Electron paramagnetic resonance dosimetry: Methodology and material characterization

被引:0
|
作者
Hayes, RB [1 ]
机构
[1] Univ Utah, Coll Engn, Nucl Engn Program, Salt Lake City, UT 84112 USA
关键词
D O I
10.1118/1.598776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron paramagnetic resonance (EPR) methodologies for radiation dosimetry are investigated using various dosimeter materials. Specifically, methodologies were developed and used which were intended to improve the accuracy and precision of EPR dosimetric techniques, including combining specimen rotation during measurement, use of an internal manganese standard, instrument stabilization techniques, and strict measurement protocols. Characterization and quantification of these improvements were performed on three specific EPR dosimeter materials. The dosimeter materials investigated were walrus teeth, human tooth enamel, and alanine dosimeters. Walrus teeth showed the least desirable properties for EPR dosimetry yielding large native signals and low radiation sensitivity. The methods for tooth enamel and alanine resulted in large improvements in precision and accuracy. The minimum detectable dose (MDD) found for alanine was approximately 30 mGy (three standard deviations from the measured zero dose value). This is a sensitivity improvement of 5 to 10 over other specialized techniques published in the literature that offer MDDs in the range of 150–300 mGy. The accuracy of the method on tooth-enamel was comparable to that typically reported in the literature although the measurement precision was increased by about 7. This improvement in measurement precision enabled a more nondestructive testing evaluation procedure to be developed (where the whole sample need not be additively irradiated in order to calibrate its radiation sensitivity). Using this virtually nondestructive evaluation procedure on numerous samples showed that the method could reconstruct the same doses to within 10 mGy of those evaluated destructively. Doses used for this assessment were in the range of 100–250 mGy. © 1999, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2516 / 2516
页数:1
相关论文
共 50 条
  • [42] Optimisation of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry
    Ivannikov, AI
    Trompier, F
    Gaillard-Lecanu, E
    Skvortsov, VG
    Stepanenko, VF
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 531 - 538
  • [43] ELECTRON PARAMAGNETIC RESONANCE
    ERSKINE, F
    AMERICAN JOURNAL OF PHYSICS, 1965, 33 (04) : 356 - &
  • [44] ELECTRON PARAMAGNETIC RESONANCE
    不详
    CURRENT SCIENCE, 1965, 34 (19): : 568 - &
  • [45] ELECTRON PARAMAGNETIC RESONANCE
    OBRIEN, RF
    AMERICAN SCIENTIST, 1965, 53 (02) : A221 - &
  • [46] ELECTRON PARAMAGNETIC RESONANCE
    EARGLE, DH
    ANALYTICAL CHEMISTRY, 1968, 40 (05) : R303 - &
  • [47] ELECTRON PARAMAGNETIC RESONANCE
    EARGLE, DH
    ANALYTICAL CHEMISTRY, 1966, 38 (05) : R371 - +
  • [48] ELECTRON PARAMAGNETIC RESONANCE
    EHRENBER.A
    SVENSK KEMISK TIDSKRIFT, 1965, 77 (04): : 229 - &
  • [49] Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites
    Desmet, Celine M.
    Djurkin, Andrej
    Dos Santos-Goncalvez, Ana Maria
    Dong, Ruhong
    Kmiec, Maciej M.
    Kobayashi, Kyo
    Rychert, Kevin
    Beun, Sebastien
    Leprince, Julian G.
    Leloup, Gaetane
    Leveque, Philippe
    Gallez, Bernard
    PLOS ONE, 2015, 10 (06):
  • [50] Optimisation of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry
    Ivannikov, AI
    Trompier, F
    Gaillard-Lecanu, E
    Skvortsov, VG
    Stepanenko, VF
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A531 - A538