLE-OILS; ADULTERATION; IDENTIFICATION; SPECTROSCOPY; AUTHENTICITY; PROFILES; BLENDS; ORIGIN; MS;
D O I
10.1002/jms.3256
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Direct infusion electrospray ionization mass spectrometry in the positive ion mode [ESI(+)-MS] is used to obtain fingerprints of aqueous-methanolic extracts of two types of olive oils, extra virgin (EV) and ordinary (OR), as well as of samples of EV olive oil adulterated by the addition of OR olive oil and other edible oils: corn (CO), sunflower (SF), soybean (SO) and canola (CA). The MS data is treated by the partial least squares discriminant analysis (PLS-DA) protocol aiming at discriminating the above-mentioned classes formed by the genuine olive oils, EV (1) and OR (2), as well as the EV adulterated samples, i.e. EV/SO (3), EV/CO (4), EV/SF (5), EV/CA (6) and EV/OR (7). The PLS-DA model employed is built with 190 and 70 samples for the training and test sets, respectively. For all classes (1-7), EV and OR olive oils as well as the adulterated samples (in a proportion varying from 0.5 to 20.0% w/w) are properly classified. The developed methodology required no ions identification and demonstrated to be fast, as each measurement lasted about 3 min including the extraction step and MS analysis, and reliable, because high sensitivities (rate of true positives) and specificities (rate of true negatives) were achieved. Finally, it can be envisaged that this approach has potential to be applied in quality control of EV olive oils. Copyright (C) 2013 John Wiley & Sons, Ltd. Supporting information may be found in the online version of this article.
引用
收藏
页码:1109 / 1115
页数:7
相关论文
共 50 条
  • [41] Classification of Mosquitoes with Infrared Spectroscopy and Partial Least Squares-Discriminant Analysis
    Sroute, Lamyae
    Byrd, Brian D.
    Huffman, Scott W.
    APPLIED SPECTROSCOPY, 2020, 74 (08) : 900 - 912
  • [42] libPLS: An integrated library for partial least squares regression and linear discriminant analysis
    Li, Hong-Dong
    Xu, Qing-Song
    Liang, Yi-Zeng
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 176 : 34 - 43
  • [43] Shotgun lipidomic analysis of simple lipids in rapeseed oil by electrospray ionization tandem mass spectrometry
    Xin Lv
    Fang Wei
    Shuling Xu
    Ya Xie
    Bangfu Wu
    Zongyuan Wu
    Xuyan Dong
    Hong Chen
    Oil Crop Science, 2018, 3 (04) : 247 - 257
  • [44] Partial least-squares discriminant analysis on autofluorescence spectra of oral carcinogenesis
    Wang, CY
    Chen, CT
    Chiang, CP
    Young, ST
    Chow, SN
    Chiang, HK
    APPLIED SPECTROSCOPY, 1998, 52 (09) : 1190 - 1196
  • [45] DIAGNOSIS OF DEMENTIAS USING PARTIAL LEAST-SQUARES DISCRIMINANT-ANALYSIS
    GOTTFRIES, J
    BLENNOW, K
    WALLIN, A
    GOTTFRIES, CG
    DEMENTIA, 1995, 6 (02): : 83 - 88
  • [46] Oxidation in fish-oil-enriched mayonnaise 1. Assessment of propyl gallate as an antioxidant by discriminant partial least squares regression analysis1. Assessment of propyl gallate as an antioxidant by discriminant partial least squares regression analysis
    C. Jacobsen
    Karsten Hartvigsen
    P. Lund
    Anne S. Meyer
    Jens Adler-Nissen
    Jens Holstborg
    Gunhild Hølmer
    European Food Research and Technology, 1999, 210 : 13 - 30
  • [47] Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry
    Apffel, A
    Chakel, JA
    Fischer, S
    Lichtenwalter, K
    Hancock, WS
    ANALYTICAL CHEMISTRY, 1997, 69 (07) : 1320 - 1325
  • [48] Application of electrospray ionization mass spectrometry in chiral recognition and analysis
    Liu Qin
    Zhang Shuzhen
    Wu Bidong
    Shen Rui
    Xie Jianwei
    Liu Keliang
    PROGRESS IN CHEMISTRY, 2006, 18 (06) : 780 - 788
  • [49] Intact skin analysis by desorption electrospray ionization mass spectrometry
    Katona, Maria
    Denes, Julia
    Skoumal, Reka
    Toth, Miklos
    Takats, Zoltan
    ANALYST, 2011, 136 (04) : 835 - 840
  • [50] Identification and analysis of polypeptides by electrospray ionization tandem mass spectrometry
    Bai, JF
    Liu, ZQ
    Liu, N
    Liu, SY
    Ji, ZJ
    Sheng, SL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (05) : 661 - 664