Zero-sequence voltage trajectory analysis for unbalanced distribution networks on single-line-to-ground fault condition

被引:27
|
作者
Meng, Jun [1 ]
Wang, Wen [2 ]
Tang, Xin [2 ]
Xu, Xianyong [3 ]
机构
[1] Cent S Univ, Sch Business, Changsha, Hunan, Peoples R China
[2] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha, Hunan, Peoples R China
[3] Hunan Elect Power Corp Res Inst, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Distribution power system; Single-phase-to-ground fault; Faulty phase recognition; High-resistance ground fault; Distribution network asymmetry; Zero-sequence voltage; PETERSEN-COIL CONTROL; TEMPORARY OVERVOLTAGES; MV NETWORKS;
D O I
10.1016/j.epsr.2018.03.024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Faulty phase recognition under single-line-to-ground (SLG) fault condition is critical for some arc suppression methods in medium voltage (MV) networks. Traditional methods usually assume that the distributed parameters of the network are symmetrical, thus are unsuitable for the asymmetrical networks, especially when the ground-fault resistance is relatively high. In this paper, the trajectory of the zero-sequence voltage with the change of ground-fault conductance is analyzed in detail. The magnitude and phase angle variation rules of the voltage under different asymmetry ratios are presented. Then, the ranges of their unique variation rules on SLG fault for each phases are separately and strictly discussed both for the under-compensated and over-compensated grounding conditions. Furthermore, a faulty phase recognition method is proposed based on the variation rules of zero-sequence voltage on faulty condition. Simulation results verify the concluded variation rules and validate the effectiveness of the proposed fault phase recognition method, which ensures exact recognition of faulty phase in asymmetrical network and high-resistance ground fault condition. (C) 2018 The Author(s). Published by Elsevier B.V.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [31] Digital simulation for zero-sequence voltage of large hydro-generator during stator ground fault
    Tai, Nengling
    Yin, Xianggen
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2000, 24 (09): : 19 - 22
  • [32] Digital simulation for zero-sequence voltage of large hydro-generator during stator ground fault
    Tai, Nengling
    Yin, Xianggen
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2000, 24 (09):
  • [33] Principle of Flexible Ground-Fault Arc Suppression Device Based on Zero-Sequence Voltage Regulation
    Fan, Bishuang
    Yao, Ganzhou
    Yu, Kun
    Zeng, Xiangjun
    Wang, Wen
    Zhuo, Chao
    Guerrero, Josep M.
    IEEE ACCESS, 2021, 9 : 2382 - 2389
  • [34] Identification Method for Single-line-to-ground Faults with Line Break Based on Phasor Measurement in Distribution Networks
    Yadong Liu
    Zichang Li
    Yingjie Yan
    Guanghui He
    Jian Fang
    Kejun Li
    Xiuchen Jiang
    JournalofModernPowerSystemsandCleanEnergy, 2023, 11 (03) : 907 - 916
  • [35] Identification Method for Single-line-to-ground Faults with Line Break Based on Phasor Measurement in Distribution Networks
    Liu, Yadong
    Li, Zichang
    Yan, Yingjie
    He, Guanghui
    Fang, Jian
    Li, Kejun
    Jiang, Xiuchen
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (03) : 907 - 916
  • [36] Phase selection method of single line to ground fault in unbalanced distribution network based on ground fault ratio
    Sun Z.
    Xu H.
    Zhu H.
    Bian C.
    Yu D.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (12): : 108 - 116
  • [37] Performance of a self-commutated BTB HVDC link system under a single-line-to-ground fault condition
    Hagiwara, M
    Fujita, H
    Akagi, H
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (01) : 278 - 285
  • [38] A Principle of Fault Line Selection Based on Increasing Zero-sequence Current in Non-ground Neutral System
    Huang, Tantan
    Zhang, Huifen
    Gao, Zhipeng
    Guo, Yao
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2052 - 2056
  • [39] The research on directional elements of high-voltage line protections based on zero-sequence reactance of fault components
    Zeng, Xiaohui
    Chen, Yonghui
    Song, Hong
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 511 - 515
  • [40] Single-phase grounding fault line selection method based on zero-sequence current increment
    Hao, Bai
    ENERGY REPORTS, 2022, 8 : 305 - 312