Potential of attenuated total reflection infrared and near-infrared spectroscopic imaging for quality assurance/quality control of solid pharmaceutical dosage forms

被引:0
|
作者
Reich, G [1 ]
机构
[1] Heidelberg Univ, Inst Pharmaceut Technol & Biopharmaceut, D-69120 Heidelberg, Germany
来源
PHARMAZEUTISCHE INDUSTRIE | 2002年 / 64卷 / 8A期
关键词
attenuated total reflection; Fourier transform infrared spectroscopy; drug distribution; film coat uniformity; near-infrared spectroscopy; solid dosage forms; spectroscopic imaging;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Methods that can spatially characterise the distribution of components throughout solid pharmaceutical dosage forms are of great interest to ensure product quality and enhance production speed. Infrared (IR) spectroscopy in combination with traditional microscopy has been available for more than a quarter of a century. Until recently, a very time-consuming step-by-step "mapping" procedure was necessary to determine large sample areas. This drawback considerably limited the use of this technique for many applications. With the development of novel imaging systems based on Focal Plane Array (FPA) detector technology, which enable large areas to be measured simultaneously with a high local resolution, it is now possible to rapidly collect high contrast images of large sample areas. The state of the art in Attenuated Total Reflection (ATR)-IR and Near-Infrared (NIR) imaging techniques is reviewed and discussed indicating that only few pharmaceutical applications have been reported in the literature. This work suggests that both ATR-IR and NIR imaging have considerable value for the chemical and functional characterisation of complex solid pharmaceutical dosage forms. Two novel applications are presented in detail: 1. Chemical visualisation of variations in film coat uniformity on tablets. 2. Chemical mapping of the distribution and relative abundance of a model protein in polymer matrix tablets, immediately after processing and during the release phase. It is demonstrated that both techniques provide rapid information about the type, distribution and relative abundance of drugs and/or excipients within a solid pharmaceutical dosage form, thus having great potential for a variety of pharmaceutical Quality Assurance/Quality Control applications.
引用
收藏
页码:870 / 874
页数:7
相关论文
共 50 条
  • [41] Investigation of applicability of a mid-infrared spectroscopic method using an attenuated total reflection accessory and a new near-infrared transmission method for determination of faecal fat
    Volmer, M
    Kingma, AW
    Borsboom, PCF
    Wolthers, BG
    Kema, IP
    ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 : 256 - 263
  • [42] Comparison of near-infrared and laser-induced breakdown spectroscopy for determination of magnesium stearate in pharmaceutical powders and solid dosage forms
    Green, RL
    Mowery, MD
    Good, JA
    Higgins, JP
    Arrivo, SM
    McColough, K
    Mateos, A
    Reed, RA
    APPLIED SPECTROSCOPY, 2005, 59 (03) : 340 - 347
  • [43] QUALITY-CONTROL IN MANUFACTURING PROCESS BY NEAR-INFRARED SPECTROSCOPY
    GONZALEZ, F
    POUS, R
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (4-5) : 419 - 423
  • [44] FLOUR QUALITY-CONTROL BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    THOMPSON, BN
    WILLIAMS, PC
    MCLAY, GW
    KENT, W
    WETZEL, D
    CEREAL FOODS WORLD, 1979, 24 (09) : 460 - 460
  • [45] NEAR-INFRARED INSTRUMENTS IN FLOUR MILL QUALITY-CONTROL
    WILLIAMS, PC
    THOMPSON, BN
    WETZEL, D
    MCLAY, GW
    LOEWEN, D
    CEREAL FOODS WORLD, 1981, 26 (05) : 234 - 237
  • [46] Cannabidiol oil quality control with near-infrared spectroscopy.
    Ghosh, Supratim
    Hopkins, Adam
    Hagemann, Elena
    Agerer, Andreas
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2021, 98 : 75 - 76
  • [47] Two-dimensional attenuated total reflection infrared and near-infrared correlation study of the structure of butyl alcohol/water mixtures
    Wojtkow, Dagmara
    Czarnecki, Miroslaw A.
    APPLIED SPECTROSCOPY, 2007, 61 (09) : 928 - 934
  • [48] Quality Control of Valerianae Radix by Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) Spectroscopy
    Nikzad-Langerodi, Ramin
    Arth, Katharina
    Klatte-Asselmeyer, Valerie
    Bressler, Sabine
    Saukel, Johannes
    Reznicek, Gottfried
    Dobes, Christoph
    PLANTA MEDICA, 2018, 84 (6-7) : 442 - 448
  • [49] Quality control of multi-component, intact pharmaceutical tablets with three different near-infrared apparatuses
    Cournoyer, A.
    Simard, J. -S.
    Cartilier, L.
    Abatzoglou, N.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2008, 13 (05) : 333 - 343
  • [50] Potential of Near-Infrared (NIR) Spectroscopy and Hyperspectral Imaging for Quality and Safety Assessment of Fruits: an Overview
    Chandrasekaran, Indurani
    Panigrahi, Shubham Subrot
    Ravikanth, Lankapalli
    Singh, Chandra B.
    FOOD ANALYTICAL METHODS, 2019, 12 (11) : 2438 - 2458