Prevalence of Esophageal Ulceration After Atrial Fibrillation Ablation with the Hot Balloon Ablation Catheter: What is the Value of Esophageal Cooling?

被引:55
|
作者
Sohara, Hiroshi [1 ]
Satake, Shutaro [1 ]
Takeda, Hiroshi [1 ]
Yamaguchi, Yoshio [1 ]
Nagasu, Naoko [2 ]
机构
[1] Shonan Kamakura Gen Hosp, Hayama Heart Ctr, Heart Rhythm Ctr, Okamoto, Kanagawa, Japan
[2] Shonan Kamakura Gen Hosp, Gastroenterol Med Ctr, Okamoto, Kanagawa, Japan
关键词
atrial fibrillation; catheter ablation; esophageal cooling; radiofrequency hot balloon; RADIOFREQUENCY ABLATION; TEMPERATURE; INJURY; FISTULA; RISK;
D O I
10.1111/jce.12394
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Esophageal Cooling During Hot Balloon Ablation. Background: Little is known about luminal esophageal temperature (LET) monitoring during catheter ablation for atrial fibrillation (AF) using the radiofrequency hot balloon (RHB) technology. Objective: The aim of this study is to investigate the impact of the use of a unique esophageal cooling method during RHB ablation. Methods and Results: In this observational study, 318 consecutive patients (231 men; mean age, 63 +/- 9 years) with symptomatic, drug-refractory, paroxysmal (n = 183) or persistent (n = 135) AF underwent RHB ablation with LET monitoring followed by a postprocedural, nonsymptom-driven esophageal endoscopy within 3 days of the ablation procedure. The patients have been divided into 3 groups. The first 22 patients treated are in Group A (n = 22) and had only LET monitoring without cooling of the esophagus. In Groups B (n = 128) and C (n = 168), patients had LET monitoring with cooling of the esophagus when the LET exceeded 43 degrees C and 39 degrees C, by infusion of cooled saline mixed with Gastrographin or Iopamidol, respectively. Group A had a higher risk of esophageal ulceration among the 3 groups (P < 0.0001). Saline infusion cooling initiated when the LET exceeded 43 degrees C (Group B) was not as safe as saline infusion cooling initiated when the LET exceeded 39 degrees C (Group C), demonstrated by the Group C minimum ulceration score and LET measurements while ablating the left superior pulmonary vein (LSPV) and left inferior pulmonary vein (LIPV) (P < 0.0001). Conclusion: Cooling the esophagus by a mix of Iopamidol and saline infusion when the LET exceeds 39 degrees C during RHB ablation may decrease the incidence and severity of esophageal thermal injury.
引用
收藏
页码:686 / 692
页数:7
相关论文
共 50 条
  • [41] Fecal calprotectin: A novel predictor of ulcerated esophageal injury after atrial fibrillation catheter ablation
    Wang, Yun-He
    Tang, Xiao-Mei
    Jiang, Ru-Hong
    Sun, Ya-Xun
    Liu, Qiang
    Zhang, Pei
    Yu, Lu
    Lin, Jian-Wei
    Cheng, Hui
    Chen, Shi-Quan
    Zhang, Zu-Wen
    Sheng, Xia
    Lin, Ne
    Chen, Xiao-Li
    Fu, Guo-Sheng
    Jiang, Chen-Yang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (01): : 167 - 171
  • [42] Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation
    Scanavacca, MI
    Avila, AD
    Parga, J
    Sosa, E
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (08) : 960 - 962
  • [43] Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation Using a Cryoballoon, Hot Balloon, or Laser Balloon
    Tokuda, Michifumi
    Yamashita, Seigo
    Shiomi, Satoko
    Sakurai, Ryutaro
    Sato, Hidenori
    Oseto, Hirotsuna
    Yokoyama, Masaaki
    Tokutake, Kenichi
    Kato, Mika
    Narui, Ryohsuke
    Tanigawa, Shin-ichi
    Yoshimura, Michihiro
    Yamane, Teiichi
    CIRCULATION JOURNAL, 2023, 87 (12) : 1711 - +
  • [44] Atrial-esophageal fingerprinting for atrial fibrillation ablation
    Ikram U. Haq
    Jackson J. Liang
    Christopher V. DeSimone
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 593 - 594
  • [45] Relevance of esophageal anatomy for ablation of atrial fibrillation
    Munger, TM
    Ryan, SL
    Njus, JM
    Friedman, PA
    Peterson, LA
    Monahan, KH
    Packer, DL
    CIRCULATION, 2004, 110 (17) : 417 - 417
  • [46] Strategies to Minimize the Risk of Esophageal Injury durings Catheter Ablation for Atrial Fibrillation
    Bahnson, Tristram D.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (02): : 248 - 260
  • [47] Esophageal deviation using a novel balloon retractor system to reduce thermal trauma in atrial fibrillation catheter ablation
    Bhardwaj, Rahul
    Naniwadekar, Aditi
    Joshi, Kamal
    Koruth, Jacob
    Whang, William
    Dukkipati, Srinivas
    Sofi, Aamir
    Miller, Marc
    Choudry, Subbarao
    Langan, Marie
    Reddy, Vivek
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (04) : 666 - 667
  • [48] A Comparative Analysis of Esophageal Cooling for Preventing Esophageal Injury Post Atrial Fibrillation Catheter Ablation: A Systematic Review and Meta-analysis
    Ibrahim, Momen Mohamed
    Al Hennawi, Hussam
    Tanas, Yousef
    Abourady, Youmna
    Sewedan, Nourhan
    Hashem, Ahmed Magdy
    Motawea, Karam R.
    CIRCULATION, 2024, 150
  • [49] The Effectiveness and Safety of the Esophageal Temperature Monitoring During Catheter Ablation of Atrial Fibrillation
    Ito, Miwa
    Kanazawa, Hisanori
    Hoshiyama, Tadashi
    Kawahara, Yusei
    Tsujita, Kenichi
    CIRCULATION, 2020, 142
  • [50] Risk of esophageal thermal injury during catheter ablation for atrial fibrillation guided by different ablation index
    Zhang, Zu-Wen
    Zhang, Pei
    Jiang, Ru-Hong
    Liu, Qiang
    Sun, Ya-Xun
    Yu, Lu
    Lin, Jian-Wei
    Chen, Shi-Quan
    Sheng, Xia
    Fu, Guo-Sheng
    Jiang, Chen-Yang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (07): : 633 - 639