STRAIN-DEPENDENT MODULATION OF ULTRASOUND SPEED IN ARTICULAR CARTILAGE UNDER DYNAMIC COMPRESSION

被引:10
|
作者
Lotjonen, Pauno [1 ]
Julkunen, Petro [2 ]
Toyras, Juha [1 ,2 ]
Lammi, Mikko J. [3 ,4 ]
Jurvelin, Jukka S. [1 ,5 ]
Nieminen, Heikki J. [1 ]
机构
[1] Univ Kuopio, Dept Phys, FI-70211 Kuopio, Finland
[2] Kuopio Univ Hosp, Dept Clin Neurophysiol, SF-70210 Kuopio, Finland
[3] Univ Kuopio, Inst Biomed, FI-70211 Kuopio, Finland
[4] Univ Kuopio, Dept Biosci Appl Biotechnol & Bioctr Kuopio, FI-70211 Kuopio, Finland
[5] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, SF-70210 Kuopio, Finland
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2009年 / 35卷 / 07期
关键词
Articular cartilage; Osteoarthrosis; Elastography; Mechanical indentation; Ultrasound speed; Collagen; Void ratio; Finite element modeling; POLARIZED-LIGHT MICROSCOPY; REINFORCED FINITE-ELEMENT; IN-VITRO; COLLAGEN NETWORK; SOFT-TISSUES; 100; MHZ; ELASTOGRAPHY; DEGENERATION; ELASTICITY; ANISOTROPY;
D O I
10.1016/j.ultrasmedbio.2009.03.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Mechanical properties of articular cartilage may be determined by means of mechano-acoustic indentation, a clinically feasible technique for cartilage diagnostics. Unfortunately, ultrasound speed varies in articular cartilage during mechanical compression. This can cause significant errors to the measured mechanical parameters. In this study, the strain-dependent variation in ultrasound speed was investigated during dynamic compression. In addition, we estimated errors that were induced by the variation in ultrasound speed on the mechano-acoustically measured elastic properties of the tissue. Further, we validated a computational method to correct these errors. Bovine patellar cartilage samples (n = 7) were tested under unconfined compression. Strain-dependence of ultrasound speed was determined under different compressive strains using an identical strain-rate. In addition, the modulation of ultrasound speed was simulated using the transient compositional and structural changes derived from fibril-reinforced poroviscoelastic (FRPVE) model. Experimentally, instantaneous compressive strain modulated the ultrasound speed (p < 0.05) significantly. The decrease of ultrasound speed was found to change nonlinearly as a function of strain. Immediately after the ramp loading ultrasound speed was found to be changed -0.94%, -1.49%, -1.84%, -1.87%, -1.89% and -2.15% at the strains of 2.4%, 4.9%, 7.3%, 9.7%, 12.1% and 14.4%, respectively. The numerical simulation revealed that the compression-related decrease in ultrasound speed induces significant errors in the mechano-acoustically determined strain (39.7%) and dynamic modulus (72.1%) at small strains, e.g., at 2.4%. However, at higher strains, e.g., at 14.4%, the errors were smaller, i.e., 12.6% for strain and 14.5% for modulus. After the proposed computational correction, errors related to ultrasound speed were decreased. By using the correction, with e.g., 2.4% strain, errors in strain and modulus were decreased from 39.7% to 7.2% and from 72.1% to 35.3%, respectively. The FRPVE model, addressing the changes in fibril orientation and void ratio during compression, showed discrepancy of less than 1% between the predicted and measured ultrasound speed during the ramp compression. (E-mail:juha.toyras@kuh.fi) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1177 / 1184
页数:8
相关论文
共 50 条
  • [21] A compression system for studying depth-dependent mechanical properties of articular cartilage under dynamic loading conditions
    Komeili, Amin
    Abusara, Ziad
    Federico, Salvatore
    Herzog, Walter
    MEDICAL ENGINEERING & PHYSICS, 2018, 60 : 103 - 108
  • [22] STRAIN-DEPENDENT MODULATION OF MEMORY BY STRESS IN MICE
    CASTELLANO, C
    PUGLISIALLEGRA, S
    BEHAVIORAL AND NEURAL BIOLOGY, 1983, 38 (01): : 133 - 138
  • [23] Imaging articular cartilage under compression-cartilage elastography
    Hardy, PA
    Ridler, AC
    Chiarot, CB
    Plewes, DB
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1065 - 1073
  • [24] Strain distribution of repaired articular cartilage defects by tissue engineering under compression loading
    Shilei Wang
    Yan Bao
    Yinjie Guan
    Chunqiu Zhang
    Haiying Liu
    Xu Yang
    Lilan Gao
    Tongtong Guo
    Qian Chen
    Journal of Orthopaedic Surgery and Research, 13
  • [25] Strain distribution of repaired articular cartilage defects by tissue engineering under compression loading
    Wang, Shilei
    Bao, Yan
    Guan, Yinjie
    Zhang, Chunqiu
    Liu, Haiying
    Yang, Xu
    Gao, Lilan
    Guo, Tongtong
    Chen, Qian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [26] Measurement of ultrasound speed of articular cartilage in variable conditions
    Patil, SG
    Zheng, YP
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1341 - 1344
  • [27] Strain-dependent viscoelastic behaviour and rupture force of single chondrocytes and chondrons under compression
    Bac V. Nguyen
    Qiguang Wang
    Nicola J. Kuiper
    Alicia J. El Haj
    Colin R. Thomas
    Zhibing Zhang
    Biotechnology Letters, 2009, 31 : 803 - 809
  • [28] Strain-dependent viscoelastic behaviour and rupture force of single chondrocytes and chondrons under compression
    Nguyen, Bac V.
    Wang, Qiguang
    Kuiper, Nicola J.
    El Haj, Alicia J.
    Thomas, Colin R.
    Zhang, Zhibing
    BIOTECHNOLOGY LETTERS, 2009, 31 (06) : 803 - 809
  • [29] Ultrasonic measurement of depth-dependent transient behaviors of articular cartilage under compression
    Zheng, YP
    Niu, HJ
    Mak, FTA
    Huang, YP
    JOURNAL OF BIOMECHANICS, 2005, 38 (09) : 1830 - 1837
  • [30] Strain-dependent modulation of macrophage polarization within scaffolds
    Ballotta, Virginia
    Driessen-Mol, Anita
    Bouten, Carlijn V. C.
    Baaijens, Frank P. T.
    BIOMATERIALS, 2014, 35 (18) : 4919 - 4928