Development and Validation of the University of Washington Clinical Assessment of Music Perception Test

被引:131
|
作者
Kang, Robert [1 ,2 ]
Nimmons, Grace Liu [3 ]
Drennan, Ward [1 ]
Longnion, Jeff [1 ]
Ruffin, Chad [1 ,4 ]
Nie, Kaibao [1 ,2 ]
Won, Jong Ho [1 ,5 ]
Worman, Tina [2 ]
Yueh, Bevan [6 ]
Rubinstein, Jay [1 ,2 ,5 ]
机构
[1] Univ Washington, Virginia Merrill Bloedel Hearing Res Ctr, Seattle, WA 98195 USA
[2] Univ Washington, Dept Otolaryngol Head & Neck Surg, Seattle, WA 98195 USA
[3] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[4] Louisiana State Univ, Sch Med, Shreveport, LA USA
[5] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[6] Univ Minneapolis, Dept Otolaryngol Head & Neck Surg, Minneapolis, MN USA
来源
EAR AND HEARING | 2009年 / 30卷 / 04期
关键词
COCHLEAR IMPLANT RECIPIENTS; SPEECH RECEPTION; HEARING ADULTS; PITCH; NOISE; RECOGNITION; USERS; LISTENERS;
D O I
10.1097/AUD.0b013e3181a61bc0
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Assessment of cochlear implant outcomes centers around speech discrimination. Despite dramatic improvements in speech perception, music perception remains a challenge for most cochlear implant users. No standardized test exists to quantify music perception in a clinically practical manner. This study presents the University of Washington Clinical Assessment of Music Perception (CAMP) test as a reliable and valid music perception test for English-speaking, adult cochlear implant users. Design: Forty-two cochlear implant subjects were recruited from the University of Washington Medical Center cochlear implant program and referred by two implant manufacturers. Ten normal-hearing volunteers were drawn from the University of Washington Medical Center and associated campuses. A computer-driven, self-administered test was developed to examine three specific aspects of music perception: pitch direction discrimination, melody recognition, and timbre recognition. The pitch subtest used an adaptive procedure to determine just-noticeable differences for complex tone pitch direction discrimination within the range of 1 to 12 semitones. The melody and timbre subtests assessed recognition of 12 commonly known melodies played with complex tones in an isochronous manner and eight musical instruments playing an identical five-note sequence, respectively. Testing was repeated for cochlear implant subjects to evaluate test-retest reliability. Normal-hearing volunteers were also tested to demonstrate differences in performance in the two populations. Results: For cochlear implant subjects, pitch direction discrimination just-noticeable differences ranged from 1 to 8.0 semitones (Mean = 3.0, SD = 2.3). Melody and timbre recognition ranged from 0 to 94.4% correct (mean = 25.1, SD = 22.2) and 20.8 to 87.5% (mean = 45.3, SD = 16.2), respectively. Each subtest significantly correlated at least moderately with both Consonant-Nucleus-Consonant (CNC) word recognition scores and spondee recognition thresholds in steady state noise and two-talker babble. Intraclass coefficients demonstrating test-retest correlations for pitch, melody, and timbre were 0.85, 0.92, and 0.69, respectively. Normal-hearing volunteers had a mean pitch direction discrimination threshold of 1.0 semitone, the smallest interval tested, and mean melody and timbre recognition scores of 87.5 and 94.2%, respectively. Conclusions: The CAMP test discriminates a wide range of music perceptual ability in cochlear implant users. Moderate correlations were seen between music test results and both Consonant-Nucleus-Consonant word recognition scores and spondee recognition thresholds in background noise. Test-retest reliability was moderate to strong. The CAMP test provides a reliable and valid metric for a clinically practical, standardized evaluation of music perception in adult cochlear implant users.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 50 条
  • [41] The Washington University Institute for Clinical and Translational Sciences
    Evanoff, Bradley
    Cottler, Linda
    Nagarajan, Rakesh
    Garbutt, Jane
    Polonsky, Kenneth
    CTS-CLINICAL AND TRANSLATIONAL SCIENCE, 2009, 2 (05): : 322 - 324
  • [42] DEVELOPMENT AND VALIDATION OF A TEST-SPECIFIC PERCEPTION QUESTIONNAIRE FOR THE ASSESSMENT OF CARBOHYDRATE INDUCED GASTROINTESTINAL SYMPTOMS: THE ADULT CARBOCEPTION QUESTIONNAIRE (ACCQ)
    Hammer, Johann
    Hammer, Heinz
    Sonyi, Marc
    Vogelsang, Harald
    GASTROENTEROLOGY, 2019, 156 (06) : S313 - S314
  • [43] Development and validation of the Social Anxiety Test in university students (SAT-U)
    Moran, Valeria E.
    Olaz, Fabian O.
    Perez, Edgardo R.
    del Prette, Zilda A. P.
    LIBERABIT-REVISTA DE PSICOLOGIA, 2018, 24 (02): : 195 - 212
  • [44] Reliability of the Washington University road test - A performance-based assessment for drivers with dementia of the Alzheimer type
    Hunt, LA
    Murphy, CF
    Carr, D
    Duchek, JM
    Buckles, V
    Morris, JC
    ARCHIVES OF NEUROLOGY, 1997, 54 (06) : 707 - 712
  • [45] University of Washington Center on Human Development and Disability
    Guralnick, MJ
    INTERNATIONAL JOURNAL OF DEVELOPMENTAL NEUROSCIENCE, 2002, 20 (3-5) : 469 - 469
  • [46] INTERNATIONAL DEVELOPMENT TECHNOLOGY CENTER OF WASHINGTON UNIVERSITY
    MORGAN, RP
    ENGINEERING EDUCATION, 1969, 60 (01): : 60 - &
  • [47] The Development of A Survey Instrument: Assessing University Students' Perception On The Quality of Classroom Assessment
    Faridah
    Arismunandar
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON EDUCATION, SCIENCE, AND TECHNOLOGY (ICEST 2017), 2017, 149 : 142 - 145
  • [48] ON 2 APPROACHES TO DEVELOPMENT OF MUSIC PERCEPTION
    TARASSOV, GS
    PSIKHOLOGICHESKII ZHURNAL, 1994, 15 (06) : 130 - 132
  • [49] VALIDATION OF A CLINICAL ANTISACCADIC EYE-MOVEMENT TEST IN THE ASSESSMENT OF DEMENTIA
    CURRIE, J
    RAMSDEN, B
    MCARTHUR, C
    MARUFF, P
    ARCHIVES OF NEUROLOGY, 1991, 48 (06) : 644 - 648
  • [50] Clinical Test for Validation of a New Optical Probe for Hemodynamic Parameters Assessment
    Pereira, T.
    Santos, I.
    Oliveira, T.
    Vaz, P.
    Santos Pereira, T.
    Santos, H.
    Almeida, V.
    Pereira, H. C.
    Correia, C.
    Cardoso, J.
    BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES (BIOSTEC 2013), 2014, 452 : 269 - 283