Development and Validation of the University of Washington Clinical Assessment of Music Perception Test

被引:131
|
作者
Kang, Robert [1 ,2 ]
Nimmons, Grace Liu [3 ]
Drennan, Ward [1 ]
Longnion, Jeff [1 ]
Ruffin, Chad [1 ,4 ]
Nie, Kaibao [1 ,2 ]
Won, Jong Ho [1 ,5 ]
Worman, Tina [2 ]
Yueh, Bevan [6 ]
Rubinstein, Jay [1 ,2 ,5 ]
机构
[1] Univ Washington, Virginia Merrill Bloedel Hearing Res Ctr, Seattle, WA 98195 USA
[2] Univ Washington, Dept Otolaryngol Head & Neck Surg, Seattle, WA 98195 USA
[3] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[4] Louisiana State Univ, Sch Med, Shreveport, LA USA
[5] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[6] Univ Minneapolis, Dept Otolaryngol Head & Neck Surg, Minneapolis, MN USA
来源
EAR AND HEARING | 2009年 / 30卷 / 04期
关键词
COCHLEAR IMPLANT RECIPIENTS; SPEECH RECEPTION; HEARING ADULTS; PITCH; NOISE; RECOGNITION; USERS; LISTENERS;
D O I
10.1097/AUD.0b013e3181a61bc0
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Assessment of cochlear implant outcomes centers around speech discrimination. Despite dramatic improvements in speech perception, music perception remains a challenge for most cochlear implant users. No standardized test exists to quantify music perception in a clinically practical manner. This study presents the University of Washington Clinical Assessment of Music Perception (CAMP) test as a reliable and valid music perception test for English-speaking, adult cochlear implant users. Design: Forty-two cochlear implant subjects were recruited from the University of Washington Medical Center cochlear implant program and referred by two implant manufacturers. Ten normal-hearing volunteers were drawn from the University of Washington Medical Center and associated campuses. A computer-driven, self-administered test was developed to examine three specific aspects of music perception: pitch direction discrimination, melody recognition, and timbre recognition. The pitch subtest used an adaptive procedure to determine just-noticeable differences for complex tone pitch direction discrimination within the range of 1 to 12 semitones. The melody and timbre subtests assessed recognition of 12 commonly known melodies played with complex tones in an isochronous manner and eight musical instruments playing an identical five-note sequence, respectively. Testing was repeated for cochlear implant subjects to evaluate test-retest reliability. Normal-hearing volunteers were also tested to demonstrate differences in performance in the two populations. Results: For cochlear implant subjects, pitch direction discrimination just-noticeable differences ranged from 1 to 8.0 semitones (Mean = 3.0, SD = 2.3). Melody and timbre recognition ranged from 0 to 94.4% correct (mean = 25.1, SD = 22.2) and 20.8 to 87.5% (mean = 45.3, SD = 16.2), respectively. Each subtest significantly correlated at least moderately with both Consonant-Nucleus-Consonant (CNC) word recognition scores and spondee recognition thresholds in steady state noise and two-talker babble. Intraclass coefficients demonstrating test-retest correlations for pitch, melody, and timbre were 0.85, 0.92, and 0.69, respectively. Normal-hearing volunteers had a mean pitch direction discrimination threshold of 1.0 semitone, the smallest interval tested, and mean melody and timbre recognition scores of 87.5 and 94.2%, respectively. Conclusions: The CAMP test discriminates a wide range of music perceptual ability in cochlear implant users. Moderate correlations were seen between music test results and both Consonant-Nucleus-Consonant word recognition scores and spondee recognition thresholds in background noise. Test-retest reliability was moderate to strong. The CAMP test provides a reliable and valid metric for a clinically practical, standardized evaluation of music perception in adult cochlear implant users.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 50 条
  • [1] Development and Validation of The Anadolu University Music Perception Test
    Tunca, Ozan Evrim
    Kumtepe, Evrim Genc
    Torun, Sukru
    Ugurhan, Yusuf Zafer Can
    INTERNATIONAL JOURNAL OF MUSIC EDUCATION, 2024, 42 (04) : 644 - 659
  • [2] Development and validation of the first adaptive test of emotion perception in music
    MacGregor, Chloe
    Ruth, Nicolas
    Muellensiefen, Daniel
    COGNITION & EMOTION, 2023, 37 (02) : 284 - 302
  • [3] Development of the Adaptive Music Perception Test
    Kirchberger, Martin J.
    Russo, Frank A.
    EAR AND HEARING, 2015, 36 (02): : 217 - 228
  • [4] Development of a clinical test of musical perception: Appreciation of music in cochlear implantees (AMICI)
    Spitzer, Jaclyn B.
    Mancuso, Dean
    Cheng, Min-Yu
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2008, 19 (01) : 56 - 81
  • [5] Development and Validation of a Competence Model in Music Instruction - Perception and contextualization of music
    Jordan, Anne-Katrin
    Knigge, Jens
    Lehmann, Andreas C.
    Niessen, Anne
    Lehmann-Wermser, Andreas
    ZEITSCHRIFT FUR PADAGOGIK, 2012, 58 (04): : 500 - 521
  • [6] Development and validation of the Mandarin speech perception test
    Fu, Qian-Jie
    Zhu, Meimei
    Wang, Xiaosong
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (06): : EL267 - EL273
  • [7] Development and Validation of the Spanish Hazard Perception Test
    Castro, C.
    Padilla, J. L.
    Roca, J.
    Benitez, I.
    Garcia-Fernandez, P.
    Estevez, B.
    Lopez-Ramon, M. F.
    Crundall, D.
    TRAFFIC INJURY PREVENTION, 2014, 15 (08) : 817 - 826
  • [8] Development and validation of the Music Cognitive Test: A music-based cognitive screening test
    Mangiacottil, Anthony
    Cipriani, Giovanna
    Ward, Emma
    Franco, Fabia
    Biasutti, Michele
    PSYCHOLOGY OF MUSIC, 2023, 51 (02) : 373 - 394
  • [9] Clinical assessment of music perception in cochlear implant listeners
    Nimmons, Grace L.
    Kang, Robert S.
    Drennan, Ward R.
    Longnion, Jeff
    Ruffin, Chad
    Worman, Tina
    Yueh, Bevan
    Rubinstein, Jay T.
    OTOLOGY & NEUROTOLOGY, 2008, 29 (02) : 149 - 155