Determination of lead concentrations and isotope ratios in recent snow samples from high alpine sites with a double focusing ICP-MS

被引:34
|
作者
Doring, T
Schwikowski, M
Gaggeler, HW
机构
[1] PAUL SCHERRER INST,CH-5232 VILLIGEN,SWITZERLAND
[2] UNIV BERN,DEPT CHEM & BIOCHEM,CH-3012 BERN,SWITZERLAND
来源
关键词
D O I
10.1007/s002160050592
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A double focusing ICP-MS, equipped with a Micro Concentric Nebulizer, has been used to determine concentrations and isotopic ratios of lead in recent snow samples (1993-1996) from high alpine sites in Switzerland. Concentrations varied between 0.02 +/- 0.002 and 5.5 +/- 0.15 ng/g and are slightly lower than concentrations reported by Atteia [1], by Batifol et al. [2], and by Wagenbach et al, [3] for precipitation samples from similar remote sites in Europe. Since concentrations of lead in the fresh snow samples were mainly in the lower pg/g range, the method to determine the isotopic ratios Pb-207/Pb-206 and Pb-208/Pb-206 had to be optimized. They could finally be determined with an average standard error of 0.14% within 12 min and a total sample consumption of 0.8 mt. The average ratios Pb-207/Pb-206 and Pb-208/Pb-206 were 0.875 and 2.117, respectively. These values are comparable to isotopic compositions of lead in aerosols collected in Western Europe [4] and are less radiogenic than predicted by Grousset et al. [5]. Our data indicate that, although lead emissions from traffic have decreased largely during the last 10 years, the contribution from this source in modem snow is still detectable and seems to be equal to the lead input from other anthropogenic sources (e.g. waste incineration, industry).
引用
收藏
页码:382 / 384
页数:3
相关论文
共 50 条
  • [31] DETERMINATION OF STABLE ISOTOPE RATIO OF LEAD IN AIRBORNE PARTICULATE MATTER BY ICP-MS
    MUKAI, H
    AMBE, Y
    BUNSEKI KAGAKU, 1990, 39 (03) : 177 - 182
  • [32] Determination of lead isotope ratios in crude oils with Q-ICP/MS
    Dreyfus, S.
    Pecheyran, C.
    Lienemann, C. P.
    Magnier, C.
    Prinzhofer, A.
    Donard, O. F. X.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (04) : 351 - 360
  • [33] Recent applications on isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles
    Becker, J. Sabine
    Sela, Hagit
    Dobrowolska, Justina
    Zoriy, Miroslav
    Becker, J. Susanne
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 270 (1-2) : 1 - 7
  • [34] Application of double focusing magnetic sector high resolution ICP-MS to the study of iron stable isotope trace
    Jin, XD
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (02) : 220 - 222
  • [35] Determination of Pb isotope ratios using multiple collector ICP-MS and Tl normalization
    He, XX
    Zhu, XK
    Yang, C
    Tang, SH
    Chai, JJ
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A541 - A541
  • [36] Accurate determination of iron, copper and zinc in human serum by isotope dilution analysis using double focusing ICP-MS
    Muñiz, CS
    Gayón, JMM
    Alonso, JIG
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1505 - 1510
  • [37] Optimising ICP-MS for the determination of trace metals in high matrix samples
    McCurdy, E.
    Potter, D.
    Spectroscopy Europe, 2001, 13 (03): : 16 - 20
  • [38] Precise Determination of Isotope Ratios in Nuclear Samples by CE-MC-ICP-MS
    Dupuis, Erwan
    Isnard, Helene
    Chartier, Frederic
    30TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2021), 2021,
  • [39] Total determination of essential and toxic elements in milk whey by double focusing ICP-MS
    Martino, FAR
    Sánchez, MLF
    Medel, AS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (02) : 163 - 168
  • [40] A comparison of double-focusing sector field ICP-MS, ICP-OES and octopole collision cell ICP-MS for the high-accuracy determination of calcium in human serum