Single channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals

被引:0
|
作者
Hennig, Wolfgang [1 ]
Tan, Hui [1 ]
Warburton, William K. [1 ]
McIntyre, Justin I. [1 ]
机构
[1] XIA LLC, Newark, CA 94560 USA
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monitoring radioactive xenon in the atmosphere is one of several methods used to detect nuclear weapons testing. To increase sensitivity, monitoring stations use a complex system of separate beta and gamma detectors to detect beta-gamma coincidences from the Xe isotopes of interest, which is effective, but requires such careful gain matching and calibration that it is difficult to operate in the field. To simplify the system, a phoswich detector has been designed, consisting of optically coupled plastic and Csl scintillators to absorb beta particles and gamma rays, respectively. Digital pulse shape analysis of the detector signal is used to determine if radiation interacted in either or both parts of the detector and to measure the energy deposited in each part, thus using only a single channel of readout electronics to detect beta-gamma coincidences and to measure both energies. Experiments with a prototype detector show that the technique can clearly separate event types, does not degrade the energy resolution, and has an error rate for detecting coincidences of less than 0.1%. Monte Carlo simulations of radiation transport and light collection in the proposed detector were performed to obtain optimum values for its design parameters and an estimate of the coincidence detection efficiency (82-92%) and the background rejection rate (better than 99%).
引用
收藏
页码:510 / 514
页数:5
相关论文
共 33 条
  • [1] Single-channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals
    Hennig, W
    Tan, H
    Warburton, WK
    McIntyre, JI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) : 620 - 624
  • [2] Modelling of a Single-Channel Beta-Gamma Coincidence Phoswich Detector Using Geant4 for the Conversion Electron Energy Peak Resolution and Beta-Gamma Coincidence Efficiency Improvement
    Zhang, Weihua
    Mekarski, Pawel
    Bean, Marc
    Yi, Jing
    Ungar, Kurt
    PURE AND APPLIED GEOPHYSICS, 2014, 171 (3-5) : 621 - 627
  • [3] Geant4 analysis and optimization of a double crystal phoswich detector for beta-gamma coincidence detection
    Fan, Xing
    Zhang, Xian-Peng
    Tian, Geng
    Yang, Chao-Wen
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (04)
  • [4] Novel beta-gamma coincidence measurements using phoswich detectors
    J. H. Ely
    C. E. Aalseth
    J. I. McIntyre
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 263 : 245 - 250
  • [5] Novel beta-gamma coincidence measurements using phoswich detectors
    Ely, JH
    Aalseth, CE
    McIntyre, JI
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (01) : 245 - 250
  • [6] An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations
    Zhang, Weihua
    Mekarski, Pawel
    Bean, Marc
    Yi, Jing
    Ungar, Kurt
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2011, 2011
  • [7] Calibration of low-level beta-gamma coincidence detector systems for xenon isotope detection
    Khrustalev, K.
    Wieslander, J. S. E.
    Auer, M.
    Gheddou, A.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 418 - 424
  • [8] Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis
    de Celis, B.
    de la Fuentea, R.
    Williart, A.
    Alonsoc, B. de Celis
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 206 - 209
  • [9] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Zhang, Weihua
    Mekarski, Pawel
    Lam, Jonathan
    Ungar, Kurt
    Pellerin, Eric
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 285 (03) : 475 - 482
  • [10] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Weihua Zhang
    Pawel Mekarski
    Jonathan Lam
    Kurt Ungar
    Eric Pellerin
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 285 : 475 - 482