Development and evaluation of a rapid neutralizing antibody test for rabies

被引:32
|
作者
Shiota, Seiji [1 ]
Mannen, Kazuaki [2 ]
Matsumoto, Takashi [1 ]
Yamada, Kentaro [2 ]
Yasui, Takehito [3 ]
Takayama, Katsuyoshi [3 ]
Kobayashi, Yukuharu [3 ]
Khawplod, Pakamatz [4 ]
Gotoh, Kazuyo [2 ]
Ahmed, Kamruddin [2 ]
Iha, Hidekatsu [1 ]
Nishizono, Akira [1 ,2 ]
机构
[1] Oita Univ, Fac Med, Dept Microbiol, Yufu, Oita 8795593, Japan
[2] Oita Univ, Dept Social & Environm Med, Inst Sci Res, Div Infect Dis, Yufu, Oita 8795593, Japan
[3] Adtec Co Ltd, Div Res & Dev, Oita 8790471, Japan
[4] Thai Red Cross Soc, Queen Saovabha Mem Inst, Bangkok 10330, Thailand
关键词
Glycoprotein; Immunochromatography; Rabies vaccine; Rabies virus; Virus-neutralizing antibody; VIRUS; ELISA; GLYCOPROTEIN; VACCINATION;
D O I
10.1016/j.jviromet.2009.05.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The level of virus-neutralizing antibody, which plays a crucial role in the prevention of rabies, is determined by rabiesviruis (RABV) neutralizing test, which are time- and cost-consuming. In order to determine the level of neutralizing antibody in vaccinees, an easy and reliable method is needed. Based on the principle of immunochromatography, we developed a RAPINA (RAPId Neutralizing Antibody) test to determine the presence of neutralizing antibody in serum. In the RAPINA test, if neutralizing antibody equivalent to 0.5 IU/ml of serum sample are mixed with an optimal amount of inactivated RABV (iRABV) and are completely absorbed by the virus, none of the iRABV can bind with monoclonal antibody that recognizes the iRABV glycoprotein (G) on the test strip. A total of 115 human sera samples were tested. The sensitivity, specificity and accuracy of the RAPINA test compared with rapid fluorescent focus inhibition test (RFFIT) as a standard test, were 88.7, 91.9 and 90.4%, respectively. The RAPINA test is a simple, safe and rapid method, which can be a substitute for neutralizing tests that use live viruses, cultured cells and fluorescence microscopy. This test might be useful for screening a large number of sera. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 62
页数:5
相关论文
共 50 条
  • [31] NEUTRALIZING ANTIBODY-LEVELS IN CATTLE VACCINATED AGAINST RABIES
    ROEHE, PM
    CUNHA, AC
    KING, A
    PESQUISA VETERINARIA BRASILEIRA, 1987, 7 (03): : 63 - 65
  • [32] FLUORESCENT RABIES ANTIBODY-TEST
    FREDRICKSON, LE
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1974, 164 (08): : 778 - 779
  • [33] A RABIES AGGLUTINATION-TEST (RAT) FOR RABIES ANTIBODY DETECTION
    PERRIN, P
    VERSMISSE, P
    SUREAU, P
    JOURNAL OF BIOLOGICAL STANDARDIZATION, 1988, 16 (04): : 281 - &
  • [34] Evaluation of rabies virus neutralizing antibody titres induced by intramuscular inoculation of rabies DNA vaccine in mice and Bonnet monkeys (Macaca radiata)
    Biswas, S.
    Kalanidhi, A.P.
    Ashok, M.S.
    Reddy, G.S.
    Srinivasan, V.A.
    Rangarajan, P.N.
    Indian Journal of Experimental Biology, 2001, 39 (06) : 533 - 536
  • [35] Performance Evaluation of the BZ COVID-19 Neutralizing Antibody Test for the Culture-Free and Rapid Detection of SARS-CoV-2 Neutralizing Antibodies
    Jung, Bo Kyeung
    Yoon, Jung
    Bae, Joon-Yong
    Kim, Jeonghun
    Park, Man-Seong
    Lee, Suk Yong
    Lim, Chae Seung
    DIAGNOSTICS, 2021, 11 (12)
  • [36] Chicken embryo related (CER) cell line for quantification of rabies neutralizing antibody by fluorescent focus inhibition test
    Cardoso, TC
    da Silva, LHQ
    da Silva, SEL
    Albas, A
    Pardo, PE
    Tanaka, AH
    Cossy, LB
    Perri, SHV
    BIOLOGICALS, 2006, 34 (01) : 29 - 32
  • [37] Development and evaluation of a competitive ELISA for estimation of rabies neutralizing antibodies after post-exposure rabies vaccination in humans
    Muhamuda, Kader
    Madhusudana, Shampur Narayan
    Ravi, Vasanthapuram
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2007, 11 (05) : 441 - 445
  • [38] A preliminary evaluation of a locally produced biotinylated polyclonal anti-rabies antibody for direct rapid immunohistochemical test (DRIT) in the Philippines
    Manalo, Daria L.
    Gomez, Ma Ricci R.
    Jarilla, Blanca R.
    Ang, Mary Jasmin C.
    Tuason, Laarni T.
    Demetria, Catalino S.
    Medina, Plebeian B.
    Dilig, Joselito E.
    Avenido-Cervantes, Eleonor F.
    Park, Chun-Ho
    Inoue, Satoshi
    ACTA TROPICA, 2020, 211
  • [39] EVALUATION OF INTERFERENCE FILTER FOR USE IN RABIES DIAGNOSIS BY FLUORESCENT-ANTIBODY TEST
    LEWIS, VJ
    THACKER, WL
    ENGELMAN, HM
    APPLIED MICROBIOLOGY, 1973, 26 (03) : 429 - 430
  • [40] Rapid Rabies Antibody Response after Priming Dose of Rabies Vaccine
    Suandork, Pomtep
    Suntarattiwong, Piyasat
    Prommalikit, Olam
    Kumperasart, Sanit
    Sungdee, Araya
    Pattamadilok, Sirima
    Sawanpanyalert, Pathom
    Pancharoen, Chitsanu
    Thisyakorn, Usa
    Wilde, Henry
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2005, 26 : S84 - S84