I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury

被引:7
|
作者
Abiko, Kagari [1 ]
Ikoma, Katsunori [1 ]
Shiga, Tohru [2 ]
Katoh, Chietsugu [2 ]
Hirata, Kenji [2 ]
Kuge, Yuji [3 ]
Kobayashi, Kentaro [2 ]
Tamaki, Nagara [2 ]
机构
[1] Hokkaido Univ Hosp, Dept Rehabil Med, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Dept Nucl Med, Sch Med, Kita Ku, North 15th,West 7th, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Dept Tracer Kinet, Sapporo, Hokkaido 0608638, Japan
来源
EJNMMI RESEARCH | 2017年 / 7卷
关键词
NONMISSILE HEAD-INJURY; BENZODIAZEPINE-RECEPTORS; AXONAL INJURY; BLOOD-FLOW; RO; 15-1788; BINDING; SPECT; PET; HYPOMETABOLISM; SCATTER;
D O I
10.1186/s13550-017-0276-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whether IMZ SPECT is as useful as FMZ PET for evaluating the loss of neuronal integrity in TBI patients. The subjects of this study were seven patients who suffered from neurobehavioral disability. They underwent IMZ SPECT and FMZ PET. Nondisplaceable binding potential (BPND) was calculated from FMZ PET images. The uptake of IMZ was evaluated on the basis of lesion-to-pons ratio (LPR). The locations of low uptake levels were visually evaluated both in IMZ SPECT and FMZ PET images. We compared FMZ BPND and (LPR-1) of IMZ SPECT. Results: In the visual assessment, FMZ BPND decreased in 11 regions. In IMZ SPECT, low uptake levels were observed in eight of the 11 regions. The rate of concordance between FMZ PET and IMZ SPECT was 72.7%. The mean values IMZ (LPR-1) (1.95 +/- 1.01) was significantly lower than that of FMZ BPND (2.95 +/- 0.80 mL/mL). There was good correlation between FMZ BPND and IMZ (LPR-1) (r = 0.80). Conclusions: IMZ SPECT findings were almost the same as FMZ PET findings in TBI patients. The results indicated that IMZ SPECT is useful for evaluating the loss of neuronal integrity. Because IMZ SPECT can be performed in various facilities, IMZ SPECT may become widely adopted for evaluating the loss of neuronal integrity.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Quantitative analysis of 123I-iomazenil single-photon emission computed tomography findings from patients with infantile epileptic spasm syndrome
    Takeuchi, Hirokazu
    Kikuchi, Kenjiro
    Takeda, Rikako
    Hirata, Yuko
    Matsuura, Ryuki
    Koichihara, Reiko
    Hamano, Shin-ichiro
    BRAIN & DEVELOPMENT, 2025, 47 (01):
  • [22] GABA(A) RECEPTOR CHANGES IN SCHIZOPHRENIA IS ASSESSED USING I-123 IOMAZENIL SINGLE-PHOTON EMISSION TOMOGRAPHY (SPET) - A PRELIMINARY-REPORT
    BUSATTO, GF
    PILOWSKY, LS
    COSTA, DC
    ELL, PJ
    KERWIN, RW
    SCHIZOPHRENIA RESEARCH, 1995, 15 (1-2) : 78 - 79
  • [23] Neuronal dysfunction and hemodynamic disturbance due to venous congestion in dural arteriovenous fistula revealed by 123I-iomazenil single-photon emission computed tomography
    Hashimoto, Koji
    Kanemaru, Kazuya
    Yoshioka, Hideyuki
    Wakai, Takuma
    Tateoka, Toru
    Horiuchi, Ryo
    Kinouchi, Hiroyuki
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [24] Impact of dopamine transporter single photon emission computed tomography imaging using I-123 ioflupane on diagnoses of patients with parkinsonian syndromes
    Bairactaris, C.
    Demakopoulos, N.
    Tripsianis, G.
    Sioka, C.
    Farmakiotis, D.
    Vadikolias, K.
    Heliopoulos, I.
    Georgoulias, P.
    Tsougos, I.
    Papanastasiou, I.
    Piperidou, C.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (02) : 246 - 252
  • [25] Neuronal Dysfunction And Hemodynamic Disturbance Due To Venous Congestion In Dural Arteriovenous Fistula Revealed By 123I-iomazenil Single-photon Emission Computed Tomography
    Kanemaru, Kazuya
    Yoshioka, Hideyuki
    Hashimoto, Koji
    Wakai, Takuma
    Tateoka, Toru
    Fukuda, Norito
    Kinouchi, Hiroyuki
    STROKE, 2023, 54
  • [26] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) WITH N-ISOPROPYL (I-123) IODOAMPHETAMINE IN STROKE
    SAXENA, VK
    COLLIER, DB
    TIKOFSKY, RS
    HELLMAN, RS
    CIRCULATION, 1985, 72 (04) : 256 - 256
  • [27] I-123 iofetamine single-photon computed emission tomography in rapid cycling bipolar disorder: A clinical study
    Gyulai, L
    Alavi, A
    Broich, K
    Reilley, J
    Ball, WB
    Whybrow, PC
    BIOLOGICAL PSYCHIATRY, 1997, 41 (02) : 152 - 161
  • [28] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY WITH I-123 IMP IN 3 CASES OF THE NEUROLEPTIC MALIGNANT SYNDROME
    NISIJIMA, K
    MATOBA, M
    ISHIGURO, T
    NEURORADIOLOGY, 1994, 36 (04) : 281 - 284
  • [29] IOFETAMINE I-123 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IS ACCURATE IN THE DIAGNOSIS OF ALZHEIMERS-DISEASE
    JOHNSON, KA
    HOLMAN, BL
    ROSEN, TJ
    NAGEL, JS
    ENGLISH, RJ
    GROWDON, JH
    ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (04) : 752 - 756
  • [30] Iomazenil-single-photon emission computed tomography reveals selective neuronal loss in magnetic resonance-defined mismatch areas
    Saur, Dorothee
    Buchert, Ralph
    Knab, Rene
    Weiller, Cornelius
    Roether, Joachim
    STROKE, 2006, 37 (11) : 2713 - 2719