Effect of induced pressure fluctuation in reservoir of a pulse tube cryocooler

被引:1
|
作者
Abraham, Derick [1 ]
Kuzhiveli, Biju T. [1 ]
机构
[1] Natl Inst Technol Calicut, CASC, Calicut 673601, Kerala, India
关键词
D O I
10.1088/1757-899X/502/1/012046
中图分类号
O59 [应用物理学];
学科分类号
摘要
Pulse Tube Cryocoolers are used extensively in aerospace applications, environmental studies, and medical applications. It has several advantages of which some are very low vibration and long life. The performance of Pulse tube cryocooler can be enhanced by using a combination of inertance tube and reservoir. For practical applications the pulse tube cryocooler should be compact in size. This could be achieved by reducing the volume of the reservoir. This paper analyses the feasibility of introducing a reverse fluctuation inside the reservoir to minimize reservoir volume. Reverse fluctuation could be introduced by using the back volume of hermetically sealed linear compressor. To ascertain the same a numerical model was developed and simulated using Ansys Fluent. The effect of pressure variation in the reservoir and its equivalent performance was also simulated. The results suggest that the use of bounce space has a better results at lower volume and equivalent performance on increasing volume when compared to the cryocooler with reservoir.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Reversible cycle piston pulse tube cryocooler
    Johnson, AL
    CRYOCOOLERS 9, 1997, : 309 - 318
  • [32] Conducted EMI Reduction on the Pulse Tube Cryocooler
    Eshraghi, M. J.
    Cho, Myongwon
    Kim, Jin Mok
    Sasada, Ichiro
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (06) : 2754 - 2757
  • [33] Raytheon Stirling/pulse tube cryocooler development
    Kirkeonnell, C. S.
    Hon, R. C.
    Kesler, C. H.
    Roberts, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 909 - +
  • [34] PULSE TUBE REFRIGERATION - A NEW TYPE OF CRYOCOOLER
    RADEBAUGH, R
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 : 2076 - 2081
  • [35] Intermediate cooling from pulse tube and regenerator in a 4 K pulse tube cryocooler
    Wang, Chao
    CRYOGENICS, 2008, 48 (3-4) : 154 - 159
  • [36] A study of performance improvement of the coaxial inertance tube pulse tube cryocooler
    Park, SJ
    Hong, YJ
    Kim, HB
    Kim, YH
    CRYOCOOLERS 13, 2005, : 261 - 266
  • [37] Experimental study of a 4 K pulse tube cryocooler
    Fujimoto, S
    Kurihara, T
    Oodo, T
    Kang, YM
    Numazawa, T
    Matsubara, Y
    CRYOCOOLERS 11, 2001, : 213 - 219
  • [38] A study on the in-line type inertance tube pulse tube cryocooler
    Park, Seong-Je
    Koh, Deuk-Yong
    Hong, Yong-Ju
    Kim, Hyo-Bong
    Kini, Seon-Young
    Jung, Woo-Seok
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 217 - 220
  • [39] The third type DC flow in pulse tube cryocooler
    Zhou Yuan
    Gu Chao
    Cai HuiKun
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2009, 52 (12): : 3491 - 3496
  • [40] Experimental verification of a thermodynamic model for a pulse tube cryocooler
    Yuan, J
    Pfotenhauer, JM