Single-channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals

被引:29
|
作者
Hennig, W [1 ]
Tan, H
Warburton, WK
McIntyre, JI
机构
[1] XIA LLC, Newark, CA 94560 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
beta-gamma coincidence detection; digital pulse shape analysis; phoswich detector; radioxenon monitoring;
D O I
10.1109/TNS.2006.870447
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monitoring radioactive xenon in the atmosphere is one of several methods used to detect nuclear weapons testing. To increase sensitivity, monitoring stations use a complex system of separate beta and gamma detectors to detect beta-gamma coincidences from the Xe isotopes of interest, which is effective but requires such careful gain matching and calibration that it is difficult to operate in the field. To simplify the system, a phoswich detector has been designed, consisting of optically coupled plastic and CsI scintillators to absorb beta particles and gamma rays, respectively. Digital pulse shape analysis (PSA) of the detector signal is used to determine if radiation interacted in either or both parts of the detector and to measure the energy deposited in each part, thus using only a single channel of readout electronics to detect beta-gamma coincidences and to measure both energies. Experiments with a prototype detector show that the technique can clearly separate event types, does not degrade the energy resolution, and has an error rate for detecting coincidences of less than 0.1%. Monte Carlo simulations of radiation transport and light collection in the proposed detector were performed to obtain optimum values for its design parameters and an estimate of the coincidence detection efficiency (82%-92%) and the background rejection rate (better than 99%).
引用
收藏
页码:620 / 624
页数:5
相关论文
共 15 条
  • [1] Single channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals
    Hennig, Wolfgang
    Tan, Hui
    Warburton, William K.
    McIntyre, Justin I.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 510 - 514
  • [2] Modelling of a Single-Channel Beta-Gamma Coincidence Phoswich Detector Using Geant4 for the Conversion Electron Energy Peak Resolution and Beta-Gamma Coincidence Efficiency Improvement
    Zhang, Weihua
    Mekarski, Pawel
    Bean, Marc
    Yi, Jing
    Ungar, Kurt
    PURE AND APPLIED GEOPHYSICS, 2014, 171 (3-5) : 621 - 627
  • [3] An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations
    Zhang, Weihua
    Mekarski, Pawel
    Bean, Marc
    Yi, Jing
    Ungar, Kurt
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2011, 2011
  • [4] Geant4 analysis and optimization of a double crystal phoswich detector for beta-gamma coincidence detection
    Fan, Xing
    Zhang, Xian-Peng
    Tian, Geng
    Yang, Chao-Wen
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (04)
  • [5] Modelling of a Single-Channel Beta–Gamma Coincidence Phoswich Detector Using Geant4 for the Conversion Electron Energy Peak Resolution and Beta–Gamma Coincidence Efficiency Improvement
    Weihua Zhang
    Pawel Mekarski
    Marc Bean
    Jing Yi
    Kurt Ungar
    Pure and Applied Geophysics, 2014, 171 : 621 - 627
  • [6] Calibration of low-level beta-gamma coincidence detector systems for xenon isotope detection
    Khrustalev, K.
    Wieslander, J. S. E.
    Auer, M.
    Gheddou, A.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 418 - 424
  • [7] Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis
    de Celis, B.
    de la Fuentea, R.
    Williart, A.
    Alonsoc, B. de Celis
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 206 - 209
  • [8] A triple-crystal phoswich detector with digital pulse shape discrimination for alpha/beta/gamma spectroscopy
    White, TL
    Miller, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 144 - 147
  • [9] A multi-channel beta-gamma coincidence counting system using well-HPGe and plastic scintillation detectors for radioactive Xenon measurements
    Byun, Jong-In
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 949 (949):
  • [10] Geant4 analysis and optimization of a double crystal phoswich detector for beta–gamma coincidence detection
    Xing Fan
    Xian-Peng Zhang
    Geng Tian
    Chao-Wen Yang
    NuclearScienceandTechniques, 2018, 29 (04) : 48 - 53