Objectives: To test the effect of altering image size on diagnostic quality. Methods: Endodontic files, size 10 and 15 were prepared to full root length and 1.5 mm short, in upper and lower molars and premolars. Digital images of the Sidexis (S) and Visualix/Vixa (V) system were reduced in size to Digora (D) scale, and the D images were enlarged to S scale. ROC analysis was performed and data analysed with MANOVA statistics. Results: Assessment of root canal length with file size 10 was less accurate for the S images reduced in size, compared with the original S images (P < 0.011). All other differences were not significant (P > 0.081). Conclusions: Relevant diagnostic information may be lost when images are reduced in size. Therefore, for optimal presentation, the smaller images should be enlarged rather than the larger ones reduced.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [21] Comparison of dedicated digital specimen radiography with direct digital specimen mammography images
    JC Morel
    V Milnes
    A Iqbal
    MJ Michell
    Breast Cancer Research, 13
  • [22] Comparison of dedicated digital specimen radiography with direct digital specimen mammography images
    Morel, J. C.
    Milnes, V.
    Iqbal, A.
    Michell, M. J.
    BREAST CANCER RESEARCH, 2011, 13
  • [23] Investigation of noise sources for digital radiography systems
    Ergun L.
    Olgar T.
    Radiological Physics and Technology, 2017, 10 (2) : 171 - 179
  • [24] Quality assurance of computed and digital radiography systems
    Walsh, C.
    Gorman, D.
    Byrne, P.
    Larkin, A.
    Dowling, A.
    Malone, J. F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 271 - 275
  • [25] Comparison of Digital Imaging Systems for Neutron Radiography
    Pugliesi, R.
    Pugliesi, Fabio
    Stanojev Pereira, M. A.
    BRAZILIAN JOURNAL OF PHYSICS, 2011, 41 (2-3) : 123 - 128
  • [26] Digital detection systems for projection radiography.
    Schulz, RF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (12): : 1137 - 1146
  • [27] THE VALUE OF DIGITAL RADIOGRAPHY SYSTEMS IN SKELETAL IMAGING
    LEHMANN, KJ
    BUSCH, HP
    SOMMER, A
    GEORGI, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (03): : 286 - 291
  • [28] Application of the ALARA Principle in Digital Radiography Systems
    Brindhaban, A.
    Abdulwahab, F.
    Essa, F.
    Tariq, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Comparison of Digital Imaging Systems for Neutron Radiography
    R. Pugliesi
    Fábio Pugliesi
    M. A. Stanojev Pereira
    Brazilian Journal of Physics, 2011, 41 : 123 - 128
  • [30] An overview of digital imaging systems for radiography and fluoroscopy
    Yester, Michael V.
    Specifications Performance Evaluation and Quality Assurance of Radiographic and Fluoroscopic Systems in the Digital Era, 2006, (30): : 143 - 152