Glucose concentration monitoring using a small Fabry-Perot etalon

被引:2
|
作者
Martini, Joerg [1 ]
Kiesel, Peter [1 ]
Roe, Jeffrey [1 ]
Bruce, Richard H. [1 ]
机构
[1] Palo Alto Res Ctr, Hardware Syst Lab, Palo Alto, CA 94304 USA
关键词
refractive index; etalon; glucose detection; diabetes; continuous glucose monitoring (CGM); analyte assay; medical implant; vertical-cavity surface-emitting laser (VCSEL); CONCANAVALIN-A; REFRACTOMETRY; HYPOGLYCEMIA; BINDING; INSULIN; SENSOR;
D O I
10.1117/1.3153848
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate measurements of aqueous glucose concentrations have been made in a double-chamber Fabry-Perot etalon that can be miniaturized for subcutaneous implantation to determine the concentration of glucose in interstitial fluid. In general, optical approaches to glucose detection measure light intensity, which in tissue varies due to inherent scattering and absorption. In our measurements, we compare the spectral positions of transmission maximums in two adjunct sections of an etalon in order to determine the refractive index difference between these sections and therefore we can tolerate large changes in intensity. With this approach, we were able to determine aqueous glucose concentrations between 0 mg/dl and 700 mg/dl within the precision of our reference measurement (+/- 2.5 mg/dl or 2% of the measurement value). The use of reference cavities eliminates interference due to temperature variations, and we show the temperature independence over a temperature range of 32 degrees C to 42 degrees C. Furthermore, external filters eliminate interference from large molecule contaminants. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3153848]
引用
收藏
页数:8
相关论文
共 50 条
  • [41] CRYOGENIC FAR-INFRARED FABRY-PEROT ETALON
    PETERSON, DB
    PICKETT, HM
    APPLIED OPTICS, 1991, 30 (31): : 4493 - 4495
  • [42] FEMTOSECOND RESPONSE OF A SEMICONDUCTOR NONLINEAR FABRY-PEROT ETALON
    PAYE, J
    HULIN, D
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1993, 10 (12) : 2371 - 2376
  • [43] Secondary spectral standards based on Fabry-Perot etalon
    Chountonov, G. A.
    ASTROPHYSICAL BULLETIN, 2011, 66 (04) : 496 - 498
  • [44] USE OF REFLECTED LIGHT IN THE WORK WITH A FABRY-PEROT ETALON
    ODINTSOV, VI
    OPTIKA I SPEKTROSKOPIYA, 1961, 11 (04): : 553 - 555
  • [45] Fabry-Perot etalon solved by an amplitude and phase approach
    Jimenez Romero, H. A.
    Fernandez-Guasti, M.
    OPTIK, 2019, 185 : 397 - 404
  • [46] MAXIMUM ATTAINABLE RESOLUTION OF A REAL FABRY-PEROT ETALON
    ANANEV, YA
    OPTICS AND SPECTROSCOPY-USSR, 1966, 20 (01): : 89 - &
  • [47] High precision testing method for Fabry-Perot etalon
    Itoh, S
    Yamazaki, Y
    Katoh, K
    Chen, J
    OPTICAL REVIEW, 2001, 8 (03) : 179 - 183
  • [48] Influence of a Fabry-Perot etalon on a chirped optical pulse
    Wu, ZM
    Xia, GQ
    Chen, JG
    Liu, L
    OPTICS AND LASER TECHNOLOGY, 2001, 33 (07): : 471 - 473
  • [49] THERMAL STIMULATED RADIATION OF A DISSIPATIVE FABRY-PEROT ETALON
    PASTRNAK, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1967, 17 (08) : 666 - &
  • [50] Measuring the etalon quality of the GREGOR Fabry-Perot interferometer
    Verma, Meetu
    Denker, Carsten
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2020, 6 (01)