Comparative Safety of Vascular Closure Devices and Manual Closure Among Patients Having Percutaneous Coronary Intervention

被引:24
|
作者
Gurm, Hitinder S.
Hosman, Carrie
Share, David
Moscucci, Mauro
Hansen, Ben B.
机构
[1] Univ Michigan, Med Ctr, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ann Arbor, MI 48109 USA
[3] Blue Cross & Blue Shield Michigan, Detroit, MI USA
[4] Univ Miami, Miami, FL USA
基金
美国国家科学基金会;
关键词
CARDIAC-CATHETERIZATION; COMPLICATIONS; METAANALYSIS; RISK; ASSOCIATION; COMPRESSION; ANGIOGRAPHY; MANAGEMENT; MORTALITY; SELECTION;
D O I
10.7326/0003-4819-159-10-201311190-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of vascular closure devices (VCDs) in patients having percutaneous coronary intervention (PCI) is controversial, and recommendations for use vary. Objective: To examine the use of and outcomes associated with VCDs in real-world practice. Design: Observational cohort study. Setting: 32 hospitals in Michigan that participate in a large multicenter quality improvement collaborative. Patients: Consecutive patients having emergent and nonemergent PCI from 2007 to 2009. Measurements: Vascular complications and the need for transfusion. Results: Of the 85 048 PCIs performed during the study that met the inclusion criteria, 28 528 (37%) procedures used VCDs. In propensity score-matched analysis, VCDs were associated with reductions in vascular complications (odds ratio [OR], 0.78 [95% CI, 0.67 to 0.90]; P = 0.001) and postprocedure transfusions (OR, 0.85 [CI, 0.74 to 0.96]; P = 0.011). These findings were consistent across many prespecified subgroups except for patients with a body mass index (BMI) less than 25 kg/m(2) and those treated with platelet glycoprotein (GP) IIb/IIIa inhibitors, in whom the benefit of VCDs over manual closure was attenuated. When the specific subtypes of vascular complications were evaluated, VCDs were associated with fewer hematomas (OR, 0.69 [CI, 0.58 to 0.83]; P < 0.001) or pseudoaneurysms (OR, 0.54 [CI, 0.38 to 0.76]; P < 0.001) but an increase in the odds of retroperitoneal bleeding (OR, 1.57 [CI, 1.12 to 2.20]; P = 0.009). Limitation: Unmeasured confounding cannot be excluded despite the study having measured and balanced many confounders. Conclusion: Vascular closure devices were associated with a significant reduction in vascular complications and need for transfusion in this large cohort of patients having transfemoral PCI. This benefit was lost in patients receiving GP IIb/IIIa inhibitors and those with normal or lean BMI and was counterbalanced by a small increase in the more serious risk for retroperitoneal bleeding.
引用
收藏
页码:660 / +
页数:10
相关论文
共 50 条
  • [31] Early experience with the Prostar(TM) percutaneous vascular closure device in patients following coronary intervention
    Calver, AJ
    Radvan, J
    Dawkins, KD
    Gray, HH
    Morgan, JM
    Simpson, IA
    HEART, 1996, 75 (05) : 96 - 96
  • [32] Infectious complications of percutaneous vascular closure devices
    Sohail, MR
    Khan, AH
    Holmes, DR
    Wilson, WR
    Steckelberg, JM
    Baddour, LM
    MAYO CLINIC PROCEEDINGS, 2005, 80 (08) : 1011 - 1015
  • [33] Vascular Complications after Percutaneous Coronary Intervention Following Hemostasis with the Mynx Vascular Closure Device Versus the AngioSeal Vascular Closure Device
    Azmoon, Shah
    Pucillo, Anthony L.
    Aronow, Wilbert S.
    Ebrahimi, Ramin
    Vozzolo, Joseph
    Rajdev, Archana
    Kalapatapu, Kumar
    Ro, Jae H.
    Hjemdahl-Monsen, Craig
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (04): : 175 - 178
  • [34] VASCULAR COMPLICATIONS AFTER PERCUTANEOUS CORONARY INTERVENTION FOLLOWING HEMOSTASIS WITH THE MYNX VASCULAR CLOSURE DEVICE VERSUS THE ANGIOSEAL VASCULAR CLOSURE DEVICE
    Azmoon, S.
    Aronow, W. S.
    Vozzolo, J.
    Rajdev, A.
    Kalapatapu, K.
    Pucillo, A. L.
    Monsen, C. E.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (04) : 613 - 614
  • [35] Femoral puncture closure devices versus manual compression after percutaneous coronary interventions
    Doneux, P
    Gach, O
    Martinez, CH
    Legrand, V
    EUROPEAN HEART JOURNAL, 2001, 22 : 216 - 216
  • [36] VASCULAR COMPLICATIONS WITH THE USE OF CLOSURE DEVICES COMPARED TO MANUAL COMPRESSION AFTER PERCUTANEOUS CORONARY INTERVENTIONS: EVALUATION WITH DUPLEX ULTRASONOGRAPHY
    Cerne, A.
    Noc, M.
    ATHEROSCLEROSIS SUPPLEMENTS, 2008, 9 (01) : 155 - 155
  • [37] Practices and Complications of Vascular Closure Devices and Manual Compression in Patients Undergoing Elective Transfemoral Coronary Procedures
    Smilowitz, Nathaniel R.
    Kirtane, Ajay J.
    Guiry, Michael
    Gray, William A.
    Dolcimascolo, Pilar
    Querijero, Michael
    Echeverry, Claudia
    Kalcheva, Nellie
    Flores, Braulio
    Singh, Varinder P.
    Rabbani, LeRoy
    Kodali, Susheel
    Collins, Michael B.
    Leon, Martin B.
    Moses, Jeffrey W.
    Weisz, Giora
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (02): : 177 - 182
  • [38] Femoral vascular access complications following arteriotomy closure devices: A comparison with manual compression after percutaneous coronary interventions
    Mehran, R
    Dangas, G
    Hong, MK
    Deible, R
    Faraj, H
    El Sayyad, S
    Negoita, M
    Okubagzi, P
    Astatkie, M
    Pichard, AD
    Stone, GW
    Leon, MB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 33A - 34A
  • [39] Vascular complications and arteriotomy closure devices during percutaneous coronary procedures - Reply
    Dangas, GD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) : 2096 - 2096
  • [40] Femoral access management: comparison between two different vascular closure devices after percutaneous coronary intervention
    Legrand, V
    Doneux, P
    Martinez, C
    Gach, O
    Bellekens, M